Soft tissue and crestal bone changes around implants with platform-switched abutments placed nonsubmerged at subcrestal position: a 2-year clinical and radiographic evaluation.

Mario Aimetti, Francesco Ferrarotti, Giulia Maria Mariani, Carlo Ghelardoni, Federica Romano.   

Abstract

PURPOSE: To evaluate crestal bone changes around implants with platform-switched abutments placed 1 mm subcrestally in a prospective clinical investigation.
MATERIALS AND METHODS: Forty consecutive systemically healthy patients (mean age ± standard deviation [SD], 55.2 ± 8.7 years) with one or more missing teeth were consecutively treated with 1-mm subcrestally positioned, platform-switched, tapered, full treated implants restored with coded abutments. A total of 58 implants were placed. Final restorations were delivered 4 to 8 months after implant insertion. Digital standardized periapical radiographs using customized film holders were obtained at the time of implant insertion, and at 12 and 24 months after final prosthesis placement. Marginal peri-implant bone levels were measured at the mesial and distal surfaces of each implant using digital image software.
RESULTS: All implants osseointegrated and were clinically stable at the 2-year follow-up. The cumulative survival rate was 100%. From implant insertion to the 2-year follow-up, the mean bone loss was 0.32 ± 0.37 mm. No significant differences related to sex, implant site, and bone density were observed. The mean midbuccal and interproximal soft tissue margin positions were 1.13 ± 0.5 mm and 1.15 ± 0.6 mm coronal to the prosthetic finish line, respectively.
CONCLUSION: There is limited clinical information regarding the amount of marginal bone loss around two-piece platform-switched implants placed at subcrestal positions. Results of this study suggest that platform switching and subcrestal location of the implant-abutment interface may be effective in reducing bone loss and in preserving esthetics around dental implants.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26478966     DOI: 10.11607/jomi.4017

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Comparison of digital protocols for the measurement of peri-implant marginal bone loss.

Authors:  David Peñarrocha-Oltra; Ivan Palau; Guillermo Cabanes; Beatriz Tarazona; Maria Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2018-12-01

2.  Impact of crestal and subcrestal implant placement upon changes in marginal peri-implant bone level. A systematic review.

Authors:  H Pellicer-Chover; M Díaz-Sanchez; D Soto-Peñaloza; M-A Peñarrocha-Diago; L Canullo; D Peñarrocha-Oltra
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

Review 3.  Influence of marginal bone loss on peri-implantitis: Systematic review of literature.

Authors:  Alba Carrasco-García; Lizett Castellanos-Cosano; José-Ramon Corcuera-Flores; Antonio Rodríguez-Pérez; Daniel Torres-Lagares; Guillermo Machuca-Portillo
Journal:  J Clin Exp Dent       Date:  2019-11-01

4.  Prosthodontics Using Removable Platform Switching Technologies (Multiunit, On1) as Exemplified by Conical Connection Implant Systems for Early and Immediate Loading.

Authors:  Roman Studenikin
Journal:  Int J Dent       Date:  2021-04-19

5.  Influence of Bone-Level Dental Implants Placement and of Cortical Thickness on Osseointegration: In Silico and In Vivo Analyses.

Authors:  Javier Gil; Clara Sandino; Miguel Cerrolaza; Román Pérez; Mariano Herrero-Climent; Blanca Rios-Carrasco; Jose Vicente Rios-Santos; Aritza Brizuela
Journal:  J Clin Med       Date:  2022-02-16       Impact factor: 4.241

6.  Peri-Implant Marginal Bone Changes around Dental Implants with Platform-Switched and Platform-Matched Abutments: A Retrospective 5-Year Radiographic Evaluation.

Authors:  Hsi-Kuei Lin; Jerry Chin-Yi Lin; Yu-Hwa Pan; Eisner Salamanca; Yi-Ting Chang; Yung-Szu Hsu; Yi-Fan Wu; Chin-Kai Lin; Odontuya Dorj; Wei-Jen Chang
Journal:  J Pers Med       Date:  2022-07-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.