A conservative approach to retrieve a fractured abutment screw - Case report.

Thiago de Almeida Prado Naves Carneiro1, Marcel Santana Prudente2, Roberto Sales E Pessoa3, Gustavo Mendonça4, Flávio Domingues das Neves2.   

Abstract

INTRODUCTION: Regarding implant-supported prostheses, the most reported types of complications are related to loosening or fracturing of abutment or prosthesis screws. This case report shows a series of procedures that allowed a conservative solution for a fractured screw. It avoided removing the implant and also allowed the same prosthesis to be used after guided-drilling the fractured screw and re-tapping the implant internal threads. The same prosthesis was replaced immediately after the procedure. PATIENT: A 67-year-old male patient, who had a fractured abutment screw of the lower left first molar implant. The patient decided for the conservative treatment option and an attempt was made to remove the fractured screw. DISCUSSION: Parafunctional habits can generate excessive occlusal forces, which are risk factors associated with loosening and fracturing implant screws and even the fixtures themselves. This case report focus on the probable causes, difficulties and risks associated with this procedure and it also discusses the alternative approaches.
CONCLUSION: The purposed treatment allowed a time and money saving resolution for fractured abutment screws.
Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Implant re-tapping; Osseointegrated implant; Screw fracture

Mesh:

Year:  2015        PMID: 26481059     DOI: 10.1016/j.jpor.2015.09.003

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  3 in total

Review 1.  Management of perishing implants with abutment screw fracture - A systematic review.

Authors:  Soja Raju; Vivek V Nair; Harsha Kumar Karunakaran; Noxy George Manjuran
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

2.  Restoration: Implant with Devastated Platform through Metal Post.

Authors:  Luna Salinas Tatiana; Del Valle Lovato Juan
Journal:  Case Rep Dent       Date:  2017-02-13

3.  Implant-Abutment Misfit after Cyclic Loading: An In Vitro Experimental Study.

Authors:  John Eversong Lucena de Vasconcelos; Jefferson David Melo de Matos; Daher Antonio Queiroz; Guilherme da Rocha Scalzer Lopes; Bruna Caroline Gonçalves Vasconcelos de Lacerda; Marco Antonio Bottino; Cecilia Pedroso Turssi; Roberta Tarkany Basting; Flávia Lucisano Botelho do Amaral; Fabiana Mantovani Gomes França
Journal:  Materials (Basel)       Date:  2022-08-03       Impact factor: 3.748

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.