Line Integral Alternating Minimization Algorithm for Dual-Energy X-Ray CT Image Reconstruction.

Yaqi Chen, Joseph A O'Sullivan, David G Politte, Joshua D Evans, Dong Han, Bruce R Whiting, Jeffrey F Williamson.   

Abstract

We propose a new algorithm, called line integral alternating minimization (LIAM), for dual-energy X-ray CT image reconstruction. Instead of obtaining component images by minimizing the discrepancy between the data and the mean estimates, LIAM allows for a tunable discrepancy between the basis material projections and the basis sinograms. A parameter is introduced that controls the size of this discrepancy, and with this parameter the new algorithm can continuously go from a two-step approach to the joint estimation approach. LIAM alternates between iteratively updating the line integrals of the component images and reconstruction of the component images using an image iterative deblurring algorithm. An edge-preserving penalty function can be incorporated in the iterative deblurring step to decrease the roughness in component images. Images from both simulated and experimentally acquired sinograms from a clinical scanner were reconstructed by LIAM while varying the regularization parameters to identify good choices. The results from the dual-energy alternating minimization algorithm applied to the same data were used for comparison. Using a small fraction of the computation time of dual-energy alternating minimization, LIAM achieves better accuracy of the component images in the presence of Poisson noise for simulated data reconstruction and achieves the same level of accuracy for real data reconstruction.

Entities:  

Mesh:

Year:  2015        PMID: 26469126      PMCID: PMC6394417          DOI: 10.1109/TMI.2015.2490658

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation.

Authors:  Dong Han; Jeffrey V Siebers; Jeffrey F Williamson
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Algorithm-enabled partial-angular-scan configurations for dual-energy CT.

Authors:  Buxin Chen; Zheng Zhang; Dan Xia; Emil Y Sidky; Xiaochuan Pan
Journal:  Med Phys       Date:  2018-03-30       Impact factor: 4.071

3.  Technical Note: On the accuracy of parametric two-parameter photon cross-section models in dual-energy CT applications.

Authors:  Dong Han; Mariela A Porras-Chaverri; Joseph A O'Sullivan; David G Politte; Jeffrey F Williamson
Journal:  Med Phys       Date:  2017-04-25       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.