Color-flow Doppler and conventional duplex scanning of the carotid bifurcation: prospective, double-blind, correlative study.

M J Hallam1, J M Reid, P L Cooperberg.   

Abstract

Color-flow Doppler is a useful adjunct in duplex sonography of peripheral vessels. This study was undertaken to see if color-flow Doppler could give semiquantitative information about the degree of stenosis at the origin of the internal carotid artery. The factors evaluated on color flow are the width of the lumen as estimated from the color-flow image relative to the width of the vessel, the degree of turbulence (evidenced by the mosaic pattern), and the pulse-repetition frequency necessary to prevent aliasing. A double-blind comparison with conventional duplex scanning in 146 carotid bifurcations in 74 patients was carried out. In 91%, the color-flow assessment was in complete agreement with the duplex assessment. In the remaining 9%, the color flow differed from the duplex by only one stenosis group, and the distributions of over- and under-estimation were equal. These results showed comparable assessment of the degree of stenosis with conventional duplex and color Doppler technology.

Entities:  

Mesh:

Year:  1989        PMID: 2650482     DOI: 10.2214/ajr.152.5.1101

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Colour Doppler and duplex sonography and angiography of the carotid artery bifurcations. Prospective, double-blind study.

Authors:  J M Bray; F Galland; P Lhoste; S Nicolau; F Dubas; J Emile; J Pillet
Journal:  Neuroradiology       Date:  1995-04       Impact factor: 2.804

2.  Colour-coded Doppler sonography of common carotid artery dissection.

Authors:  S Trattnig; T Rand; M Thurnher; M Breitenseher; K Daha
Journal:  Neuroradiology       Date:  1995-02       Impact factor: 2.804

Review 3.  The role of imaging in the management of cerebral and ocular ischaemia.

Authors:  G J Hankey; C P Warlow
Journal:  Neuroradiology       Date:  1991       Impact factor: 2.804

4.  Differentiating subtotal carotid artery stenoses from occlusions by colour-coded duplex sonography.

Authors:  M Görtler; R Niethammer; B Widder
Journal:  J Neurol       Date:  1994-03       Impact factor: 4.849

5.  Simplified ultrasound protocol for the exclusion of clinically significant carotid artery stenosis.

Authors:  Dominika Högberg; Demosthenes Dellagrammaticas; Björn Kragsterman; Martin Björck; Anders Wanhainen
Journal:  Ups J Med Sci       Date:  2016-07-05       Impact factor: 2.384

  5 in total