INTRODUCTION: According to the published literature, blood pressure (BP) measurements performed in the outpatient clinical setting are often inaccurate. The white coat effect and improper technique are the main causes of this imprecision. Construction of a set of readings without them could improve the accuracy of BP measurement.
OBJECTIVE: To evaluate the accuracy and agreement of successive office BP measurements using the awake blood pressure average (ABPa) as the gold standard.
METHODS: BP was measured in 852 patients using three techniques: in office (OBPa); seven successive measurements performed by a nurse using an automatic device; and 24 h of ambulatory BP monitoring. BP averages (BPa) were obtained from the nurse's measurements: 1-2BPa (first and second), 3-7BPa (third to seventh), and 1-7BPa (first to seventh). OBPa and successive measurements were tested against ABPa by calculating the following: average difference in BP of 1-2BPa, 3-7BPa and OBPa, and the area under the curve.
RESULTS: Among the 834 patients eligible, 374 (43.9%) were considered to be hypertensive on the basis of the ABPa (≥135/85 mmHg). 3-7BPa showed the lowest average difference (4/3 mmHg). By contrast, OBPa showed the highest result (21/11 mmHg). The mean difference with 1-2BPa was 8/4 mmHg. The areas under the curve were better with 3-7BPa (0.82-0.85) and 1-2BPa (0.82-0.83) than OBPa (0.67-0.71) for both systolic and diastolic BP.
CONCLUSION: All means from successive measurements showed a better precision than OBPa, even the two first readings. However, more research needs to be carried out before recommendation of the use of this technique in routine practice.

Entities:  

Mesh:

Year:  2016        PMID: 26484743     DOI: 10.1097/MBP.0000000000000161

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  2 in total

1.  Blood pressure measurement protocol determines hypertension phenotypes in a Middle Eastern population.

Authors:  Hazem M Warda; Amany K Elshorbagy; Amira Habib; Ahmed Wagdi; Anastasia S Mihailidou; Mamdouh Warda
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-09-17       Impact factor: 3.738

Review 2.  Ambulatory blood pressure monitoring over 24 h: A Latin American Society of Hypertension position paper-accessibility, clinical use and cost effectiveness of ABPM in Latin America in year 2020.

Authors:  Ramiro A Sánchez; José Boggia; Ernesto Peñaherrera; Weimar Sebba Barroso; Eduardo Barbosa; Raúl Villar; Leonardo Cobos; Rafael Hernández Hernández; Jesús Lopez; José Andrés Octavio; José Z Parra Carrillo; Agustín J Ramírez; Gianfranco Parati
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-02-12       Impact factor: 3.738

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.