Literature DB >> 26470037

Delay-encoded transmission and image reconstruction method in synthetic transmit aperture imaging.

Ping Gong, Michael C Kolios, Yuan Xu.   

Abstract

Synthetic transmit aperture (STA) imaging systems usually have a lower SNR compared with conventional Bmode ultrasound systems because only one or a small number of elements are selected for each transmission in STA. Here we propose delay-encoded synthetic transmit aperture (DE-STA) imaging to encode all the transmission elements to increase the SNR of the pre-beamformed RF signals. The encoding scheme is similar to the Hadamard encoding. However, in each transmission of DE-STA imaging, selected transmitting elements are delayed by a half period of the ultrasound wave relative to the rest transmitting elements, rather than using a pulse inversion as in the Hadamard encoding sequence. After all the transmission events, a decoding process in the temporal frequency domain is applied to the acquired RF signals to recover the equivalent traditional STA signals with a better SNR. The proposed protocol is tested with simulated data (using Field II) and experimental data acquired with a commercial linear array imaging system (Ultrasonix RP). The results from both the simulations and the experiments demonstrate increased SNR of pre-beamformed RF signals and improved image quality in terms of peak signal-to-noise ratio (PSNR), resolution and contrast-to-noise ratio compared with traditional STA. The lateral resolution (as assessed by a wire target) of DESTA imaging is improved by 28% and the PSNR of the wire is increased by 7 dB, respectively, compared with traditional STA imaging. The proposed image reconstruction framework can also be extended to other transmission protocols.

Mesh:

Year:  2015        PMID: 26470037     DOI: 10.1109/TUFFC.2015.007005

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  6 in total

1.  Simultaneous Axial Multifocal Imaging Using a Single Acoustical Transmission: A Practical Implementation.

Authors:  Asaf Ilovitsh; Tali Ilovitsh; Josquin Foiret; Douglas N Stephens; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-05       Impact factor: 2.725

2.  Extending Retrospective Encoding for Robust Recovery of the Multistatic Data Set.

Authors:  Rehman Ali; Carl D Herickhoff; Dongwoon Hyun; Jeremy J Dahl; Nick Bottenus
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-12-23       Impact factor: 2.725

3.  Comparison of virtual source synthetic aperture beamforming with an element-based model.

Authors:  Nick Bottenus
Journal:  J Acoust Soc Am       Date:  2018-05       Impact factor: 1.840

4.  Recovery of the Complete Data Set From Focused Transmit Beams.

Authors:  Nick Bottenus
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-01       Impact factor: 2.725

5.  Resolution and Speckle Reduction in Cardiac Imaging.

Authors:  Nick Bottenus; Melissa LeFevre; Jayne Cleve; Anna Lisa Crowley; Gregg Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-03-26       Impact factor: 2.725

6.  Pixel-Oriented Adaptive Apodization for Plane-Wave Imaging Based on Recovery of the Complete Dataset.

Authors:  Qi You; Zhijie Dong; Matthew R Lowerison; Pengfei Song
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-01-27       Impact factor: 2.725

  6 in total