Incidence, predictors, and outcome of inadvertent malposition of transvenous pacing or defibrillation lead in the left heart.

Marc-Alexander Ohlow1, Marcus Roos2, Bernward Lauer3, Hubertus Von Korn4, Johann Christoph Geller5.   

Abstract

AIMS: Inadvertent lead malposition (ILM) in the left heart is a potential cause of thromboembolism and, therefore, a complication of heart rhythm device implantation [HRDI: pacemaker, implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy (CRT)]. The aim of the study was to report the incidence and clinical outcome of ILM. METHODS AND
RESULTS: Postoperative lateral and posterior-anterior chest X-rays of all consecutive patients undergoing HRDI from 2007 through 2012 were retrospectively analysed. During the study period, 2579 patients underwent HRDI at our institution. ILM was present in six patients (0.34%, 50% male, mean age 71.5 ± 9.4 years). In one and four patients, malposition was in the left atrium and ventricle, respectively. In one case, the RV-lead was placed in a coronary sinus branch. In four patients, ILM was detected intra-operatively or in the early postoperative period. In the remaining two patients, malposition was not recognized and they suffered cerebral embolism 4 months and 1 year after implantation. ILM was corrected during the same hospital stay (four cases), or during follow-up by percutaneous extraction (two cases). Patients with ILM had significantly more scoliosis (16.7 vs. 0.17%; P = 0.01), congenital heart disease (CHD: 33.3 vs. 0.4%; P = 0.003), or prior surgery for CHD (16.7 vs. 0.5%; P = 0.03). The likelihood of ILM was also increased when HRDI was performed by an inexperienced operator (<100 HRDI; P < 0.01).
CONCLUSION: The incidence of ILM was 0.34% in our series. Scoliosis, CHD, prior correction of CHD, and limited operator experience were identified as risk factors. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Complication; Congenital heart disease; Implantable defibrillator; Lead malposition; Operator experience; Pacemaker

Mesh:

Year:  2015        PMID: 26462705     DOI: 10.1093/europace/euv270

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  9 in total

1.  A pacemaker lead in the left ventricle: An "unexpected" finding?

Authors:  Chiara Rovera; Pier Giorgio Golzio; Giuditta Corgnati; Valentina Conti; Erica Franco; Simone Frea; Claudio Moretti
Journal:  J Cardiol Cases       Date:  2019-09-12

2.  Percutaneous extraction of a malpositioned subclavian arterial pacing lead using the retained wire technique and a vascular closure device: a case report.

Authors:  Primero Ng; Vince Paul; Sharad Shetty; James Lambert
Journal:  Eur Heart J Case Rep       Date:  2022-06-10

3.  Critical analysis of ineffective post implantation implantable cardioverter-defibrillator-testing.

Authors:  Markus Roos; J Christoph Geller; Marc-Alexander Ohlow
Journal:  World J Cardiol       Date:  2017-02-26

4.  Left ventricular lead misplacement discovered a decade after cardiac resynchronization therapy-defibrillator implantation: a case report.

Authors:  Lisa W M Leung; Banu Evranos; Rajay Narain; Mark M Gallagher
Journal:  Eur Heart J Case Rep       Date:  2018-06-21

5.  Inadvertent defibrillator lead placement into the left ventricle after MitraClip implantation: A case report.

Authors:  Giuseppe Santarpia; Francesco Passafaro; Eugenia Pasceri; Annalisa Mongiardo; Antonio Curcio; Ciro Indolfi
Journal:  Medicine (Baltimore)       Date:  2018-05       Impact factor: 1.889

6.  Early and Late Effects of Cardiac Resynchronization Therapy in Adult Congenital Heart Disease.

Authors:  Yanrong Yin; Konstantinos Dimopoulos; Eriko Shimada; Karen Lascelles; Samuel Griffiths; Tom Wong; Michael A Gatzoulis; Sonya V Babu-Narayan; Wei Li
Journal:  J Am Heart Assoc       Date:  2019-10-28       Impact factor: 5.501

7.  Diagnosis and management of inadvertently placed pacemaker lead in the left ventricle following sinus venosus atrial septal defect repair surgery.

Authors:  Meron Teshome; Ikechukwu Ifedili; Mannu Nayyar; Yehoshua Levine; Anthony Holden; Neeraja Yedlapati; Rajesh Kabra
Journal:  HeartRhythm Case Rep       Date:  2020-02-08

8.  Malpositioned endocardial left ventricular pacing lead extraction with transcatheter cerebral embolic protection in the setting of multiple prior embolic strokes.

Authors:  Amit Thosani; Amresh Raina; Emerson Liu; David Lasorda; John Chenarides
Journal:  HeartRhythm Case Rep       Date:  2019-08-28

9.  Left ventricular pacemaker wire through patent foramen ovale.

Authors:  Nicholas Suraci; Saberio Lo Presti; Gilberto George Concepcion; Orlando Santana
Journal:  Ann Card Anaesth       Date:  2020 Oct-Dec
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.