Ahmed Mohyeldin1, Russell R Lonser1, J Bradley Elder1. 1. Department of Neurological Surgery, The Ohio State University Wexner Medical Center, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus, Ohio.
Abstract
OBJECTIVE: The object of this study was to assess the feasibility, accuracy, and safety of real-time MRI-compatible frameless stereotactic brain biopsy. METHODS: Clinical, imaging, and histological data in consecutive patients who underwent stereotactic brain biopsy using a frameless real-time MRI system were analyzed. RESULTS: Five consecutive patients (4 males, 1 female) were included in this study. The mean age at biopsy was 45.8 years (range 29-60 years). Real-time MRI permitted concurrent display of the biopsy cannula trajectory and tip during placement at the target. The mean target depth of biopsied lesions was 71.3 mm (range 60.4-80.4 mm). Targeting accuracy analysis revealed a mean radial error of 1.3 ± 1.1 mm (mean ± standard deviation), mean depth error of 0.7 ± 0.3 mm, and a mean absolute tip error of 1.5 ± 1.1 mm. There was no correlation between target depth and absolute tip error (Pearson product-moment correlation coefficient, r = 0.22). All biopsy cannulae were placed at the target with a single penetration and resulted in a diagnostic specimen in all cases. Histopathological evaluation of biopsy samples revealed dysembryoplastic neuroepithelial tumor (1 case), breast carcinoma (1 case), and glioblastoma multiforme (3 cases). CONCLUSIONS: The ability to place a biopsy cannula under real-time imaging guidance permits on-the-fly alterations in the cannula trajectory and/or tip placement. Real-time imaging during MRI-guided brain biopsy provides precise safe targeting of brain lesions.
OBJECTIVE: The object of this study was to assess the feasibility, accuracy, and safety of real-time MRI-compatible frameless stereotactic brain biopsy. METHODS: Clinical, imaging, and histological data in consecutive patients who underwent stereotactic brain biopsy using a frameless real-time MRI system were analyzed. RESULTS: Five consecutive patients (4 males, 1 female) were included in this study. The mean age at biopsy was 45.8 years (range 29-60 years). Real-time MRI permitted concurrent display of the biopsy cannula trajectory and tip during placement at the target. The mean target depth of biopsied lesions was 71.3 mm (range 60.4-80.4 mm). Targeting accuracy analysis revealed a mean radial error of 1.3 ± 1.1 mm (mean ± standard deviation), mean depth error of 0.7 ± 0.3 mm, and a mean absolute tip error of 1.5 ± 1.1 mm. There was no correlation between target depth and absolute tip error (Pearson product-moment correlation coefficient, r = 0.22). All biopsy cannulae were placed at the target with a single penetration and resulted in a diagnostic specimen in all cases. Histopathological evaluation of biopsy samples revealed dysembryoplastic neuroepithelial tumor (1 case), breast carcinoma (1 case), and glioblastoma multiforme (3 cases). CONCLUSIONS: The ability to place a biopsy cannula under real-time imaging guidance permits on-the-fly alterations in the cannula trajectory and/or tip placement. Real-time imaging during MRI-guided brain biopsy provides precise safe targeting of brain lesions.
Authors: Kristen E Malloy; Jinqi Li; Gourav R Choudhury; April Torres; Shruti Gupta; Chris Kantorak; Tim Goble; Peter T Fox; Geoffrey D Clarke; Marcel M Daadi Journal: Stem Cells Transl Med Date: 2016-09-22 Impact factor: 6.940
Authors: Birra R Taha; Christian R Osswald; Matthew Rabon; Carolina Sandoval Garcia; Daniel J Guillaume; Xiao Wong; Andrew S Venteicher; David P Darrow; Michael C Park; Robert A McGovern; Cornelius H Lam; Clark C Chen Journal: World Neurosurg X Date: 2021-12-16