Literature DB >> 26485509

Comparison of Measurements on Cone Beam Computed Tomography for Periodontal Intrabony Defect with Intra-surgical Measurements.

Fei Li, Ping Yi Jia, Xiang Ying Ouyang.   

Abstract

OBJECTIVE: To explore the relationship between cone beam computed tomography (CBCT) measurements and direct measurements during the surgery to correct intrabony defects.
METHODS: Forty-four patients with 44 intrabony defects who finished initial periodontal therapy and were considered for periodontal surgery were recruited. Digital periapical radiography and CBCT was performed before the surgery. The distance from the bottom of the defect to the cementoenamel junction (CEJ-BD), the depth and mesio-distal width of the defect were measured on CBCT, periapical radiographs and during the surgery. The buccal-lingual width of the defect was only recorded on CBCT and during the surgery. Lastly, intra-surgical linear measurements were compared with measurements of radiographs and CBCT, respectively.
RESULTS: The means of the intra-surgical CEJ to BD, the depth of the defect, the mesio-distal (M-D) width and the buccal-lingual (B-L) width of the defect were 8.90 mm, 5.52 mm, 3.35 mm and 7.40 mm, respectively. Between CBCT measurements and surgical measurements the differences for the CEJ to BD (0.76 ± 1.40 mm) and the depth of the defect (0.63 ± 1.67 mm) were statistically significant, but the differences for the M-D width (-0.17 ± 0.67 mm) and the B-L width (-0.16 ± 0.65 mm) of the defect were not statistically significant.
CONCLUSION: CBCT could provide relatively accurate measurements of the M-D width of the defect and additionally showed accurate measurements of the B-L width of the defect which periapical radiographs could not show. However, for vertical measurements of the intrabony defect (CEJ to BD and depth of the defect), when compared with measurements during the surgery, CBCT showed no advantages over periapical radiographs. A new method should be developed for accurately measuring the periodontal intrabony defects using CBCT in the future.

Entities:  

Mesh:

Year:  2015        PMID: 26485509

Source DB:  PubMed          Journal:  Chin J Dent Res        ISSN: 1462-6446


  3 in total

Review 1.  Precision of cone beam CT to assess periodontal bone defects: a systematic review and meta-analysis.

Authors:  Letícia Fernanda Haas; Glaucia Santos Zimmermann; G De Luca Canto; Carlos Flores-Mir; Márcio Corrêa
Journal:  Dentomaxillofac Radiol       Date:  2017-10-27       Impact factor: 2.419

2.  Evaluation of the clinical efficacy of 1.2% atorvastatin in the treatment of periodontal intraosseous defects by CBCT: A randomized controlled clinical trial.

Authors:  Prerna Y Shirke; Abhay P Kolte; Rajashri A Kolte; Pranjali V Bawanakar
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-10-07

3.  Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study.

Authors:  Chaitanya Adurty; Kanikanti Siva Tejaswi; Cheruvu Ramya Naga Shivani; Didla Navya; Cheni Gopinath; Ravindranath Dhulipalla
Journal:  J Indian Soc Periodontol       Date:  2021-11-01
  3 in total