Literature DB >> 26474506

Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms.

Nicolas Attigah1, Kyriakos Oikonomou2, Ulf Hinz3, Thomas Knoch4, Serdar Demirel1, Eric Verhoeven2, Dittmar Böckler5.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the radiation exposure of vascular surgeons' eye lens and fingers during complex endovascular procedures in modern hybrid operating rooms.
METHODS: Prospective, nonrandomized multicenter study design. One hundred seventy-one consecutive patients (138 male; median age, 72.5 years [interquartile range, 65-77 years]) underwent an endovascular procedure in a hybrid operating room between March 2012 and July 2013 in two vascular centers. The dose-area product (DAP), fluoroscopy time, operating time, and amount of contrast dye were registered prospectively. For radiation dose recordings, single-use dosimeters were attached at eye level and to the ring finger of the hand next to the radiation field of the operator for each endovascular procedure. Dose recordings were evaluated by an independent institution. Before the study, precursory investigations were obtained to simulate the radiation dose to eye lens and fingers with an Alderson phantome (RSD, Long Beach, Calif).
RESULTS: Interventions were classified into six treatment categories: endovascular repair of infrarenal abdominal aneurysm (n = 65), thoracic endovascular aortic repair (n = 32), branched endovascular aortic repair for thoracoabdominal aneurysms (n = 17), fenestrated endovascular aortic repair for complex abdominal aortic aneurysm, (n = 25), iliac branched device (n = 8), and peripheral interventions (n = 24). There was a significant correlation in DAP between both lens (P < .01; r = 0.55) and finger (P < .01; r = 0.56) doses. The estimated fluoroscopy time to reach a radiation threshold of 20 mSv/y was 1404.10 minutes (90% confidence limit, 1160, 1650 minutes). According to correlation of the lens dose with the DAP an estimated cumulative DAP of 932,000 mGy/m(2) (90% confidence limit, 822,000, 1,039,000) would be critical for a threshold of 20 mSv/y for the eyes.
CONCLUSIONS: Radiation protection is a serious issue for vascular surgeons because most complex endovascular procedures are delivering measurable radiation to the eyes. With the correlation of the DAP obtained in standard endovascular procedures a critical threshold of 20 mSv/y to the eyes can be predicted and thus an estimate of a potential harmful exposure to the eyes can be obtained.
Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26474506     DOI: 10.1016/j.jvs.2015.08.051

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  9 in total

1.  Treatment of cephalotuberosity fractures in elderly patients treated by reverse shoulder prosthesis: a study of functional results in relation to deltoid tension.

Authors:  Pierre-Sylvain Marcheix; Isaline Bazin; Guillaume Vergnenegre; Christian Mabit; Jean-Louis Charissoux
Journal:  Int Orthop       Date:  2019-11-08       Impact factor: 3.075

Review 2.  Physician and Patient Radiation Exposure During Endovascular Procedures.

Authors:  Andrew M Goldsweig; J Dawn Abbott; Herbert D Aronow
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-02

Review 3.  [Summary of the S3 guideline on abdominal aortic aneurysm from an anesthesiological perspective].

Authors:  A Funk; A Walther
Journal:  Anaesthesist       Date:  2020-01       Impact factor: 1.041

4.  Radiation Awareness for Endovascular Abdominal Aortic Aneurysm Repair in the Hybrid Operating Room. An Instant Patient Risk Chart for Daily Practice.

Authors:  Quirina M de Ruiter; Crystel M Gijsberts; Constantijn E Hazenberg; Frans L Moll; Joost A van Herwaarden
Journal:  J Endovasc Ther       Date:  2017-04-10       Impact factor: 3.487

5.  Fistuloplasty using a radiation-and-time-saving sheathless balloon catheter.

Authors:  Joel Crawford; Angela Kokkosis; Pamela Kim; Antonios Gasparis; Nicos Labropoulos
Journal:  J Vasc Access       Date:  2018-10-14       Impact factor: 2.283

Review 6.  Artificial vascular models for endovascular training (3D printing).

Authors:  Inez Torres; Nelson De Luccia
Journal:  Innov Surg Sci       Date:  2018-08-11

7.  Electroanatomical Navigation to Minimize Contrast Medium or X-Rays During Stenting: Insights From an Experimental Model.

Authors:  Jean-François Dorval; Louis-Philippe Richer; Luc Soucie; Luke C McSpadden; Adam Hoopai; Stéphanie Tan; Nick E J West; E Marc Jolicoeur
Journal:  JACC Basic Transl Sci       Date:  2021-11-05

Review 8.  Radiation protection of the eye lens in medical workers--basis and impact of the ICRP recommendations.

Authors:  Stephen Gr Barnard; Elizabeth A Ainsbury; Roy A Quinlan; Simon D Bouffler
Journal:  Br J Radiol       Date:  2016-02-01       Impact factor: 3.039

9.  Development of Neuromonitoring Pedicle Screw - Results of Electrical Resistance and Neurophysiologic Test in Pig Model.

Authors:  Woo-Seok Bang; Jonghoo Park; Kyoung-Tae Kim; Dae-Chul Cho; K Daniel Riew; Du-Hwan Kim; In-Bo Han; Seung-Jae Hyun; Do-Heum Yoon; Young-Baeg Kim
Journal:  Neurospine       Date:  2020-11-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.