Literature DB >> 26475165

The impact of blood pressure cuff location on the accuracy of noninvasive blood pressure measurements in obese patients: an observational study.

Nicholas Anast1, Megan Olejniczak2, Jerry Ingrande1, John Brock-Utne3,4.   

Abstract

PURPOSE: Obesity presents many challenges to the anesthesiologist, including poorly fitting blood pressure (BP) cuffs due to the conical shape of the upper arm. The aim of this study was to determine the accuracy of noninvasive BP readings, obtained from a noninvasive BP cuff using various cuff locations and wrapping techniques, compared with invasive intra-arterial BP readings.
METHODS: Thirty American Society of Anesthesiologists physical status I-III obese (body mass index > 30 kg·m(-2)) individuals undergoing non-cardiac surgery were enrolled in this observational study. Serial oscillometric noninvasive BP (NIBP) measurements were taken in the patients' forearm and upper arm with two different wrapping formations (one following the contour of the upper arm, the other keeping cuff edges parallel). These NIBP measurements were compared with invasive arterial blood pressure (ABP) measurements taken from the ipsilateral radial artery. The precision and bias of the NIBP and ABP measurements were determined using Bland-Altman analysis. Analysis of variance and Welch's t test were used to determine between-group differences in bias.
RESULTS: There was poor agreement between the ABP measurements and all types of NIBP measurements. Each of our study participants had a least one NIBP parameter (mean arterial pressure, systolic BP, or diastolic BP) that was > 10 mmHg different than the corresponding ABP parameter. Upper arm BP measurements showed a statistically insignificant trend toward underestimating ABP. For all cuff positions and wrapping techniques, systolic BP offered the best agreement between NIBP and ABP measurements.
CONCLUSIONS: All the forms of NIBP cuff orientation studied had unacceptable precision and bias compared with invasive ABP measurements. When patient and/or surgical conditions necessitate accurate BP monitoring, direct arterial measurement should be considered over NIBP measurements in obese patients.

Entities:  

Mesh:

Year:  2015        PMID: 26475165     DOI: 10.1007/s12630-015-0509-6

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  7 in total

Review 1.  Techniques for Non-Invasive Monitoring of Arterial Blood Pressure.

Authors:  Agnes S Meidert; Bernd Saugel
Journal:  Front Med (Lausanne)       Date:  2018-01-08

2.  Validation of two automatic devices, Omron HEM-6232T and HEM-6181, for self-measurement of blood pressure at the wrist according to the ANSI/AAMI/ISO 81060-2:2013 protocol and the European Society of Hypertension International Protocol revision 2010.

Authors:  Kanako Saito; Yukiko Hishiki; Hakuo Takahashi
Journal:  Vasc Health Risk Manag       Date:  2019-03-06

3.  Comparison of oscillometric, non-invasive and invasive arterial pressure monitoring in patients undergoing laparoscopic bariatric surgery - a secondary analysis of a prospective observational study.

Authors:  Ulf Lorenzen; Gunnar Elke; Jonathan Hansen; Markus Pohlmann; Jan H Beckmann; Phil Klose; Matthias Gruenewald; Jochen Renner
Journal:  BMC Anesthesiol       Date:  2022-03-28       Impact factor: 2.217

Review 4.  Blood pressure monitoring techniques in the natural state of multi-scenes: A review.

Authors:  Ziyi Liu; Congcong Zhou; Hongwei Wang; Yong He
Journal:  Front Med (Lausanne)       Date:  2022-08-26

Review 5.  Recent Advances in Non-Invasive Blood Pressure Monitoring and Prediction Using a Machine Learning Approach.

Authors:  Siti Nor Ashikin Ismail; Nazrul Anuar Nayan; Rosmina Jaafar; Zazilah May
Journal:  Sensors (Basel)       Date:  2022-08-18       Impact factor: 3.847

Review 6.  Intraoperative Monitoring of the Obese Patient Undergoing Surgery: A Narrative Review.

Authors:  Andrea P Haren; Shrijit Nair; Maria C Pace; Pasquale Sansone
Journal:  Adv Ther       Date:  2021-06-05       Impact factor: 3.845

7.  Factors influencing home blood pressure monitor ownership in a large clinical trial.

Authors:  Thineskrishna Anbarasan; Amy Rogers; David A Rorie; J W Kerr Grieve; Robert W V Flynn; Thomas M MacDonald; Isla S Mackenzie
Journal:  J Hum Hypertens       Date:  2021-03-02       Impact factor: 3.012