Michele Diana1,2, Hameed Usmaan3, Andras Legnèr3, Liu Yu-Yin4,5, Antonio D'Urso4, Peter Halvax3, Yoshihiro Nagao3, Patrick Pessaux3, Jacques Marescaux4,3. 1. IRCAD, Institute for Research Against Cancer of the Digestive System, 1, Place de l'Hôpital, 67091, Strasbourg, France. michele.diana@ircad.fr. 2. IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France. michele.diana@ircad.fr. 3. IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France. 4. IRCAD, Institute for Research Against Cancer of the Digestive System, 1, Place de l'Hôpital, 67091, Strasbourg, France. 5. Department of General Surgery, Chang Gung Memorial Hospital, Linkou, Chang Gung University, Taoyuan, Taiwan.
Abstract
INTRODUCTION: Bile leakage is a serious complication occurring in up to 10 % of hepatic resections. Intraoperative detection of bile leakage is challenging, and concomitant blood oozing can mask the presence of bile. Intraductal dye injection [methylene blue or indocyanine green (ICG)] is a validated technique to detect bile leakage. However, this method is time-consuming, particularly in the laparoscopic setting. A novel narrow band imaging (NBI) modality (SPECTRA-A; Karl Storz, Tuttlingen, Germany) allows easy discrimination of the presence of bile, which appears in clear orange, by image processing. The aim of this experimental study was to evaluate SPECTRA-A ability to detect bile leakage. METHODS: Twelve laparoscopic partial hepatectomies were performed in seven pigs. The common bile duct was clipped distally and dissected, and a catheter was inserted and secured with a suture or a clip. Liver dissection was achieved with an ultrasonic cutting device. Dissection surfaces were checked by frequently switching on the SPECTRA filter to identify the presence of bile leakage. Intraductal ICG injection through the catheter was performed to confirm SPECTRA findings. RESULTS: Three active bile leakages were obtained out of 12 hepatectomies and successfully detected intraoperatively by the SPECTRA. There was complete concordance between NBI and ICG fluorescence detection. No active leaks were found in the remaining cases with both techniques. The leaking area identified was sutured, and SPECTRA was used to assess the success of the repair. CONCLUSIONS: The SPECTRA laparoscopic image processing system allows for rapid detection of bile leaks following hepatectomy without any contrast injection.
INTRODUCTION: Bile leakage is a serious complication occurring in up to 10 % of hepatic resections. Intraoperative detection of bile leakage is challenging, and concomitant blood oozing can mask the presence of bile. Intraductal dye injection [methylene blue or indocyanine green (ICG)] is a validated technique to detect bile leakage. However, this method is time-consuming, particularly in the laparoscopic setting. A novel narrow band imaging (NBI) modality (SPECTRA-A; Karl Storz, Tuttlingen, Germany) allows easy discrimination of the presence of bile, which appears in clear orange, by image processing. The aim of this experimental study was to evaluate SPECTRA-A ability to detect bile leakage. METHODS: Twelve laparoscopic partial hepatectomies were performed in seven pigs. The common bile duct was clipped distally and dissected, and a catheter was inserted and secured with a suture or a clip. Liver dissection was achieved with an ultrasonic cutting device. Dissection surfaces were checked by frequently switching on the SPECTRA filter to identify the presence of bile leakage. Intraductal ICG injection through the catheter was performed to confirm SPECTRA findings. RESULTS: Three active bile leakages were obtained out of 12 hepatectomies and successfully detected intraoperatively by the SPECTRA. There was complete concordance between NBI and ICG fluorescence detection. No active leaks were found in the remaining cases with both techniques. The leaking area identified was sutured, and SPECTRA was used to assess the success of the repair. CONCLUSIONS: The SPECTRA laparoscopic image processing system allows for rapid detection of bile leaks following hepatectomy without any contrast injection.
Entities:
Keywords:
Bile leakage; Bile leakage test; Fluorescence-guided surgery; Hepatectomy; Laparoscopic narrow band imaging; Near-infrared indocyanine green leak test
Authors: Michael B Wallace; Julia E Crook; Susan Coe; Vivian Ussui; Estela Staggs; Cristina Almansa; Mihir K Patel; Ernest Bouras; John Cangemi; Andrew Keaveny; Michael Picco; Douglas Riegert-Johnson Journal: Gastrointest Endosc Date: 2014-06-25 Impact factor: 9.427
Authors: Sangheun Lee; Chang Mo Moon; Yu Jin Kim; Jae Hee Cho; Hee Man Kim; Ki Joon Han; Hyeon Geun Cho; Seung Won Lee; Ha Eun Oh; Ji-Sun Song; Sang Yeop Yi; Nak-Hoon Son Journal: Hepatogastroenterology Date: 2013 Jul-Aug
Authors: Michael P Luciano; Jung-Man Namgoong; Roger R Nani; So-Hyun Nam; Choonghee Lee; Il Hyung Shin; Martin J Schnermann; Jaepyeong Cha Journal: Mol Pharm Date: 2019-06-21 Impact factor: 4.939