Literature DB >> 26469077

Comparison of Methods to Predict Residual Astigmatism After Intraocular Lens Implantation.

Adi Abulafia, Warren E Hill, Maria Franchina, Graham D Barrett.   

Abstract

PURPOSE: To evaluate and compare the accuracy of three toric intraocular lens (IOL) calculators using keratometry measurements derived from the anterior corneal curvature and direct measurements of the posterior corneal curvature.
METHODS: Postoperative corneal astigmatism was measured by the IOLMaster (Carl Zeiss Meditec, Jena, Germany) and Pentacam (Oculus Optikgeräte, Wetzlar, Germany). The data were processed by the Alcon, Holladay, and Barrett toric IOL calculators. The error in predicted residual astigmatism (PredRA) was calculated by subtracting the PredRA from the postoperative subjective refraction by vector analysis.
RESULTS: The centroid errors in PredRA were against-the-rule (ATR) with the Alcon (0.56 diopters [D]) and Holladay (0.55 D) toric calculators using the IOLMaster (Carl Zeiss Meditec, Jena, Germany) measurements. The centroid errors in PredRA were lower when Pentacam (Oculus Optikgeräte, Wetzlar, Germany) measurements were used (0.38 D, ATR). The Barrett toric calculator using the IOLMaster measurements had the lowest centroid errors in PredRA (0.02 D, P < .001) and achieved the most accurate results: 75.8% and 92.9% of eyes were within 0.50 and 0.75 D of the PredRA, respectively.
CONCLUSIONS: The prediction of the postoperative astigmatic outcome can be improved by using appropriate methods of adjustment for posterior corneal astigmatism. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26469077     DOI: 10.3928/1081597X-20150928-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  13 in total

1.  Accuracy of corneal astigmatism correction with two Barrett Toric calculation methods.

Authors:  Jun Yang; Hong Zhang; Xiao-Tong Yang; Fang Tian; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

2.  Refractive Outcomes for Cataract Surgery With Toric Intraocular Lenses at a Veterans Affairs Medical Center.

Authors:  Elaine M Tran; Kevin S Tang; Allison J Chen; Michael L Chen; David R Rivera; Jorge J Rivera; Paul B Greenberg
Journal:  Fed Pract       Date:  2020-03

3.  Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer.

Authors:  Yukitaka Danjo; Reina Ohji; Sayo Maeno
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-26       Impact factor: 3.535

4.  Comparison of Barrett Toric Calculations Using Measured and Predicted Posterior Corneal Astigmatism in Cataract Surgery Patients.

Authors:  Mark K Lukewich; Fahmeeda Murtaza; Sohel Somani; Eric S Tam; Hannah H Chiu
Journal:  Clin Ophthalmol       Date:  2022-06-01

5.  Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

Authors:  Youngsub Eom; Dongok Ryu; Dae Wook Kim; Seul Ki Yang; Jong Suk Song; Sug-Whan Kim; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-08-19       Impact factor: 3.117

6.  Evaluation of Astigmatism-Correcting Efficiency and Rotational Stability after Cataract Surgery with a Double-Loop Haptic Toric Intraocular Lens: A 1-Year Follow-Up.

Authors:  Ladislav Viktor Nováček; Marie Němcová; Kateřina Tyx; Kristýna Lahodová; Leoš Rejmont; Pavel Rozsíval; Pavel Studený
Journal:  Biomed Hub       Date:  2021-02-17

7.  Comparison of Barrett and Emmetropia Verifying Optical Toric Calculators.

Authors:  Seth M Pantanelli; Ashley Sun; Neal Kansara; Gerard Smits
Journal:  Clin Ophthalmol       Date:  2022-01-25

8.  Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2016-11-03

9.  Comparison of astigmatism prediction error taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens implantation.

Authors:  Dae-Young Park; Dong Hui Lim; Sungsoon Hwang; Joo Hyun; Tae-Young Chung
Journal:  BMC Ophthalmol       Date:  2017-08-24       Impact factor: 2.209

10.  Comparison of Two Toric IOL Calculation Methods.

Authors:  C Kern; K Kortüm; M Müller; A Kampik; S Priglinger; W J Mayer
Journal:  J Ophthalmol       Date:  2018-01-10       Impact factor: 1.909