The use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera® scleral contact lens fitting process.

Sarah La Porta Weber1, Renato Ambrósio2, César Lipener3, Cleusa Coral-Ghanem4, Ana Luisa Hofling-Lima3.   

Abstract

PURPOSE: To test for associations between Pentacam(®) derived topography variables and to evaluate the predictive power of those variables in relation to scleral contact lens (SCL) fit.
SETTING: Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, São Paulo-SP, Brazil.
DESIGN: Prospective observational non-randomised, non-comparative study.
METHODS: Forty-seven patients (63 eyes) were indicated for the use of Esclera(®) SCL. All patients underwent Scheimpflug imaging before the initial SCL evaluation. The following parameters were measured by Pentacam: corneal elevations, thickness, density, and anterior chamber depth (ACD). Correlations between the SCL parameters and the Pentacam measurements were analysed with Pearson's correlation coefficients. A simple linear regression model was created for each lens parameter using the most-correlated Pentacam variable.
RESULTS: In the total group, the results show correlations between the SCL parameters and the corneal astigmatism, ACD and pentacam-measured corneal height (Hm), with p<0.001 each. In addition, an inverse correlation between the lens sagittal depth (LSD) and the anterior radii minimum was shown (p<0.001). In the keratoconus group, the results show correlations between the SCL parameters and ACD and Hm (p<0.001, each). An inverse correlation between the LSD and the total thickness corneal density average was also observed (p=0.003).
CONCLUSION: There was a positive correlation between the LSD and ACD, even as LD and ACD in the keratoconus group. Thus, these results suggest that certain Pentacam measurements can be good predictors of the most appropriate Esclera lens to be fitted in keratoconus patients.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Contact lens; Dry eye; Keratoconus; Scheimpflug camera; Scleral lens fitting; Scleral lenses

Mesh:

Year:  2015        PMID: 26474924     DOI: 10.1016/j.clae.2015.09.007

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  2 in total

Review 1.  Current perspectives in the management of keratoconus with contact lenses.

Authors:  Li Lim; Elizabeth Wen Ling Lim
Journal:  Eye (Lond)       Date:  2020-07-08       Impact factor: 3.775

2.  Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK.

Authors:  XiaoBo Zheng; WeiHua Yang; LiFang Huang; JunJie Wang; Si Cao; Brendan Geraghty; YiPing Zhao; QinMei Wang; FangJun Bao; Ahmed Elsheikh
Journal:  Sci Rep       Date:  2017-06-09       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.