Literature DB >> 26483890

Analysis of Trans Fat in Edible Oils with Cooking Process.

Juhee Song1, Joohyeok Park1, Jinyeong Jung1, Chankyu Lee1, Seo Yeoung Gim1, HyeJung Ka1, BoRa Yi1, Mi-Ja Kim2, Cho-Il Kim3, JaeHwan Lee1.   

Abstract

Trans fat is a unsaturated fatty acid with trans configuration and separated double bonds. Analytical methods have been introduced to analyze trans fat content in foods including infrared (IR) spectroscopy, gas chromatography (GC), Fourier transform-infrared (FT-IR) spectroscopy, reverses-phase silver ion high performance liquid chromatography, and silver nitrate thin layer chromatography. Currently, FT-IR spectroscopy and GC are mostly used methods. Trans fat content in 6 vegetable oils were analyzed and processing effects including baking, stir-frying, pan-frying, and frying on the formation of trans fat in corn oil was evaluated by GC. Among tested vegetable oils, corn oil has 0.25 g trans fat/100 g, whereas other oils including rapeseed, soybean, olive, perilla, and sesame oils did not have detectable amount of trans fat content. Among cooking methods, stir-frying increased trans fat in corn oil whereas baking, pan-frying, and frying procedures did not make changes in trans fat content compared to untreated corn oils. However, the trans fat content was so low and food label can be declared as '0' trans based on the regulation of Ministry of Food ad Drug Safety (MFDS) (< 2 g/100 g edible oil).

Entities:  

Keywords:  Fatty acid; Gas chromatography; Processing procedure; Trans fat; Vegetable oil

Year:  2015        PMID: 26483890      PMCID: PMC4609978          DOI: 10.5487/TR.2015.31.3.307

Source DB:  PubMed          Journal:  Toxicol Res        ISSN: 1976-8257


INTRODUCTION

Trans fat is unsaturated fatty acid with trans configuration rather than cis configuration, which is a normal isomer in naturally occurring lipids. However, polyunsaturated fatty acids having double bonds with conjugated forms such as conjugated linoleic acid are not categorized as trans fat due to their health beneficial influence. Hydrogenation, which uses hydrogen gas and metal catalysts to reduce the degree of unsaturation and provide proper physical characteristics in oils since 1890s, is a major process to generate trans fat in our daily diet. Margarine, shortening, and butters are well-known solid fat containing trans isomers. Other sources of trans fat in our daily diet are microorganisms in the rumens of ruminant animals through biohydrogenation. Roseburia hominis A2-183T, Roseburia inulinivorans A2-192T and Ruminococcus obeum-like strain A2-162 can produce trans fatty acids from ruminant sources (1,2). Dairy products including meat, milk, and butter possess about 2~5% of trans fat due to the activities of microorganisms in ruminant animals such as cows and goats (3). The profiles of trans fat from commercially available partially hydrogenated oils and natural resources are not the same. Vaccenic acid (C18:1n11t), which has trans structure in carbon 11 of octadecenoic acid, is major monounsaturated trans fat from biohydrogenation whereas partially hydrogenated oils by chemical hydrogenation have more elaidic acid (C18:1n9t), which has trans part in carbon 9 of octadecenoic acid (1,2). Detrimental health implication of trans fat diet has been filed up for more than four decades. Epidemiologic and biochemical evidence confirmed that excessive trans fats in the diet are a significant risk factor for cardiovascular disease. Health effects of trans fat could be due to the structures of trans fat (1,2). The melting point of stearic acid (C18:0), oleic acid (C18:1n9c), and elaidic acid (C18:1n9t), are 70, −5, and 42℃, respectively, which implies that trans fat exists as solid at room temperature and human body temperature like saturated fat. A number of methods have been introduced to determine total trans fat content including infrared (IR) spectroscopy, gas chromatography (GC), Fourier transform-infrared (FTIR) spectroscopy, reverses-phase silver ion high performance liquid chromatography (HPLC), and silver nitrate thin layer chromatography (AgNO3-TLC) (4). IR region around 967 cm−1 can detect an isolated trans double bond due to the deformation of C-H bonds adjacent to the trans double bond. Official methods of AOCS, AOAC, and IUPAC adapted the measurement of the absorption intensity for total trans content in triacylglycerols, methyl esters of unesterified fatty acids. However, this IR method has some limitations. Triacylglycerols can absorb the region of 970 cm−1 and mono- and di-trans conjugated double bonds absorb at about 950 and 980, and 990 cm−1, respectively, which could interfere with isolated trans fat content. This method can be useful in oils with less than 5% conjugated fatty acids due to the interference of absorption by conjugated bonds and in oils with 5% or higher content of trans fat due to the low intensity of IR absorption (5). The advanced techniques for trans fat analysis in fats and oils are using FT-IR spectroscopy. FT-IR has more advantages including high signal to noise ratio (S/N), high wavelength calibration accuracy (reference He-Ne laser), improved light throughput and speed of analysis (Michelson interferometer), rapid and comprehensive data collection than IR spectroscopy on determining total trans fat. FT-IR technique has better accuracy in oils with less than 5% trans fat through adjustment of baselines for example samples with more than 10% trans fat at 944 and 988 cm−1, less than 10% trans fat at 944 and 985 cm−1, and below 5% trans fat at 944 and 973 cm−1 (6). These FT-IR methods used carbon disulfide like IR method, which may lead to stratification, vapor and air bubbles within cells. A Michelson Interferometer in FT-IR can help all the wavelength of IR pass through samples simultaneously. FT-IR can determine the content of trans fat with high correlation coefficient without using carbon disulfide. trans Peak areas can be integrated from 945 to 990 cm−1 and quantification can be done through fitting the measured trans areas with a second order polynomial (7). Official method of AOCS and AOAC using the FT-IR can be used for quantitative determination of trans fat above 1 and 5%, respectively. Some disadvantages of FT-IR method for determining trans fat are overestimating the content of trans fat, interference from conjugated fatty acids, and the expressing results as equivalent of elaidic acid (C18:1 n9t) content (4). The next advance in trans fat analysis by FT-IR spectroscopy came from using attenuated total reflection-Fourier transform-infrared spectroscopy (ATR-FT-IR). When light strikes two different medium at normal condition, some light partially transmitted and partially reflected. However, in internal reflection mode, light is reflected inside the crystal and evanescent wave is then propagating away from the surface of the crystal like trans fat. The intensity of this wave is partly attenuated by IR and this internal reflection is known as ATR. ATR-FT-IR has been introduced to measure trans fat in oils and fat samples using middle IR range and the ATR cell. This technique requires prior extraction of fat from food samples while further derivatization and use of harmful solvents were not necessary (8). Priego-Capote et al. (9) used ATR-IR spectroscopy for determination of total fat and trans fatty-acids content in bakery products. Da Costa Filho (3) develop a method determining trans fatty acids in edible oils using ATR-FT-IR over a wavelength range of 600-4000 cm−1 and the peak height at 966.3 cm−1 was electronically converted to its negative second derivative for trans fat content. This ATR-FT-IR can determine less than 1% trans fat in edible oils and fats including palm, peanut, soybean, and sunflower oils. GC for the analysis of fatty acid methyl esters (FAME) are the most convenient and accurate method. Therefore, GC methods can isolate trans configuration from cis forms, which can not be achieved by IR or FT-IR spectroscopy methods (10). Conventional GC for analysis of FAME use a slightly polar column using polyglycol Carbowax-20 because natural oils have majorly cis form of double bonds. Separation of trans/cis configuration requires more polar stationary phase including SP-2560, SP-2340, OV-275, BPX-70 or CP-SIL-88 using highly polar cyanosilicone. Recently, the length of capillary columns extended to 100 or 120 m to make better resolution if the isolation of cis/trans isomers (4). American Oil Chemists Society (AOCS) (11) approved official method Ce 1h-05 for the determination of cis, trans-saturated, monounsaturated, and polyunsaturated fatty acids in vegetable or non-ruminant animal oils and fats by capillary GC with a flame ionization detector (FID). Also, Official Method of Analysis 996.06 revised by the AOAC International (AOAC) adapted 100-m high-polarity capillary column as a stationary phase for GC-FID method (10). Different detectors like mass spectrometry (MS) coupled with GC were introduced for trans fat analysis (12). However, overlaps and co-elution of cis/trans isomers observed in chromatograms from GC-FID. In case of foods from ruminant animals like dairy products, different extraction or GC conditions are needed due to a large number of short chained fatty acids and the variety of different molecular structures (13). A combination of GC and IR methods was suggested by Ratnayake et al. (14). Total trans fat measured by IR can be corrected using a formula: IR trans = %18:t + 0.84 x %18:2tt + 1.74 x %18:3t, which can be obtained from GC analysis for trans FAME. The combination of GC and IR methods are useful to determine trans fat content in partially hydrogenated vegetable oil containing more than 5% trans fat. Cruz-Hernandez et al. (15) analyzed conjugated linoleic acids and trans-18:1 isomers in dairy fats by using a combination of GC, silver-ion TLC/GC, and silver-ion liquid chromatography. Reversed-phase HPLC can separate fatty acids based on the apparent carbon number, which is the number of carbons - 2x number of double bonds. This technique cannot separate cis/trans isomers in monounsaturated fatty acids whereas can separate linoleic acid isomers from non-octadecadienoic acids or conjugated linoleic acid. Silver salts can form more stable complex with cis isomers and AgNO3 rather than trans isomer. This properties can be used to differentiate cis/trans isomers and applied to TLC, HPLC, and solid phase extraction columns (4). Analysis of fatty acid profiles in one of typical procedures in food industry because providing information on the content of trans fat should be included in food label. Accurate information on the content of trans fat in foods can come from proper techniques for extracting lipids, saponification, and methylation of fatty acids. Each of above steps may include error sources for the manual operation, parameter settings, and/or data interpretations by the analysts (10). Several official methods have been approved by any official national or international entity. As more accurate and precise methods and technologies are developed, some official methods are not frequently used whereas some are still valid. In Korea, officially approved analysis methods have been suggested in Korea Food Code. All the government agencies and laboratories from food industry should use this official method to certify the content of trans fat in the products. Many reports have conducted on the fatty acid profiles and trans fat content in edible oils. However, effects of conventional cooking procedures including baking, stir-frying, pan-frying, and frying on the formation of trans fat in edible oils are scarce in the literature. Especially, vegetable oils from real cooking conditions for Total Dietary Study (TDS) in Korea have not been tried. The objective of this study was to analyze trans fat content in commonly consumed vegetable oils and to find out effects of conventional cooking treatment on the formation of trans fat.

MATERIALS AND METHODS

Triundecanoin, elaidic acid, mixtures of standard fatty acids, and BF3 were purchased from SigmaAldrich (St. Louis, MO, USA). Other chemicals were purchased from Daejung Chemical Co. (Seoul, Korea). Vegetable oils including corn, rapeseed, soybean, olive, perilla, and sesame oils were obtained from 18 large glossary markets located in 9 different cities in Korea for the purpose of Korean TDS from the year of 2013 to the year of 2016. The selected 9 cities were Seoul, Busan, Incheon, Daegu, Daejeon, Gwangju, Ulsan, Changwon, and Suwon, which had more than 1 million population. Best-selling branded vegetable oils, which were purchased from 18 different sampling sites, were sampled equal amount and blended to make a pool of oil. Each oil sample was provided in triplicate with separated bottles. Vegetable oils and corn oils with cooking procedures were kindly treated by Korea Health Industry Development Institute (KHIDI) based on the procedures of Korea Health and Nutrition Examination Survey conducted from the year of 2008 to the year of 2011. Cooking processes were selected as baking, stir-frying, pan-frying, and frying by KHIDI. Briefly, baking procedure was done using a preheated pan (diameter of 25 cm) at 180℃. Corn oil was spread in a preheated pan with a thin layer and maintained at 180℃ for 1~2 min. Stir-frying procedure for corn oil was done in the preheated pan at 170℃. Corn oil in the pan was stirred continuously by a spatula for 2 min. For pan-frying procedure, corn oil was poured in the preheated pan at 170℃ and was stirred 2 or 3 times per min by the spatula for 2 min. Frying was done using a shallow pan (diameter of 30 cm and height of 20 cm). Corn oil was filled in the shallow pan at the height of 10 cm and heated at 180℃. The corn oil in the shallow pan was further heated for 2 more min at 180℃. Corn oils sample with different cooking procedure were prepared in separated 3 bottles. Triundecanoin (C11:0), an internal standard, was dissolved in n-hexane and added to the extracted oil to the concentration of 1,000 ppm (w/v) and solvent was removed under nitrogen gas flow. Fatty acids were derivatized to fatty acid methyl esters (FAME) using BF3/MeOH (14% boron trifluoride) and analyzed by GC according to AOAC 969.33 (16) with some modification. FAME was analyzed by Hewlett-Packard 6890 gas chromatograph (Agilent Technologies) with a FID, and a SP-2560 column (100 m × 0.25 mm ID, 0.20 µm film) from Supelco (Bellefonte, PA, USA). The oven temperature started at 100℃ for 4 min, increased to 225℃ at 3℃/min, and held at 225℃ for 20 min. The temperatures of injector and detector were 225 and 285℃, respectively. The flow rate of helium carrier gas was 0.75 mL/min, the injection volume was 1 µL, and the split ratio was 1:200. Peaks of GC chromatograms were identified comparing the retention times of a mixture of standard fatty acid methyl esters (SigmaAldrich). Each peak of fatty acid was quantified using an equivalent of the concentration of the internal standard. Samples were separately analyzed in triplicate.

RESULTS AND DISCUSSION

Chromatograms of fatty acid standard mixture (a) and corn oil (b) are shown in Fig. 1. The retention times for internal standard (C11:0), elaidic acid (C18:1n9t), and trans linoleic acid (C18:2n6t) were 25.71, 43.68, and 45.12 min, respectively. Mixtures of standard fatty acids were well separated using current analysis method.
Fig. 1.

Chromatograms of fatty acid standard mixture (A) and of corn oil (B). Arrows indicate the peaks of trans fatty acids.

Fatty acid profiles of 5 edible oils are shown in Table 1. Fatty acid profiles in vegetable oils were different substantially. Corn oil had high linoleic acid (50.28 g/100 g), followed by oleic acid (31.32 g/100 g), palmitic acid (12.65 g/100 g), and stearic acid (2.24 g/100 g). Rapeseed oils had oleic acid (68.20 g/100 g), followed by linoleic acid (15.38 g/100 g), linolenic acid (7.70 g/100 g) and palmitic acid (5.69 g/100 g). Soybean oil had high linoleic acid (45.23 g/100 g), followed by oleic acid (27.03 g/100 g), palmitic acid (16.05 g/100 g), and linolenic acid (6.09 g/100 g). Olive oil had the high oleic acid (78.11 g/100 g) as expected whereas perilla oil had high linolenic acid (57.78 g/100 g).
Table 1.

Major fatty acid profiles and trans fat content in vegetable oils (g/100 g)

SampleFatty acidTrans fatty acid


16:016:118:018:118:218:320:020:120:222:0C18:1n9tC18:2n6t

Corn oil12.65 ± 0.151)0.11 ± 0.002.24 ± 0.0231.32 ± 0.3450.28 ± 0.610.93 ± 0.020.52 ± 0.000.23 ± 0.000.18 ± 0.14N.D.2)N.D.0.25 ± 0.01
Rapeseed oil5.69 ± 0.13N.D.2.28 ± 0.0168.20 ± 0.2415.38 ± 0.127.70 ± 0.08N.D.0.75 ± 0.08N.D.N.D.N.D.N.D.
Soybean oil16.05 ± 0.02N.D.5.59 ± 0.0427.03 ± 0.0145.23 ± 0.086.09 ± 0.02N.D.N.D.N.D.N.D.N.D.N.D.
Olive oil13.65 ± 0.010.75 ± 0.003.38 ± 0.0278.11 ± 0.053.61 ± 0.020.49 ± 0.02N.D.N.D.N.D.N.D.N.D.N.D.
Perilla seed oil6.87 ± 0.080.22 ± 0.002.13 ± 0.0219.71 ± 0.1510.71 ± 0.1457.78 ± 0.270.16 ± 0.000.12 ± 0.00N.D.N.D.N.D.N.D.
Sesame oil10.58 ± 0.60N.D.6.18 ± 0.3941.41 ± 2.9433.83 ± 1.73N.D.0.64 ± 0.03N.D.N.D.0.08 ± 0.14N.D.N.D.

1)Mean ± standard deviation (n = 3).

2)Not detected.

1)Mean ± standard deviation (n = 3). 2)Not detected. Corn oil had 0.25 g C18:2n6t/100 g whereas other oils including rapeseed, soybean, olive, perilla, and sesame oils did not possess trans fat. Presence of trans fat in corn oil can be found in other previous reports. Zhang et al. (17) analyzed C18 trans fatty acids in edible oils including corn, sunflower, and olive oils using GC-mass spectrometry and found out that 1.29 g trans fat/100 g FAME in corn oil. C18:2 and C18:3 trans fat were almost equally responsible for the trans fat in corn oil (17). Trans fat in 19 corn oil in China was all detected ranging from 0.56 to 4.75 g/100 g with average of 2.01 g/100 g (18). Mossoba et al. (19) analyzed fatty acid profiles in edible oils including canola, coconut, corn, flax, grapeseed, olive, peanut, safflower, shortening, sunflower, and walnut oils using FT-NIR and GC methods and found out 0.36 to 0.99% trans fat in corn oil by GC method and 1.2 to 1.4% trans fat in corn oil by FT-NIR method. A value of 0 g trans fat per serving can be labeled if trans fat content is below 0.5 g per serving in US. Average serving size of oils in US is 14 g, which corresponds to a trans fat content of < 3.6% in the US. The detected 0.25% trans fat in corn oil is less than limitation and can be declared as 0 trans fat in food label. Effects of cooking methods on the changes of trans fat content in corn oils are shown in Table 2. Processing including baking, stir-frying, pan-frying, and frying used thermal energy and lipid oxidation occurred in corn oils. Among cooking methods, stir-frying produced higher trans fat in corn oil than new corn oils whereas baking, pan-frying, and frying procedures did not make changes among trans fat content in corn oils. High temperature treatment can cause the formation of trans fat in oils through oxidation process. Żyżelewicz et al. (20) reported the formation of elaidic trans fat (C18:1n9t) in cocoa buffer extracted from roasted beans when roasting temperature was 135℃ and roasting duration was 15 min. Tsuzuki et al. (21) confirmed the significant increases in trans fatty acids in edible oils during frying and heating process. When sliced raw potatoes were fried at 180℃, frying oils from potato frying had higher trans fatty acid than oils with the same temperature heating without potato frying (21).
Table 2.

Effects of cooking process on trans fat content in corn oil (g/100 g)

Processing methodTrans fatty acid

C18:1n9tC18:2n6t

RawN.D.1)0.25 ± 0.012)
BakingN.D0.26 ± 0.01
Stir-frying0.48 ± 0.320.56 ± 0.16
Pan-fryingN.D0.27 ± 0.01
FryingN.D0.26 ± 0.01

1)Not detected.

2)Mean ± standard deviation (n = 3).

1)Not detected. 2)Mean ± standard deviation (n = 3). Trans formation from cis configuration in unsaturated lipids is inevitable steps during autoxidation, which is one of basic lipid oxidation mechanisms. Autoxidation is known as a free radical chain reaction with initiation, propagation, and final steps. Initial step is a formation of lipid radicals (L•) by losing hydrogen atom from unsaturated lipid (LH). Double bonds in cis configuration are unstable and tend to form trans configuration, which is more stable form than cis form (22). The higher temperature accelerates the reaction rates of oxidation and the more trans fat is generated. Among tested cooking methods, stir-frying procedure at 170℃ heating and continuous stirring process may accelerate the rates of lipid oxidation and formation of trans fat compared to other cooking procedures. However, the content of trans fat in vegetable oil after stir-frying process was far below the trans fat level compared to other food products like margarine made of partially hydrogenated oils (23). The content of trans fat in edible oils was so low and food label can be declared as ‘0’ trans fat based on the regulation of Ministry of Food ad Drug Safety (MFDS). In case of edible oils, trans fat content below 2 g per 100 g oil can be declared as ‘0’ trans. In conclusion, GC-FID is a reliable and accurate technique for the analysis of trans fat in vegetable oils. Among conventional cooking methods, stir-frying step can increase trans fat content in edible oils due to the high temperature treatment and continuous stirring, which might accelerate the rates of lipid oxidation. This GC-FID technique can be applied to any food matrix with proper lipid extraction methods for the quantification of trans fat content.
  5 in total

Review 1.  Trans fats in America: a review of their use, consumption, health implications, and regulation.

Authors:  Valentina Remig; Barry Franklin; Simeon Margolis; Georgia Kostas; Theresa Nece; James C Street
Journal:  J Am Diet Assoc       Date:  2010-04

Review 2.  The toxicity of dietary trans fats.

Authors:  Riya Ganguly; Grant N Pierce
Journal:  Food Chem Toxicol       Date:  2015-02-12       Impact factor: 6.023

Review 3.  Evaluation of gas chromatographic methods for the determination of trans fat.

Authors:  Pierluigi Delmonte; Jeanne I Rader
Journal:  Anal Bioanal Chem       Date:  2007-06-16       Impact factor: 4.142

4.  Developing a rapid and sensitive method for determination of trans-fatty acids in edible oils using middle-infrared spectroscopy.

Authors:  Paulo Augusto da Costa Filho
Journal:  Food Chem       Date:  2014-02-28       Impact factor: 7.514

5.  Methods for analysis of conjugated linoleic acids and trans-18:1 isomers in dairy fats by using a combination of gas chromatography, silver-ion thin-layer chromatography/gas chromatography, and silver-ion liquid chromatography.

Authors:  Cristina Cruz-Hernandez; Zeyuan Deng; Jianqiang Zhou; Arthur R Hill; Martin P Yurawecz; Pierluigi Delmonte; Magdi M Mossoba; Michael E R Dugan; John K G Kramer
Journal:  J AOAC Int       Date:  2004 Mar-Apr       Impact factor: 1.913

  5 in total
  5 in total

Review 1.  Time Domain (TD) Proton NMR Analysis of the Oxidative Safety and Quality of Lipid-Rich Foods.

Authors:  Tatiana Osheter; Charles Linder; Zeev Wiesman
Journal:  Biosensors (Basel)       Date:  2022-04-09

2.  Olive oil from the 79 A.D. Vesuvius eruption stored at the Naples National Archaeological Museum (Italy).

Authors:  Raffaele Sacchi; Adele Cutignano; Gianluca Picariello; Antonello Paduano; Alessandro Genovese; Francesco Siano; Genoveffa Nuzzo; Simonetta Caira; Carmine Lubritto; Paola Ricci; Alessia D'Auria; Gaetano Di Pasquale; Andrea Motta; Francesco Addeo
Journal:  NPJ Sci Food       Date:  2020-11-02

Review 3.  Influence of Heating during Cooking on Trans Fatty Acid Content of Edible Oils: A Systematic Review and Meta-Analysis.

Authors:  Saiuj Bhat; Damian Maganja; Liping Huang; Jason H Y Wu; Matti Marklund
Journal:  Nutrients       Date:  2022-04-02       Impact factor: 5.717

4.  Effects of Repeated Heating on Fatty Acid Composition of Plant-Based Cooking Oils.

Authors:  Zoltan Szabo; Tamas Marosvölgyi; Eva Szabo; Viktor Koczka; Zsofia Verzar; Maria Figler; Tamas Decsi
Journal:  Foods       Date:  2022-01-12

Review 5.  Oxidative Stability of Vegetal Oil-Based Lubricants.

Authors:  Clarissa Murru; Rosana Badía-Laíño; Marta E Díaz-García
Journal:  ACS Sustain Chem Eng       Date:  2021-01-19       Impact factor: 8.198

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.