Literature DB >> 26481275

Modelling characteristics to predict Legionella contamination risk - Surveillance of drinking water plumbing systems and identification of risk areas.

Sebastian Völker1, Christiane Schreiber2, Thomas Kistemann3.   

Abstract

For the surveillance of drinking water plumbing systems (DWPS) and the identification of risk factors, there is a need for an early estimation of the risk of Legionella contamination within a building, using efficient and assessable parameters to estimate hazards and to prioritize risks. The precision, accuracy and effectiveness of ways of estimating the risk of higher Legionella numbers (temperature, stagnation, pipe materials, etc.) have only rarely been empirically assessed in practice, although there is a broad consensus about the impact of these risk factors. We collected n = 807 drinking water samples from 9 buildings which had had Legionella spp. occurrences of >100 CFU/100mL within the last 12 months, and tested for Legionella spp., L. pneumophila, HPC 20°C and 36°C (culture-based). Each building was sampled for 6 months under standard operating conditions in the DWPS. We discovered high variability (up to 4 log(10) steps) in the presence of Legionella spp. (CFU/100 mL) within all buildings over a half year period as well as over the course of a day. Occurrences were significantly correlated with temperature, pipe length measures, and stagnation. Logistic regression modelling revealed three parameters (temperature after flushing until no significant changes in temperatures can be obtained, stagnation (low withdrawal, qualitatively assessed), pipe length proportion) to be the best predictors of Legionella contamination (>100 CFU/100 mL) at single outlets (precision = 66.7%; accuracy = 72.1%; F(0.5) score = 0.59).
Copyright © 2015 Elsevier GmbH. All rights reserved.

Entities:  

Keywords:  Contamination risk prediction; Drinking water plumbing systems; Germany; Legionella; Risk assessment

Mesh:

Substances:

Year:  2015        PMID: 26481275     DOI: 10.1016/j.ijheh.2015.09.007

Source DB:  PubMed          Journal:  Int J Hyg Environ Health        ISSN: 1438-4639            Impact factor:   5.840


  6 in total

1.  High Prevalence and Genetic Polymorphisms of Legionella in Natural and Man-Made Aquatic Environments in Wenzhou, China.

Authors:  Leyi Zhang; Yi Li; Xin Wang; Zhihui Shangguan; Haijian Zhou; Yuejin Wu; Lianghuai Wang; Hongyu Ren; Yun Hu; Meifen Lin; Tian Qin
Journal:  Int J Environ Res Public Health       Date:  2017-02-24       Impact factor: 3.390

Review 2.  From Copper Tolerance to Resistance in Pseudomonas aeruginosa towards Patho-Adaptation and Hospital Success.

Authors:  Maxine Virieux-Petit; Florence Hammer-Dedet; Fabien Aujoulat; Estelle Jumas-Bilak; Sara Romano-Bertrand
Journal:  Genes (Basel)       Date:  2022-02-04       Impact factor: 4.096

Review 3.  Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands.

Authors:  Ana Pereira; Ana Rosa Silva; Luis F Melo
Journal:  Microorganisms       Date:  2021-06-03

4.  Photocatalytic biocidal effect of copper doped TiO2 nanotube coated surfaces under laminar flow, illuminated with UVA light on Legionella pneumophila.

Authors:  Martina Oder; Tilen Koklič; Polona Umek; Rok Podlipec; Janez Štrancar; Martin Dobeic
Journal:  PLoS One       Date:  2020-01-15       Impact factor: 3.240

5.  Rapid Testing and Interventions to Control Legionella Proliferation following a Legionnaires' Disease Outbreak Associated with Cooling Towers.

Authors:  Charlotte Young; Duncan Smith; Tim Wafer; Brian Crook
Journal:  Microorganisms       Date:  2021-03-17

6.  Variable Legionella Response to Building Occupancy Patterns and Precautionary Flushing.

Authors:  William J Rhoads; Meril Sindelar; Céline Margot; Nadine Graf; Frederik Hammes
Journal:  Microorganisms       Date:  2022-03-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.