Literature DB >> 26477363

Current use and perspective of indocyanine green clearance in liver diseases.

Eric Levesque1, Eléonore Martin2, Daniela Dudau2, Chetana Lim3, Gilles Dhonneur2, Daniel Azoulay3.   

Abstract

Indocyanine green (ICG) is a water-soluble anionic compound that binds to plasma proteins after intravenous administration. It is selectively taken up at the first pass by hepatocytes and excreted unchanged into the bile. With the development of ICG elimination measurement by spectrophotometry, the ICG retention test has become a safe, rapid, reproducible, inexpensive and noninvasive tool for the assessment of liver function. Clinical evidence suggests that the ICG retention test can enable the establishment of tailored management strategies by providing prognostic information. In particular, this method has been evaluated as a prognostic marker in patients with advanced cirrhosis or awaiting liver transplantation. In addition, it is used as a marker of portal hypertension in cirrhotic patients, as a prognostic factor in intensive care units and for the assessment of liver function in patients undergoing liver surgery. Since recent technology enables ICG-PDR to be measured noninvasively at the bedside, this parameter is an attractive addition to liver function and regional haemodynamic monitoring. However, the current state-of-the-art as concerns this technology remains at a low level of evidence and thorough assessment is required.
Copyright © 2015 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Indocyanine green clearance; Liver; Liver function

Mesh:

Substances:

Year:  2015        PMID: 26477363     DOI: 10.1016/j.accpm.2015.06.006

Source DB:  PubMed          Journal:  Anaesth Crit Care Pain Med        ISSN: 2352-5568            Impact factor:   4.132


  23 in total

1.  Indocyanine green dye clearance test: early graft (dys)-function and long-term mortality after liver transplant. Should we continue to use it? An observational study.

Authors:  Vittorio Cherchi; Luigi Vetrugno; Victor Zanini; Thomas Isler; Riccardo Pravisani; Alice Borghi; Umberto Baccarani; Giovanni Terrosu; Andrea Risaliti; Tiziana Bove
Journal:  J Clin Monit Comput       Date:  2020-03-12       Impact factor: 2.502

2.  Quantification of fluorescence angiography in a porcine model.

Authors:  Nikolaj Nerup; Helene Schou Andersen; Rikard Ambrus; Rune Broni Strandby; Morten Bo Søndergaard Svendsen; Mads Holst Madsen; Lars Bo Svendsen; Michael Patrick Achiam
Journal:  Langenbecks Arch Surg       Date:  2016-11-15       Impact factor: 3.445

Review 3.  Indocyanine green kinetics to assess liver function: Ready for a clinical dynamic assessment in major liver surgery?

Authors:  Andrea De Gasperi; Ernestina Mazza; Manlio Prosperi
Journal:  World J Hepatol       Date:  2016-03-08

4.  Non-invasive Evaluation of NAFLD with Indocyanine Green Clearance Test: a Preliminary Study in Morbidly Obese Patients Undergoing Bariatric Surgery.

Authors:  Pierre Eric Danin; Rodolphe Anty; Stephanie Patouraux; Marc Raucoules-Aimé; Jean Gugenheim; Albert Tran; Philippe Gual; Antonio Iannelli
Journal:  Obes Surg       Date:  2018-03       Impact factor: 4.129

5.  In vivo visualization and ex vivo quantification of experimental myocardial infarction by indocyanine green fluorescence imaging.

Authors:  Dmitry Sonin; Garry Papayan; Evgeniia Pochkaeva; Svetlana Chefu; Sarkis Minasian; Dmitry Kurapeev; Jarle Vaage; Nickolay Petrishchev; Michael Galagudza
Journal:  Biomed Opt Express       Date:  2016-12-08       Impact factor: 3.732

6.  Photoacoustic-Guided Surgery with Indocyanine Green-Coated Superparamagnetic Iron Oxide Nanoparticle Clusters.

Authors:  Jayesh P Thawani; Ahmad Amirshaghaghi; Lesan Yan; Joel M Stein; Jessica Liu; Andrew Tsourkas
Journal:  Small       Date:  2017-07-27       Impact factor: 13.281

7.  Association between the donor to recipient ICG-PDR variation rate and the functional recovery of the graft after orthotopic liver transplantation: A case series.

Authors:  Vittorio Cherchi; Luigi Vetrugno; Giovanni Terrosu; Victor Zanini; Marco Ventin; Riccardo Pravisani; Francesco Tumminelli; Pier Paolo Brollo; Erica Boscolo; Roberto Peressutti; Dario Lorenzin; Tiziana Bove; Andrea Risaliti; Umberto Baccarani
Journal:  PLoS One       Date:  2021-08-27       Impact factor: 3.240

8.  Using Indocyanine Green Extraction to Predict Liver Function After Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma.

Authors:  Krithika Suresh; Dawn Owen; Latifa Bazzi; William Jackson; Randall K Ten Haken; Kyle Cuneo; Mary Feng; Theodore S Lawrence; Matthew J Schipper
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-09-22       Impact factor: 7.038

9.  Comparison between preoperative two-dimensional shear wave elastography and indocyanine green clearance test for prediction of post-hepatectomy liver failure.

Authors:  Tingting Qiu; Rong Fu; Wenwu Ling; Jiawu Li; Jiulin Song; Zhenru Wu; Yujun Shi; Yuqing Zhou; Yan Luo
Journal:  Quant Imaging Med Surg       Date:  2021-05

10.  Prognostic Impact of Indocyanine Green Plasma Disappearance Rate in Hepatocellular Carcinoma Patients after Radiofrequency Ablation: A Prognostic Nomogram Study.

Authors:  Motoi Azumi; Takeshi Suda; Shuji Terai; Kouhei Akazawa
Journal:  Intern Med       Date:  2017-05-01       Impact factor: 1.271

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.