Late leakage from four-branch prosthetic graft after total aortic arch repair.

Arudo Hiraoka1, Genta Chikazawa2, Taichi Sakaguchi2, Hidenori Yoshitaka2.   

Abstract

We present two cases with late graft leakage of unknown aetiology after open total aortic arch repair (TAR). Case 1: a 73-year-old woman underwent TAR for arch aneurysm with 24-mm four-branch graft. She had a previous history of pacemaker implantation for sick sinus syndrome and warfarin therapy for atrial fibrillation. Follow-up computed tomography (CT) revealed increased low-density area around the graft 4 years after surgery and blood leakage was shown in delayed-phase CT. Thoracic endovascular aortic repair (TEVAR) was performed to cover the haematic leakage, and shrinkage of the lesion was achieved 1 month after TEVAR. Case 2: a 72-year-old man with diabetes mellitus, hypertension and hyperlipidaemia was admitted to our institute for treatment of aortic arch aneurysm. TAR was successfully performed; however, leakage from the prosthetic graft was noticed by expert radiologists in follow-up delayed-phase CT scan 6 years after surgery. The leakage was resolved 1 month after TEVAR. Although the cause of late leakage was not determined, the slowly expanding haematoma proved to be treatable by additional TEVAR.
© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Haematic graft leakage; Prosthetic graft; Thoracic endovascular aortic repair; Total aortic arch repair

Mesh:

Year:  2015        PMID: 26503728     DOI: 10.1093/ejcts/ezv360

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  1 in total

1.  Complete neck vessel preservation using a fenestrated stent graft for the treatment of proximal anastomotic leakage after open frozen elephant trunk graft aortic arch repair.

Authors:  Hikaru Nakagawa; Takao Ohki; Naoki Toya; Eisaku Ito; Tadashi Akiba
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-01-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.