Long-term effectiveness and safety of the sirolimus-eluting BiOSS LIM® dedicated bifurcation stent in the treatment of distal left main stenosis: an international registry.

Robert J Gil1, Jacek Bil, Maik J Grundeken, Luis A Iñigo Garcia, Dobrin Vassilev, Adam Kern, Tomasz Pawłowski, Joanna J Wykrzykowska, Patrick W Serruys.   

Abstract

AIMS: The aim of this study was to assess prospectively the effectiveness and safety of a new version of the dedicated bifurcation BiOSS stent, the sirolimus-eluting BiOSS LIM, for the treatment of distal left main (LM) stenosis. METHODS AND
RESULTS: This was a prospective international registry which enrolled patients with NSTE-ACS or stable angina. Provisional T-stenting was the mandated strategy. The primary endpoint was the cumulative rate of cardiac death, myocardial infarction (MI) and target lesion revascularisation (TLR) at 12 months. Twelve-month quantitative coronary angiography endpoints included late lumen loss and percent diameter stenosis. A total of 74 patients with distal LM stenosis were enrolled. Seventy-three of the 74 patients (aged 67±9 years, 23% women, 20.3% NSTE-ACS, SYNTAX score 22.4±4.4) were successfully treated with the BiOSS LIM stent, with additional side branch placement of regular DES in 11 patients (14.9%). Periprocedural MI occurred in one (1.4%) patient. The 12-month MACE rate was 9.5% without cardiac death or definite stent thrombosis. TLR and MI rates were 6.8% (n=5) and 2.7% (n=2), respectively.
CONCLUSIONS: The use of the BiOSS LIM dedicated bifurcation stent for the treatment of distal LM stenosis was feasible and safe, with promising long-term clinical effectiveness.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26465375     DOI: 10.4244/EIJY15M10_05

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  3 in total

1.  The Need For Dedicated Bifurcation Stents: A Critical Analysis.

Authors:  Maciej Lesiak
Journal:  Interv Cardiol       Date:  2016-10

2.  Rationale and design of the randomized, multicenter, open-label, controlled POLBOS 3 trial aimed to compare regular drug-eluting stents versus the dedicated coronary bifurcation sirolimus-eluting BiOSS LIM C stent.

Authors:  Robert J Gil; Tomasz Pawłowski; Jacek Legutko; Maciej Lesiak; Adam Witkowski; Mariusz Gąsior; Adam Kern; Jacek Bil
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

3.  12-month intravascular ultrasound observations from BiOSS® first-in-man studies.

Authors:  Robert J Gil; Jacek Bil; Ricardo A Costa; Katarzyna E Gil; Dobrin Vassiliev
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-17       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.