Abstract
Criteria for objective assessment of cobalt-chromium castings have been developed. A random sample of 21 commercial dental laboratories specialising in the production of cobalt-chromium castings was selected. Identical casts and instructions for the construction of a lower partial denture framework were sent to each of them. The resultant castings were assessed according to specific criteria relating to detailed design features. Only one laboratory produced a casting which conformed completely with the design instructions. Significant defects were found in a high proportion of castings. The range of charges was from 28 pounds to 85 pounds. The results of the qualitative assessments suggest only a very weak relationship between laboratory charges and the quality of cobalt-chromium castings. Suggestions are made for minimum standards that may be applied in clinical practice.Entities:
Mesh:
Substances:
Year: 1989 PMID: 2650726 DOI: 10.1038/sj.bdj.4806764