Literature DB >> 26507695

Accuracy of Spleen Measurement by Medical Residents Using Hand-Carried Ultrasound.

Shane Arishenkoff1, Christopher Eddy1, J Mark Roberts1, Luke Chen1, Silvia Chang1, Parvathy Nair1, Rose Hatala1, Kevin W Eva1, Graydon S Meneilly2.   

Abstract

OBJECTIVES: Easily palpable splenomegaly can be identified on physical examination, but it is difficult to detect lesser degrees of splenomegaly. Rapid bedside assessment can be conducted with hand-carried ultrasound. We performed this study to determine whether medical residents could reliably assess spleen size using hand-carried ultrasound after a brief educational intervention.
METHODS: Postgraduate year 1 internal medicine residents were shown a brief (45-minute) presentation on ultrasound basics, the use of hand-carried ultrasound, and principles of splenic ultrasound imaging. They practiced on each other, using hand-carried ultrasound to assess spleen size, for 1 hour in the presence of an instructor. Patients with varying degrees of splenomegaly and hospital staff were recruited at Vancouver General Hospital. A sonographer measured spleen size in each participant using conventional ultrasound. Subsequently, the trained residents scanned the participants using hand-carried ultrasound, blinded to the sonographer's measurements and the participants' diagnoses. The instructor was not present during scanning.
RESULTS: Twelve first-year residents (8 male and 4 female; mean age ± SEM, 28 ± 1 years; all with limited prior ultrasound training) and 19 patients and staff members (10 male and 9 female; mean age, 60 ± 4 years; body mass index, 24 ± 2 kg/m(2)) were recruited. The greatest longitudinal measurements were 14.0 ± 0.7 cm with conventional ultrasound administered by the sonographer and 13.2 ± 0.9 cm with hand-carried ultrasound administered by the residents (P > .05, not significant). The correlation between conventional and hand-carried ultrasound was r = 0.81 (P < .001).
CONCLUSIONS: Internal medicine residents can reliably assess spleen size at the point of care using hand-carried ultrasound with minimal training. Our findings, if replicated in other centers and in different clinical scenarios, may change the way that clinicians examine the spleen.
© 2015 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  Vscan; hand-carried ultrasound; spleen; ultrasound; ultrasound education

Mesh:

Year:  2015        PMID: 26507695     DOI: 10.7863/ultra.15.02022

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Internal Medicine Point-of-Care Ultrasound Curriculum: Consensus Recommendations from the Canadian Internal Medicine Ultrasound (CIMUS) Group.

Authors:  Irene W Y Ma; Shane Arishenkoff; Jeffrey Wiseman; Janeve Desy; Jonathan Ailon; Leslie Martin; Mirek Otremba; Samantha Halman; Patrick Willemot; Marcus Blouw
Journal:  J Gen Intern Med       Date:  2017-05-11       Impact factor: 5.128

2.  Postprandial dynamics of splenic volume in healthy volunteers.

Authors:  Lydia Garnitschnig; Johannes Weinzirl; Lukas Andrae; Tom Scheffers; Thomas Ostermann; Peter Heusser
Journal:  Physiol Rep       Date:  2020-01

3.  [Usefulness and reliability of abdominal point of care ultrasound in family practice (2): Large abdominal vessels, spleen, nephrourological and gynecological ultrasound].

Authors:  Ignacio Manuel Sánchez Barrancos; Francisco José Guerrero García; María Del Carmen Rico López; Vicente Fernández Rodríguez; Tomás Vegas Jiménez; Rafael Alonso Roca; Daniel Domínguez Tristancho
Journal:  Aten Primaria       Date:  2018-05-30       Impact factor: 1.137