Literature DB >> 26481643

The Glucose Measurement Industry and Hemoglobin A1c: An Opportunity for Creative Destruction.

George Cembrowski1.   

Abstract

The MyStar Extra self-monitoring blood glucose (SMBG) system provides moving estimates of the patient's hemoglobin A1c (HbA1c). There is a treasure trove of highly accurate glucose data available from highly accurate SMBG, CGM and FGM along with highly accurate HPLC HbA1c. If Nathan's criteria are used to select subjects whose glucoses can be correlated to the HbA1c, then algorithms can be developed for robustly transforming glucose into HbA1c. These algorithms can then be implemented in any SMBG or with the CGM and FGM software. This calculated HbA1c would even be accurate with Nathan's excluded population thus reducing the use of fructosamine and glycated protein. Finally, the developer of these new algorithms is advised to use a specific approach for testing her algorithm.
© 2015 Diabetes Technology Society.

Entities:  

Keywords:  anemia; calculated HbA1c; glucose; hemoglobin A1c

Mesh:

Substances:

Year:  2015        PMID: 26481643      PMCID: PMC4738224          DOI: 10.1177/1932296815610779

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  20 in total

1.  Evidence for independent heritability of the glycation gap (glycosylation gap) fraction of HbA1c in nondiabetic twins.

Authors:  Robert M Cohen; Harold Snieder; Christopher J Lindsell; Huriya Beyan; Mohammed I Hawa; Stuart Blinko; Raymond Edwards; Timothy D Spector; R David G Leslie
Journal:  Diabetes Care       Date:  2006-08       Impact factor: 19.112

Review 2.  Iron deficiency anemia.

Authors:  Shersten Killip; John M Bennett; Mara D Chambers
Journal:  Am Fam Physician       Date:  2007-03-01       Impact factor: 3.292

3.  HbA(1c) levels are genetically determined even in type 1 diabetes: evidence from healthy and diabetic twins.

Authors:  H Snieder; P A Sawtell; L Ross; J Walker; T D Spector; R D Leslie
Journal:  Diabetes       Date:  2001-12       Impact factor: 9.461

Review 4.  Pitfalls in hemoglobin A1c measurement: when results may be misleading.

Authors:  Michael S Radin
Journal:  J Gen Intern Med       Date:  2013-09-04       Impact factor: 5.128

5.  Accuracy and robustness of dynamical tracking of average glycemia (A1c) to provide real-time estimation of hemoglobin A1c using routine self-monitored blood glucose data.

Authors:  Boris P Kovatchev; Frank Flacke; Jochen Sieber; Marc D Breton
Journal:  Diabetes Technol Ther       Date:  2013-12-03       Impact factor: 6.118

6.  Hemoglobin A1c, fasting plasma glucose, and 2-hour plasma glucose distributions in U.S. population subgroups: NHANES 2005-2010.

Authors:  Andy Menke; Keith F Rust; Peter J Savage; Catherine C Cowie
Journal:  Ann Epidemiol       Date:  2013-10-18       Impact factor: 3.797

7.  Association of glycation gap with mortality and vascular complications in diabetes.

Authors:  Ananth U Nayak; Alan M Nevill; Paul Bassett; Baldev M Singh
Journal:  Diabetes Care       Date:  2013-07-08       Impact factor: 19.112

8.  Diabetes performance measures: current status and future directions.

Authors:  Patrick J O'Connor; Noni L Bodkin; Judith Fradkin; Russell E Glasgow; Sheldon Greenfield; Edward Gregg; Eve A Kerr; L Gregory Pawlson; Joseph V Selby; John E Sutherland; Michael L Taylor; Carol H Wysham
Journal:  Diabetes Care       Date:  2011-07       Impact factor: 19.112

Review 9.  A1C versus glucose testing: a comparison.

Authors:  David B Sacks
Journal:  Diabetes Care       Date:  2011-02       Impact factor: 19.112

10.  Translating the A1C assay into estimated average glucose values.

Authors:  David M Nathan; Judith Kuenen; Rikke Borg; Hui Zheng; David Schoenfeld; Robert J Heine
Journal:  Diabetes Care       Date:  2008-06-07       Impact factor: 19.112

View more
  1 in total

1.  A Social Marketing Intervention to Improve Treatment Adherence in Patients with Type 1 Diabetes.

Authors:  Citlali Calderon; Lorena Carrete; Jorge Vera-Martínez; María Esther Gloria-Quintero; María Del Socorro Romero-Figueroa
Journal:  Int J Environ Res Public Health       Date:  2021-03-31       Impact factor: 3.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.