| Literature DB >> 26508105 |
Amandine Magnette1, Te-Din Huang2, Francesco Renzi3, Pierre Bogaerts1, Guy R Cornelis3, Youri Glupczynski1.
Abstract
Capnocytophaga canimorsus and Capnocytophaga cynodegmi can be transmitted from dogs or cats and cause serious human infections. We aimed to evaluate the ability of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) to identify these two Capnocytophaga species. Ninety-four C. canimorsus and 10 C. cynodegmi isolates identified by 16S rRNA gene sequencing were analyzed. Using the MALDI BioTyper database, correct identification was achieved for only 16 of 94 (17%) C. canimorsus and all 10 C. cynodegmi strains, according to the manufacturer's log score specifications. Following the establishment of a complementary homemade reference database by addition of 51 C. canimorsus and 8 C. cynodegmi mass spectra, MALDI-TOF MS provided reliable identification to the species level for 100% of the 45 blind-coded Capnocytophaga isolates tested. MALDI-TOF MS can accurately identify C. canimorsus and C. cynodegmi using an enriched database and thus constitutes a valuable diagnostic tool in the clinical laboratory.Entities:
Keywords: Capnocytophaga; Capnocytophaga canimorsus; Capnocytophaga cynodegmi; Database; MALDI-TOF MS; Rapid identification
Mesh:
Substances:
Year: 2015 PMID: 26508105 DOI: 10.1016/j.diagmicrobio.2015.09.016
Source DB: PubMed Journal: Diagn Microbiol Infect Dis ISSN: 0732-8893 Impact factor: 2.803