Influence on Visual Quality of Intraoperative Orientation of Asymmetric Intraocular Lenses.

Sergio Bonaque-González, Susana Ríos, Alfredo Amigó, Norberto López-Gil.   

Abstract

PURPOSE: To evaluate visual quality when changing the intraocular orientation of the Lentis Mplus LS-312MF nonrotational symmetric +3.00 diopters aspheric multifocal intraocular lens ([IOL] Oculentis GmbH, Berlin, Germany) in normal eyes.
METHODS: An artificial eye was used to measure the in vitro wavefront of the IOL. The corneal topography of 20 healthy patients was obtained. For each eye, a computational analysis simulated the implantation of the IOL. The modulation transfer function (MTF) and an image quality parameter (visually modulated transfer function [VSMTF] metric) were calculated for a 5.0-mm pupil and for three conditions: distance, intermediate, and near vision. The procedure was repeated for each eye after a rotation of the IOL with respect to the cornea from 0° to 360° in 1° steps.
RESULTS: Statistical analysis showed significant differences in mean VSMTF values between orientations for distance vision. Optimal orientation of the IOL (different for each eye) showed a mean improvement of 58% ± 19% (range: 20% to 121%) in VSMTF values with respect to the worst possible orientation. For these orientations, intermediate and near vision quality were statistically indistinguishable. The MTFs were different between orientations, showing a mean difference of approximately 5 cycles per degree in the maximum spatial frequencies that can be transferred between the best and the worst orientations for distance vision.
CONCLUSIONS: The results suggest that implantation of this nonrotational symmetric IOL should improve visual outcomes if it is oriented to coincide with a customized meridian. A simple, practical method is proposed to find an approximation to the angle that an Mplus IOL should be inserted. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26469073     DOI: 10.3928/1081597X-20150922-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  Perceived image quality with simulated segmented bifocal corrections.

Authors:  Carlos Dorronsoro; Aiswaryah Radhakrishnan; Pablo de Gracia; Lucie Sawides; Susana Marcos
Journal:  Biomed Opt Express       Date:  2016-10-03       Impact factor: 3.732

2.  Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation.

Authors:  Hungwon Tchah; Kiyeun Nam; Aeri Yoo
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

3.  The optics of the human eye at 8.6 µm resolution.

Authors:  Sergio Bonaque-González; Juan M Trujillo-Sevilla; Miriam Velasco-Ocaña; Óscar Casanova-González; Miguel Sicilia-Cabrera; Alex Roqué-Velasco; Sabato Ceruso; Ricardo Oliva-García; Javier Martín-Hernández; Oscar Gomez-Cardenes; José G Marichal-Hernández; Damien Gatinel; Jack T Holladay; José M Rodríguez-Ramos
Journal:  Sci Rep       Date:  2021-12-02       Impact factor: 4.379

4.  Long-term clinical outcomes obtained with bilateral implantation of a multifocal intraocular lens through two different-sized corneal incisions.

Authors:  Efthymios Karmiris; Evangelia Chalkiadaki; Evangelia Papakonstantinou; Ilias Georgalas
Journal:  Saudi J Ophthalmol       Date:  2022-08-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.