Natasha M Gous1, Lesley E Scott, Johan Potgieter, Lumka Ntabeni, Ian Sanne, Wendy S Stevens. 1. *Department of Molecular Medicine and Haematology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa; †National Health Laboratory Service, Johannesburg, South Africa; ‡Department of Haematology, Tshwane Academic Division and University of Pretoria, Pretoria, South Africa; §Right to Care, Johannesburg, South Africa; ‖Clinical HIV Research Unit, Department of Internal Medicine, School of Clinical Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa; and ¶National Priority Program of the National Health Laboratory Service, Johannesburg, South Africa.
Abstract
BACKGROUND: A plethora of point-of-care (POC) tests exist in the HIV and tuberculosis diagnostic pipeline which require rigorous evaluation to ensure performance in the field. The accuracy and feasibility of nurse-operated multidisciplinary-POC testing for HIV antiretroviral therapy (ART) initiation/monitoring was evaluated. METHODS: Random HIV-positive adult patients presenting at 2 treatment clinics in South Africa for ART initiation/monitoring were consented and enrolled. POCT was performed by a dedicated nurse on a venipuncture specimen; Pima (CD4), HemoCue (hemoglobin), Reflotron (alanine aminotransferase, creatinine), Accutrend (lactate) and compared with laboratory testing. External quality assessment, training, workflow, and errors were assessed. RESULTS: n = 324 enrolled at site1; n = 469 enrolled at site 2. Clinical data on n = 305 participants: 65% (n = 198) female with a mean age of 39.8 (21-61) years; mean age of males 43.2 (26-61) years; 70% of patients required 3 or more POC tests/visit. External quality assessment material was suitable for POCT. CD4, hemoglobin and alanine aminotransferase testing showed good agreement with predicate methodology; creatinine and lactate had increased variability. Pima CD4 misclassified up to 11.6% of patients at 500 cells per microliter and reported 4.3%-6% error rate. A dedicated nurse could perform POCT on 7 patients/day; inclusion of Pima CD4 increased time for testing from 6 to 110 minutes. Transcription error rate was 1%. CONCLUSIONS: Nurses can accurately perform multidisciplinary POCT for HIV ART initiation/monitoring. This will however, require a dedicated nurse as current duties will increase if POC is added to workflow. The use of Pima CD4 will increase patients initiated on ART. Connectivity will be central to ensure quality management of results, but overall impact will need to still be addressed.
BACKGROUND: A plethora of point-of-care (POC) tests exist in the HIV and tuberculosis diagnostic pipeline which require rigorous evaluation to ensure performance in the field. The accuracy and feasibility of nurse-operated multidisciplinary-POC testing for HIV antiretroviral therapy (ART) initiation/monitoring was evaluated. METHODS: Random HIV-positive adult patients presenting at 2 treatment clinics in South Africa for ART initiation/monitoring were consented and enrolled. POCT was performed by a dedicated nurse on a venipuncture specimen; Pima (CD4), HemoCue (hemoglobin), Reflotron (alanine aminotransferase, creatinine), Accutrend (lactate) and compared with laboratory testing. External quality assessment, training, workflow, and errors were assessed. RESULTS: n = 324 enrolled at site1; n = 469 enrolled at site 2. Clinical data on n = 305 participants: 65% (n = 198) female with a mean age of 39.8 (21-61) years; mean age of males 43.2 (26-61) years; 70% of patients required 3 or more POC tests/visit. External quality assessment material was suitable for POCT. CD4, hemoglobin and alanine aminotransferase testing showed good agreement with predicate methodology; creatinine and lactate had increased variability. Pima CD4 misclassified up to 11.6% of patients at 500 cells per microliter and reported 4.3%-6% error rate. A dedicated nurse could perform POCT on 7 patients/day; inclusion of Pima CD4 increased time for testing from 6 to 110 minutes. Transcription error rate was 1%. CONCLUSIONS: Nurses can accurately perform multidisciplinary POCT for HIV ART initiation/monitoring. This will however, require a dedicated nurse as current duties will increase if POC is added to workflow. The use of Pima CD4 will increase patients initiated on ART. Connectivity will be central to ensure quality management of results, but overall impact will need to still be addressed.
Authors: Paul K Drain; Jienchi Dorward; Andrew Bender; Lorraine Lillis; Francesco Marinucci; Jilian Sacks; Anna Bershteyn; David S Boyle; Jonathan D Posner; Nigel Garrett Journal: Clin Microbiol Rev Date: 2019-05-15 Impact factor: 26.132
Authors: Michelle M Gill; Lynne M Mofenson; Mamakhetha Phalatse; Vincent Tukei; Laura Guay; Matsepeli Nchephe Journal: PLoS One Date: 2018-02-07 Impact factor: 3.240