Fiber reinforced composites orthodontic retainers.

A Lucchese1, M Manuelli, L Bassani, P Albertini, G Matarese, L Perillo, G Gastaldi, E F Gherlone.   

Abstract

AIM: Retention is the phase of orthodontic treatment that attempts to hold teeth in their corrected positions after orthodontic therapy is completed. The aim of this study was to consider fiber-reinforced composites (FRC) as a possible alternative to conventional multistranded stainless steel wire for retention through SEM analysis.
METHODS: Two different FRC orthodontic retainers were investigated, i.e. Everstick® (Stick Tech Ltd, Turku, Finland) (type A, 24 samples), with a diameter of 0.76 mm made of glass fibers and a Young's modulus of elasticity of 28 gpa, and Ribbond® (Ribbond, Inc., Seattle, Washington, WA, USA) (type B, 24 samples), with ultra high molecular weight and with an high Young's modulus of elasticity by polyethylene fibers cold treated with plasma gas. Six groups were created: control groups A1 and B1, composed by 8 type A and 8 type B samples without impregnation and only with fluid resin before curing; groups A2 and B2, composed respectively by 8 type A and 8 type B samples impregnated with fluid resin Heliobond for 6 seconds; groups A3 and B3, composed respectively by 8 type A and 8 type B samples impregnated with fluid resin Heliobond for 6 minutes before curing.
RESULTS: Cross- and lengthwise SEM analysis of the sectioned samples made showed that fiber without impregnation with fluid resin, before curing, showed interwoven and straight directed cylindrical fibers. The SEM analysis denoted that the two types of fiber shows structural characteristics differing in dimension, number, diameter and orientation of FRC without a preliminary treatment through impregnation of the fibers with fluid resin.
CONCLUSION: An impregnation time of 6 seconds could considerably reduced voids, crazes and microcracks of the fibers, making them more resistant to the other oral and bacterial agents. A larger time of impregnation (6 minutes), with fluid resin before hardening, further enhances the morphological characteristics of the FRC.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26486206

Source DB:  PubMed          Journal:  Minerva Stomatol        ISSN: 0026-4970


  11 in total

Review 1.  Low-Shrinkage Resin Matrices in Restorative Dentistry-Narrative Review.

Authors:  Ebtehal G Albeshir; Rashed Alsahafi; Reem Albluwi; Abdulrahman A Balhaddad; Heba Mitwalli; Thomas W Oates; Gary D Hack; Jirun Sun; Michael D Weir; Hockin H K Xu
Journal:  Materials (Basel)       Date:  2022-04-18       Impact factor: 3.748

2.  Late-Developing Supernumerary Premolars: Analysis of Different Therapeutic Approaches.

Authors:  Sergio Paduano; Roberto Rongo; Alessandra Lucchese; Domenico Aiello; Ambrosina Michelotti; Cristina Grippaudo
Journal:  Case Rep Dent       Date:  2016-09-28

3.  Oxidative Stress Evaluation in Patients Treated with Orthodontic Self-ligating Multibracket Appliances: An in Vivo Case-Control Study.

Authors:  Marco Portelli; Angela Militi; Gabriele Cervino; Floriana Lauritano; Sergio Sambataro; Alberto Mainardi; Riccardo Nucera
Journal:  Open Dent J       Date:  2017-06-30

4.  Comparison between fiber-reinforced polymers and stainless steel orthodontic retainers.

Authors:  Alessandra Lucchese; Maurizio Manuelli; Claudio Ciuffreda; Paolo Albertini; Enrico Gherlone; Letizia Perillo
Journal:  Korean J Orthod       Date:  2018-02-06       Impact factor: 1.372

5.  Clinical Evaluation of Fiber-Reinforced Composite Restorations in Posterior Teeth - Results of 2.5 Year Follow-up.

Authors:  Johanna Tanner; Mimmi Tolvanen; Sufyan Garoushi; Eija Säilynoja
Journal:  Open Dent J       Date:  2018-06-29

Review 6.  Clear Aligners: Between Evolution and Efficiency-A Scoping Review.

Authors:  Alessandra Putrino; Ersilia Barbato; Gabriella Galluccio
Journal:  Int J Environ Res Public Health       Date:  2021-03-11       Impact factor: 3.390

7.  Intramuscular Injections and Dry Needling within Masticatory Muscles in Management of Myofascial Pain. Systematic Review of Clinical Trials.

Authors:  Zuzanna Nowak; Maciej Chęciński; Aleksandra Nitecka-Buchta; Sylwia Bulanda; Danuta Ilczuk-Rypuła; Lidia Postek-Stefańska; Stefan Baron
Journal:  Int J Environ Res Public Health       Date:  2021-09-10       Impact factor: 3.390

8.  Midpalatal Suture Density Evaluation after Rapid and Slow Maxillary Expansion with a Low-Dose CT Protocol: A Retrospective Study.

Authors:  Rosamaria Fastuca; Ambra Michelotti; Riccardo Nucera; Vincenzo D'Antò; Angela Militi; Antonino Logiudice; Alberto Caprioglio; Marco Portelli
Journal:  Medicina (Kaunas)       Date:  2020-03-05       Impact factor: 2.430

9.  Maxillomandibular Transverse Osteodistraction: A Multidisciplinary Case Report with 30-Month Follow-Up.

Authors:  G Turatti; A Bruni; M Savoini; M Giordano; G Gerbino
Journal:  Case Rep Dent       Date:  2020-01-31

10.  Metal versus Fiberglass Post-Orthodontic Retainers Short-Term Effects on Plaque Index and Microbial Colonization: An Observational Study.

Authors:  Stefano Mummolo; Vincenzo Quinzi; Alessandro Nota; Carla Marino; Laura Pittari; Rebecca Jewel Manenti; Simona Tecco
Journal:  Life (Basel)       Date:  2022-02-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.