Literature DB >> 26473996

Running mechanical alterations during repeated treadmill sprints in hot versus hypoxic environments. A pilot study.

Olivier Girard1,2, Franck Brocherie1, Jean-Benoit Morin3, Grégoire P Millet1.   

Abstract

We determined if performance and mechanical running alterations during repeated treadmill sprinting differ between severely hot and hypoxic environments. Six male recreational sportsmen (team- and racket-sport background) performed five 5-s sprints with 25-s recovery on an instrumented treadmill, allowing the continuous (step-by-step) measurement of running kinetics/kinematics and spring-mass characteristics. These were randomly conducted in control (CON; 25°C/45% RH, inspired fraction of oxygen = 20.9%), hot (HOT; 38°C/21% RH, inspired fraction of oxygen = 20.9%; end-exercise core temperature: ~38.6°C) and normobaric hypoxic (HYP, 25°C/45% RH, inspired fraction of oxygen = 13.3%/simulated altitude of ~3600 m; end-exercise pulse oxygen saturation: ~84%) environments. Running distance was lower (P < 0.05) in HOT compared to CON and HYP for the first sprint but larger (P < 0.05) sprint decrement score occurred in HYP versus HOT and CON. Compared to CON, the cumulated distance covered over the five sprints was lower (P < 0.01) in HYP but not in HOT. Irrespective of the environmental condition, significant changes occurred from the first to the fifth sprint repetitions (all three conditions compounded) in selected running kinetics (mean horizontal forces, P < 0.01) or kinematics (contact and swing times, both P < 0.001; step frequency, P < 0.001) and spring-mass characteristics (vertical stiffness, P < 0.001; leg stiffness, P < 0.01). No significant interaction between sprint number and condition was found for any mechanical data. Preliminary evidence indicates that repeated-sprint ability is more impaired in hypoxia than in a hot environment, when compared to a control condition. However, as sprints are repeated, mechanical alterations appear not to be exacerbated in severe (heat, hypoxia) environmental conditions.

Entities:  

Keywords:  Heat; hypoxia; repeated-sprint ability; sprinting mechanics

Mesh:

Year:  2015        PMID: 26473996     DOI: 10.1080/02640414.2015.1101482

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  6 in total

Review 1.  Effects of Altitude/Hypoxia on Single- and Multiple-Sprint Performance: A Comprehensive Review.

Authors:  Olivier Girard; Franck Brocherie; Grégoire P Millet
Journal:  Sports Med       Date:  2017-10       Impact factor: 11.136

2.  The Methodological Quality of Studies Investigating the Acute Effects of Exercise During Hypoxia Over the Past 40 years: A Systematic Review.

Authors:  Erich Hohenauer; Livia Freitag; Miriam Herten; Julia Siallagan; Elke Pollock; Wolfgang Taube; Ron Clijsen
Journal:  Front Physiol       Date:  2022-06-16       Impact factor: 4.755

3.  Acute performance and physiological responses to repeated-sprint exercise in a combined hot and hypoxic environment.

Authors:  Keiichi Yamaguchi; Nobukazu Kasai; Nanako Hayashi; Haruka Yatsutani; Olivier Girard; Kazushige Goto
Journal:  Physiol Rep       Date:  2020-06

4.  The Use of Technology to Protect the Health of Athletes During Sporting Competitions in the Heat.

Authors:  Borja Muniz-Pardos; Shaun Sutehall; Konstantinos Angeloudis; Jonathan Shurlock; Yannis P Pitsiladis
Journal:  Front Sports Act Living       Date:  2019-10-03

5.  Relationship between Reactive Strength and Leg Stiffness at Submaximal Velocity: Effects of Age on Distance Runners.

Authors:  Diego Jaén-Carrillo; Antonio Cartón-Llorente; Demetrio Lozano-Jarque; Alberto Rubio-Peirotén; Luis E Roche-Seruendo; Felipe García-Pinillos
Journal:  Int J Environ Res Public Health       Date:  2021-06-26       Impact factor: 3.390

Review 6.  The Training and Development of Elite Sprint Performance: an Integration of Scientific and Best Practice Literature.

Authors:  Thomas Haugen; Stephen Seiler; Øyvind Sandbakk; Espen Tønnessen
Journal:  Sports Med Open       Date:  2019-11-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.