Literature DB >> 26465253

Visual Outcomes After Cataract Surgery: Multifocal Versus Monofocal Intraocular Lenses.

Sunil Shah, Cristina Peris-Martinez, Thomas Reinhard, Paolo Vinciguerra.   

Abstract

PURPOSE: To evaluate visual outcomes, spectacle independence, and quality of life among nonastigmatic and astigmatic patients who received AcrySof IQ ReSTOR toric or nontoric multifocal intraocular lenses (IOLs) (Alcon Laboratories, Fort Worth, TX) compared with those who received commercially available nontoric monofocal IOLs after bilateral cataract removal.
METHODS: This randomized, patient- and observer-technician-masked study was conducted at 20 sites in Europe. Patients were randomized to receive monofocal (nontoric only) or multifocal (nontoric or toric, as needed) IOLs. Primary efficacy endpoints included percentage of patients achieving binocular uncorrected distance and near acuity of 0.1 logMAR or better (20/25 Snellen), spectacle independence, and scores on the National Eye Institute Refractive Error and Quality of Life questionnaire domains. Safety endpoints included adverse events and refractive error within 0.5 and 1.0 diopters.
RESULTS: In the multifocal group (n = 108) versus the monofocal group (n = 100), significantly more patients achieved uncorrected distance and near acuity of 0.1 logMAR or better (45.7% vs 2.1%; P < .0001) and spectacle independence (73.3% vs 25.3%; P < .0001) at 6 months. The percentage of patients who achieved uncorrected distance visual acuity of 20/40 or better at 6 months was 92% in the multifocal group and 97% in the monofocal group. National Eye Institute Refractive Error and Quality of Life scores were significantly better for dependence on correction in the multifocal group (P < .0001) and for glare in the monofocal group (P = .0157); other domain scores were similar between groups. No significant trends in study device-related adverse events were observed.
CONCLUSIONS: Monofocal and multifocal IOLs provided good clinical outcomes. More patients receiving multifocal IOLs attained better uncorrected visual acuity at a range of distances and spectacle independence compared with patients who received monofocal IOLs. Monofocal IOLs were associated with better patient-reported scores for glare compared with multifocal IOLs; however, scores for patient satisfaction were significantly better in the multifocal group. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26465253     DOI: 10.3928/1081597X-20150611-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  20 in total

Review 1.  Personalized aspheric intraocular lens implantation based on corneal spherical aberration: a review.

Authors:  Wei Du; Wei Lou; Qiang Wu
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

2.  Toric IOL positioning with a no-touch head-up display axis alignment.

Authors:  J Luebke; D Boehringer; P Maier; T Reinhard; P Eberwein
Journal:  Int Ophthalmol       Date:  2019-11-23       Impact factor: 2.031

3.  Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract Surgery: A Systematic Review and Bayesian Network Meta-analysis.

Authors:  Jeong-Yeon Cho; Yeo Kyoung Won; Jongyeop Park; Jin Hyun Nam; Ji-Yoon Hong; Serim Min; Nahyun Kim; Tae-Young Chung; Eui-Kyung Lee; Sun-Hong Kwon; Dong Hui Lim
Journal:  JAMA Ophthalmol       Date:  2022-09-22       Impact factor: 8.253

4.  Difference in Quality of Vision Outcome among Extended Depth of Focus, Bifocal, and Monofocal Intraocular Lens Implantation.

Authors:  Chen-Cheng Chao; Hung-Yuan Lin; Chia-Yi Lee; Elsa Lin-Chin Mai; Ie-Bin Lian; Chao-Kai Chang
Journal:  Healthcare (Basel)       Date:  2022-05-28

5.  Clinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF).

Authors:  Banu Torun Acar; Erkan Duman; Saban Simsek
Journal:  BMC Ophthalmol       Date:  2016-11-29       Impact factor: 2.209

6.  Cataract Surgery in Patients with a Previous History of KAMRA Inlay Implantation: A Case Series.

Authors:  Majid Moshirfar; Tyler S Quist; David F Skanchy; Steven H Linn; Jordan Desautels; Phillip C Hoopes
Journal:  Ophthalmol Ther       Date:  2017-04-25

7.  Rotational stability and visual performance 3 months after bilateral implantation of a new toric extended range of vision intraocular lens.

Authors:  Kjell Gunnar Gundersen
Journal:  Clin Ophthalmol       Date:  2018-07-18

8.  Trifocal versus Bifocal Diffractive Intraocular Lens Implantation after Cataract Surgery or Refractive Lens Exchange: a Meta-analysis.

Authors:  Chang Ho Yoon; In-Soo Shin; Mee Kum Kim
Journal:  J Korean Med Sci       Date:  2018-09-27       Impact factor: 2.153

9.  Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation.

Authors:  Leopoldo Spadea; Maria Ilaria Giannico; Martina Formisano; Ludovico Alisi
Journal:  Ther Clin Risk Manag       Date:  2021-07-16       Impact factor: 2.423

10.  Clinical Results of Diffractive, Refractive, Hybrid Multifocal, and Monofocal Intraocular Lenses.

Authors:  Agnieszka Dyrda; Ana Martínez-Palmer; Daniel Martín-Moral; Amanda Rey; Antonio Morilla; Miguel Castilla-Martí; Janny Aronés-Santivañez
Journal:  J Ophthalmol       Date:  2018-06-25       Impact factor: 1.909

View more