A novel method for in-vivo evaluation of finger kinematics including definition of healthy motion patterns.

Jérôme Coupier1, Samir Hamoudi2, Sonia Telese-Izzi2, Véronique Feipel3, Marcel Rooze3, Serge Van Sint Jan2.   

Abstract

BACKGROUND: Despite recent progress in motion capture technology, such as stereophotogrammetry based on the tracking of markers set on the subject, it remains challenging to develop a complete protocol for in-vivo functional evaluation of the hand. The current practical problems regarding small anatomical segments, such as the fingers, are mainly due to the high concentration of markers in a relatively reduced volume.
METHODS: This paper proposes a novel procedure for hand functional analysis by analysing finger behaviour along the main displacement plane simultaneously with combined motions. The objective was two-fold. For one thing, a novel data collection protocol was implemented, which includes specific setting of the motion capture system and the development of finger marker clusters. The second purpose of this study was to create a reference database of a healthy sample for further clinical investigation. Twenty healthy volunteers took part in the study. Analytical motions (flexion/extension and abduction/adduction) of all five fingers were recorded.
FINDINGS: Results showed good correspondence with the literature. Specific kinematic behaviour of each analysed joint is reported. Statistically significant differences were found between the right and left sides of the subjects for the flexion/extension movement only, between the finger joints and between the fingers for all movements. No significant difference was found between genders. A validation protocol was performed, which proved the validity of the presented methodology.
INTERPRETATION: The protocol appears suitable for further use in motion analysis and for musculoskeletal modelling of the hand. It will also be considered for clinical application.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Analytical motion; Finger kinematics; Functional evaluation; Reference patterns

Mesh:

Year:  2015        PMID: 26490639     DOI: 10.1016/j.clinbiomech.2015.10.002

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

1.  Quantifying Soft Tissue Artefacts and Imaging Variability in Motion Capture of the Fingers.

Authors:  C D Metcalf; C Phillips; A Forrester; J Glodowski; K Simpson; C Everitt; A Darekar; L King; D Warwick; A S Dickinson
Journal:  Ann Biomed Eng       Date:  2020-02-19       Impact factor: 3.934

2.  Minimal detectable difference of the finger and wrist range of motion: comparison of goniometry and 3D motion analysis.

Authors:  Lisa Reissner; Gabriella Fischer; Renate List; William R Taylor; Pietro Giovanoli; Maurizio Calcagni
Journal:  J Orthop Surg Res       Date:  2019-06-10       Impact factor: 2.359

3.  Hand Measurement System Based on Haptic and Vision Devices towards Post-Stroke Patients.

Authors:  Katarzyna Koter; Martyna Samowicz; Justyna Redlicka; Igor Zubrycki
Journal:  Sensors (Basel)       Date:  2022-03-07       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.