Literature DB >> 26462247

Impact of UV-H2O2 Advanced Oxidation and Aging Processes on GAC Capacity for the Removal of Cyanobacterial Taste and Odor Compounds.

Arash Zamyadi1, Emma Sawade2, Lionel Ho2, Gayle Newcombe2, Ron Hofmann3.   

Abstract

Cyanobacteria and their taste and odor (T&O) compounds are a growing concern in water sources globally. Geosmin and 2-methylisoborneol (MIB) are the most commonly detected T&O compounds associated with cyanobacterial presence in drinking water sources. The use of ultraviolet and hydrogen peroxide (H2O2) as an advanced oxidation treatment for T&O control is an emerging technology. However, residual H2O2 (>80% of the initial dose) has to be removed from water prior final disinfection. Recently, granular activated carbon (GAC) is used to remove H2O2 residual. The objective of this study is to assess the impact of H2O2 quenching and aging processes on GAC capacity for the removal of geosmin and MIB. Pilot columns with different types of GAC and presence/absence of H2O2 have been used for this study. H2O2 removal for the operational period of 6 months has no significant impact on GAC capacity to remove the geosmin and MIB from water.

Entities:  

Keywords:  GAC; UV–H2O2; advanced oxidation; cyanobacteria; granular activated carbon; taste and odor; water treatment

Year:  2015        PMID: 26462247      PMCID: PMC4592064          DOI: 10.4137/EHI.S29431

Source DB:  PubMed          Journal:  Environ Health Insights        ISSN: 1178-6302


Introduction

Cyanobacteria, also known as blue-green algae, are prokaryotic photosynthetic microorganisms present in both marine and freshwater sources.1–3 Cyanobacterial nitrogen-fixing capacity (the ability to convert atmospheric N2 to NH3) and their contribution to global soil and water fertility have long been recognized.1,2,4 They have shown an exceptional capability to adapt to the global changing environment and grow well in water bodies impacted by human activities and climate change.5–7 Nutrient load from agricultural watersheds8,9 to water bodies is a major cause of cyanobacterial proliferation.8,10–12 Additionally, warmer global temperatures, low water level in lakes, low river flows, and reduced water quality associated with drought conditions and climate change favor the growth of cyanobacteria.6,13 As a result of all of these factors, issues associated with cyanobacteria in water treatment for human consumption are increasing worldwide even in more temperate regions like Canada.7,14,15 The major water quality implications of cyanobacterial blooms for the water industry are (a) production of cellular metabolites, which can cause esthetic issues, eg, compounds that impart taste and odor (T&O); (b) release of toxic cellular metabolites (cyanotoxins), which can severely impact aquatic, animals’, and human health; and (c) treatment process disturbance because of the breakthrough of cells into plants.1,14,16–19 Toxic effects of detected cyanotoxins (mainly microcystins, nodularins, anatoxins, cylindrospermopsin, and saxitoxins) include hepatotoxicity, liver cancer, neurotoxicity, cytotoxicity, genotoxicity, dermatotoxicity, and human gastroenteritis.1,2,10,16–18 In Australia and Canada, many troublesome species of cyanobacteria proliferate in drinking water sources, in particular, species of Dolichospermum, Microcystis, Aphanizomenon, Anabaena, Pseudanabaena, and Cylindrospermopsis.10,15,20 These cyanobacteria have the potential to produce the T&O compounds and cyanotoxins.2,10,15,19 Geosmin and 2-methylisoborneol (MIB) are the most commonly detected T&O compounds associated with cyanobacterial presence in drinking water sources.19,21–23 Their characteristics and chemical structure are shown in Figure 1. Additionally, production of neurotoxic anatoxins and hepatotoxic microcystins by T&O-producing species has been reported.22 The presence of geosmin and MIB has been mainly recorded during the warm summer season and/or early autumn during bloom lysis period.24 Hence, cyanobacterial T&O issues are perceived as a temporary issue. Consequently, management and treatment adjustment information are focused on temporary options, such as addition of powdered activated carbon only during the bloom season and/or detection of a bloom event.19 However, full-year monitoring results have documented the presence of these T&O compounds and their producing cells during cold season or pre/postbloom season.25,26 Furthermore, assessment of existing treatment trains for the removal of harmful cyanobacterial metabolites has demonstrated the vulnerability of these barriers to climate change scenarios.27
Figure 1

Chemical structure of (A) geosmin and (B) MIB.21,22

Cyanobacterial T&O compounds are detectable by humans in very low concentrations, as low as 10 ng/L.19 Additionally, conventional treatment options including chlorination are inefficient for their removal.21,28 Preoxidation using strong oxidant agents, such as ozone, advanced oxidation techniques, and/or adsorptive barriers, eg, activated carbon, is required for their efficient removal from water.21,28,29 The use of ultraviolet light (UV) and hydrogen peroxide (H2O2) as an advanced oxidation treatment for T&O control is an emerging technology.30,31 A major challenge associated with UV–H2O2 is that the majority (>80%) of the applied H2O2 remains in the water following UV–H2O2 treatment.31 The residual H2O2 has to be removed prior to disinfection process as it exerts a strong chlorine demand.31–33 Unsuccessful removal of H2O2 post UV–H2O2 advanced oxidation process (AOP) and consequent breakthrough of H2O2 residual to chlorination process would (a) compromise the final disinfection of water prior distribution and (b) lead to insufficient (ie, below regulation) chlorine residual within distribution system. Granular activated carbon (GAC), which is a strong adsorbent and is used for removal of a wide range of contaminants via adsorption,34 can also serve as a catalyst or catalyst support for H2O231,35,36 decomposition. Successful H2O2 decomposition using GAC has been reported by previous publications.36–39 Metz et al.40 have reported that GAC can quench excess H2O2 while removing unexpected degradation products in drinking water treatment. Owing to the recent nature of this practice, prior operational experiences regarding H2O2 removal using GAC are limited.31,36 Furthermore, the H2O2 quenching impact on GAC capacity to further remove T&O compounds from water is unknown. This becomes a pertinent question for utilities where H2O2 is not dosed continuously throughout the year, and the T&O episodes have been documented in so-called off-season, ie, nonbloom season. Water utilities need to learn about the impact of H2O2 on GAC capacity to remove T&O and support biofilm, post quenching period. Hence, the objective of this study is to assess the impact of H2O2 removal post UV–H2O2 advanced oxidation and aging processes (with and without advanced oxidation prior to GAC) on GAC capacity for the removal of T&O compounds associated with cyanobacterial blooms.

Material and Methods

Pilot-scale GAC column testing in Canada

Multibarrier treatment system in a water treatment plant (WTP) in southern Ontario, Canada, includes the use of UV–H2O2 as an advanced oxidation treatment for T&O control (Fig. 2). The studied Canadian WTP is using GAC contactor to quench the residual H2O2 (Fig. 2). This pilot study was conducted to verify the performance of virgin and aged GAC (from quenching H2O2) at different depths for the removal of geosmin and MIB. Figure 3 demonstrates the schematic representation and the complete installation of the pilot setup that was installed in the studied Canadian WTP. The conditions of the columns are presented in Table 1.
Figure 2

Schematic representation of a UF and advanced oxidation plant in Ontario, Canada, and fate of algal cells and their by-products during the treatment: red square highlights the UV–H2O2 process that causes the residual H2O2 in the water post-AOP

Notes: *T&O, T&O compounds; **UV, ultraviolet advanced oxidation; and ***GAC, granular activated carbon.

Figure 3

Pilot setup at the Canadian plant: (A) schematic representation of the GAC columns and (B) general view of the fully built functional pilot and details of the sampling ports.

Table 1

Filter column conditions: pilot-scale (Canada) and laboratory-scale (Australia) parameters.

COLUMN CONDITIONSPILOT-SCALE (CANADA) PARAMETERSLABORATORY-SCALE (AUSTRALIA) PARAMETERS
Column internal diameter2.5 cm2.5 cm
Filter medium bed height128 cm15 cm
Empty bed contact time (EBCT)4.1 min15 min
The GACs were selected based on the material (Table 2) used for their preparation and also the current application of a particular type at the studied Canadian WTP. The characteristics of all GAC types are presented in Table 2. Treatment at the Canadian WTP (Fig. 2) comprised prechlorination in water temperatures >12 °C, ultrafiltration (UF), UV disinfection, injection of H2O2 during the algal bloom season (September to November), adsorption on GAC, and postchlorination. The plant draws water from the Canadian side of Lake Ontario, with average total organic carbon of 2.5 mg-C/L and 8.0 pH. There was negligible chlorine remaining by the time the water was directed onto the GAC pilot setup. The GAC contactors had been in service for approximately 1 year (130,000 bed volumes) and 2 years (260,000 bed volumes). The contactors had only been exposed to H2O2 on one occasion from September 2012 to November 2012 (approximately 32,000 bed volumes) with an average concentration of 4 mg/L H2O2 during that period. Therefore, the pilot GAC columns were aged using 4 mg/L of H2O2 for 3 and 6 months, 33,000 and 65,000 bed volumes, respectively.
Table 2

Detailed characteristics of the GAC used.

TEST (COLUMN) LOCATIONMATERIALSUPPLIER, PRODUCTPARTICLE SIZE (mm)IODINE NO. (mg/g)TCN NO.APPARENT DENSITY (g/L)
CanadaBituminous coal-based; catalyticCalgon, Centaur10447.8530
CanadaLignite coal-based; acid washedHD30006019.6421
CanadaCoconut-basedTN58617.1599
Canada and AustraliaBituminous coal-basedCalgon, F3000.8–1.08475.5501
AustraliaGACActicarb, GAC1000N0.5–0.7
An array of 16 pilot-scale glass columns containing virgin GACs was used for this test (Fig. 3). The 16 columns allowed for the testing of the GAC in duplicate. The columns were each 2.5 cm in diameter and 128 cm in depth to simulate the GAC depth of the full-scale plant. Quality control tests confirmed that such a diameter led to perfect plug flow conditions with no short-circuiting as a result of wall effects. Thus, these control tests confirmed that adsorption kinetics were consistent with the plug flow within the columns. Water obtained post UF membrane and prior to UV disinfection at the WTP was directed through pilot-scale GAC columns (Fig. 3) with empty bed contact time (EBCT) of 4.1 minutes (similar to the full-scale plant operational EBCT). Per each GAC type, two columns were aged using only the membrane permeate, and another two columns were aged using membrane permeate spiked with 4 mg/L of H2O2. The columns were run in a continuous downflow operation, with no provision for backwash, as the quality of the UF membrane permeate feed led to no observable accumulation of head loss over the period of operation. At times 0 month (virgin), after 3 months, and 6 months of aging, the capacity of GACs to remove 100 ng/L of geosmin and MIB was evaluated (Table 3). At these predetermined time intervals (ie, 0, 3, and 6 months), the aging process was stopped, and membrane permeate was spiked with 100 ng/L of geosmin and MIB, which is the highest detected value in Lake Ontario, Canada. The geosmin and MIB containing membrane permeate were filtered through the columns for equivalent of 1-week bed volume. Geosmin and MIB concentrations were measured along the depth of the column (ie, inlet; 25 cm, 50 cm, 75 cm, and 100 cm; and outlet).
Table 3

Range (including analytical method bias) of concentrations used for spiking periods, T = 0, 3, and 6 months, for geosmin and MIB.

METABOLITESSET-UPTIME 0 MONTHS (HIGH CONCENTRATION)TIME 3 AND 6 MONTHS
MIBPilot (Canada)100 n/L100 ng/L (Duration 1 week)
Laboratory (Australia)50 ng/LWeek 1 (low concentration): 15 ng/LWeek 2 (high concentration): 50 ng/L
GeosminPilot (Canada)100 ng/L100 ng/L (Duration 1 week)
Laboratory (Australia)50 ng/LWeek 1 (low concentration): 15 ng/LWeek 2 (high concentration): 50 ng/L

Laboratory-scale GAC column testing in Australia

Figure 4A shows the schematic representation of the column setup for the Australian trials (without advanced oxidation prior to GAC), and Figure 4B is a photograph of the columns in the laboratory at a WTP located in South Australia. Four laboratory-scale columns were set up and run at the Australian WTP, fed with water from the settled water ducts. The performance of two types of GAC for the removal of geosmin and MIB was verified using the laboratory-scale experiment over a period of 6 months. This setup provides the opportunity to conduct the test in duplicate. Column conditions and GAC details are presented in Tables 1 and 2, respectively. Spiking trials were conducted at 0, 3, and 6 months after commissioning to determine the removal of cyanobacterial metabolites. Two inlet concentrations of metabolites were used for the conducted trials. During the spiking trials, for 1–2 weeks, metabolites were dosed in continuously, and samples were collected from the influent and filtrate daily for analysis. The percent removal values and the mean removal values for each inlet concentration (errors associated: standard deviation) were calculated. Table 3 presents the target concentration for the spiking trials.
Figure 4

Laboratory setup at the Australian plant: (A) schematic representation of the columns and (B) general view of the functional columns.

Cyanobacterial metabolite materials and water quality analysis

Geosmin and MIB were purchased from commercial suppliers (Novachem Pty Ltd. and Ultrafine Chemicals) and dissolved in ultrapure water (Millipore Pty Ltd.) to prepare a stock solution. Aliquots from the stock solution were then dosed into waters at the required target concentrations. Samples for dissolved organic Carbon (DOC) and UV absorbance were filtered through 0.45 µm prerinsed (ultrapure water) membranes. DOC was measured using a Sievers 900 Total Organic Carbon Analyzer (GE Analytical Instruments). UV absorbance at 254 nm was measured through a 1 cm quartz cell using an Evolution 60 Spectrophotometer (Thermo Scientific). All analyses were conducted in triplicate for each sample. Bench-scale experiment samples for geosmin and MIB analyses were concentrated using a solid-phase micro extraction syringe fiber (Gerstel) and analyzed on a 7890A Gas Chromatograph System with 5975C VL Series Mass Selective Detector (Agilent Technologies) against quantified labeled internal standards (Ultrafine Chemicals). Full details of this method have been documented by Graham and Hayes.41 The reporting limits for MIB and geosmin were 4 and 2 ng/L, respectively. Significant difference between the removals of T&O compounds using GAC exposed to different aging processes was statistically assessed. Two methods were used to monitor the biological activity: (1) adenosine triphosphate (ATP) and (2) scanning electron microscopy (SEM). In Canada, total ATP (in nanogram/gram) is measured using a commercially available deposit and surface analysis (DSM™) test kit (Luminultra). In Australia, ATP was measured (in nanogram/gram) using a method outlined by McDowall.42 Samples of the filter media were taken from the top of each column prior to and immediately after the spiking events. For SEM analysis, samples of the filter media were taken before and after the 6-month laboratory- and pilot-scale trails. They were fixed for 1 hour using EM fixative (4% paraformaldehyde/1.25% glutaraldehyde in PBS, +4% sucrose, and pH 7.2), washed in buffer (Phosphate-buffered saline (PBS) and +4% sucrose), post-fixed with 2% osmium tetroxide in water for 30 minutes, and then dehydrated with increasing ethanol solutions (70%, 90%, and 100%). Subsequently, the samples underwent critical point drying and were mounted on a stub and coated with carbon ready for analysis on a Field Emission Scanning Electron Microscope (FESEM). Samples of the virgin filter media were also mounted and coated ready for analysis. Photographs were obtained using a Philips XL30 FESEM.

Results and Discussions

Impact of advanced UV–H2O2 oxidation and H2O2 residual quenching on GAC capacity to remove T&O compounds

AOP used in the studied Canadian WTP (Fig. 2) includes H2O2 dosage prior to UV oxidation to generate very strong OH• radical oxidant.43,44 The elementary reaction in the UV–H2O2 advanced oxidation system is as follows (Equation 1): where hv is the UV irradiation. In this plant, GAC contactors are used to remove the residual H2O2 post AOP from water prior to chlorination. Previous publications31,36 have demonstrated that for all types of GAC (Table 2) used in this study, the H2O2 quenching rate decreased significantly up to 25,000 bed volumes and then stabilized to a constant rate (±5 variation) for over 2 years of operation. These results are in accordance with the performance of GAC in 3 full-scale plants in North America and Europe to remove H2O2 for over 6 years without media replacement.31 During the operation of the Canadian plant, H2O2 is only dosed during the bloom season (September to November). Therefore, the AOP is only available during this time period as a strong oxidation barrier against T&O compounds in water. For the rest of the operational time, adsorption on GAC is the only treatment process for the removal of these compounds. The pilot study was used to study the impact of H2O2 quenching on GAC capacity to adsorb geosmin and MIB to ensure the efficiency of available treatment barriers at all times. For geosmin treatment, 25–50 cm of virgin GACs were sufficient for the removal of 100 ng/L to below detection limit, which is 2 ng/L (Fig. 5). However, after 3 months of quenching 4 mg/L of H2O2 with an EBCT of 4.1 minutes, the entire 128-cm column depth was required to remove >93% of the geosmin. No significant difference was observed between the geosmin removal capacity of columns with (Fig. 5) and without (data not shown) H2O2 quenching.
Figure 5

Geosmin removal using virgin carbon, and after 3 and 6 months of H2O2 quenching. Similar geosmin concentrations were measured in water samples from columns (at all depths) without H2O2 quenching (data not shown).

Note: *BDL, below detection limit.

All GAC types and ages, even virgin GAC, were less efficient for the removal of MIB compared to geosmin. Furthermore, after 3 months of pilot operation, MIB centration in column permeates reached >10 ng/L. However, similar to geosmin removal, the GAC capacities for MIB removal were not significantly affected by the H2O2 quenching, as similar removal values were observed with (Fig. 6) and without (data not shown) H2O2 quenching. Ndiongue et al.45 demonstrated that an increase in GAC depth or EBCT would significantly improve the removal of geosmin and MIB from water. Furthermore, other studies have also observed better (minimum 13%) geosmin removal compared to MIB removal by GAC.46,47
Figure 6

MIB removal using virgin carbon, and after 3 and 6 months of H2O2 quenching. Similar MIB concentrations were measured in water samples from columns (at all depths) without H2O2 quenching (data not shown).

All four types of GAC provided similar performance for the removal of geosmin with and without advanced oxidation (Fig. 5). Centaur and F300 provided the best MIB removal in both the absence and presence of H2O2 quenching aging process (Fig. 6). Independent of the GAC type, the top 25 cm of GAC was the most effective for the removal of geosmin (Fig. 5). In the meantime, the top 75 cm of GAC removed the greatest percentage of MIB (Fig. 6). While biofilm formation covers the adsorbent surface of carbon, the biological activity of microorganisms could lead to biodegradation of T&O compounds.48–51 SEM is a qualitative method that can be used to investigate the existence and composition of a biofilm on filter media. Although SEM does not allow the identification of individual organisms, it can be used to show the abundance and diversity of organisms within the biofilm. SEM analysis provides the opportunity for visual observation of GAC surface during AOPs and adsorption experiences (Fig. 7). SEM images from the Canadian pilot study for six virgin GACs and six GAC aged with membrane permeate and H2O2 after 33,000 bed volumes are shown in Figures 7A–7H. These SEMs demonstrate that a significant biomass has accumulated during the trials. The observation of biofilm formation on GAC surface after aging was also reported in the study by Yu et al.34
Figure 7

SEM data: Centaur (A) virgin, and (B) aged with NOM at 45,000 bed volumes; F300 (C) virgin, and (D) aged with NOM at 33,000 bed volumes; HD3000 (E) virgin, and (F) aged with NOM at 33,000 bed volumes; TN5 (G) virgin, and (H) aged with NOM at 33,000 bed volumes (Figs. 7A to 7H scale is 5 µm); AND GA1000N (AWQC) particle size 0.5–0.7 mm diameter (I) virgin (Fig. 7.I. 1 scale is 50 µm and Fig. 7.I.2 scale is 10 µm), and (J) 6 months after commissioning (Figs. 7.j.1 and 7.j.2 are taken from different angels at 5 µm scale).

The biofilms are composed of a variety of organisms, including bacteria, protozoa, fungi, and diatoms, and it is held together by extracellular polymeric material. It is not possible to identify individual microorganisms with analytical methods used in this study, and so no differences can be established between the different GAC types. However, it is clear that abundance and diversity of microorganisms exist within the thriving biofilms. The level of biological activity of the established biofilm would determine the potential for the biodegradation of T&O compounds. ATP is present in all active microorganisms; therefore, ATP concentrations can be used as a measure of biological activity and an indicator for the presence of an active biofilm on filter media. Samples of the filter media were taken prior to the spiking trials and directly after collecting the final effluent from the spiking trial to look at the impact of the spiked settled water on the biological activity of the filter media. GAC appeared to have negligible ATP activity before and after the spiking trials.

GAC capacity to remove T&O compounds in the absence of advanced oxidation barriers

To compare the geosmin and MIB removal with GAC depth with and without advanced oxidation, the results from the Canadian study were compared to the laboratory-based column study conducted in Australia. H2O2 removal on GAC was not the focus of the study conducted in Australia. In all Australian assays, geosmin was removed to below detection limit (data not shown). Figure 8 demonstrates that for MIB removal, the F300 GAC was performed as well as the GA1000N over the trial period. An application of analysis of variance (P > 0.1) to the GAC data showed that there was no significant decrease in the removal by the GAC over the trial period. As for the percent removals for the two inlet concentrations (low and high), similar results were obtained for GAC aged for 3 and 6 months.
Figure 8

MIB removal by two types of GAC during the Australian experiment.

Note: *BDL, below detection limit.

The results for the duplicate columns over 6 months demonstrate good (<7% error) reproducibility of the column data over the trial. GAC was very effective for the removal of MIB and geosmin over the trial period with an average of 98% and 100% removal, respectively. This result supports the previous work by Ho,48 who investigated the removal of MIB and geosmin by GAC at the laboratory and pilot scales. Such high removals had been shown previously to be attributable to physical adsorption only50,51; however, as the removal values were high throughout the test period, it was not possible to differentiate between physical adsorption and biological degradation in this study. Figures 7I and 7J show SEM images of the initial GAC media as new, prior to the column trials and after 6 months in contact with settled water from the Australian WTP. However, similar to the Canadian pilot study, no significant biological activity was recorded. This result was unexpected, based on previous publications.52 GAC surface is known to promote significant biofilm growth within 4–6 weeks of filter commissioning.53 The low value of ATP on the GAC suggested that the adsorbent interfered in some way with the ATP analysis. These results suggest that no biological removal had occurred. This study has focused on the fate of dissolved geosmin and MIB during advanced oxidation and adsorption and/or biodegradation by GAC. The multibarrier treatment systems that are in use in the studied conditions (Fig. 2) prior to GAC contactors reduce significantly the risk of breakthrough of intact cells and intracellular T&O compounds. However, plants with conventional treatment barriers, which are coagulation–clarification and filtration, are vulnerable to breakthrough of intact cells and intracellular and dissolved compounds.4,14,28,54–56 The removal of cell-bound compound within intact cells is the preferred situation for conventional treatment plants, while plants equipped with advanced oxidation and/or adsorption barriers would be able to handle the presence of dissolved compounds. However, recent publications14,57 have demonstrated that breakthrough of cells and their intracellular compounds, even at plants with low risk of cyanobacterial presence at their source, is a major challenge. Also, lysis of accumulated cells within sludge bed or filter media20,57,58 and release of geosmin and MIB prior to chlorination in the absence of strong oxidant agents (eg, O3) would lead to breakthrough of these compounds into the potable water. Hence, the intra/extracellular ratio of geosmin and MIB is a key factor for their successful removal and optimization of treatment processes.25 Several factors, including bloom age, producers present, water quality conditions and available nutrients, and geographical location, could influence the ratio of intra/extracellular compounds.19,21–23 Table 4 provides a useful summary of existing knowledge about the removal of cyanobacterial T&O compounds by conventional and advanced treatment barriers. However, this ratio and the factor that would influence its variations and the impact of these variations on conventional and advanced full-scale treatment barriers require further investigation.
Table 4

Treatment processes for the removal of cyanobacterial cells and cell-bound T&O compounds.1,4,10,20,21,23,28–31,46–50,56,57,59,60

TREATMENT PROCESSTREATMENT EFFICIENCY
Oxidation processesThe efficiency of pre-oxidation depends on cell number, species present, type of T&O compounds, compounds concentration, oxidant type and dose, and contact time. Pre-oxidation induce cell membrane damage and/or lysis and consequent increase in dissolved taste and odor compound levels and disinfection by products formation. If applied under controlled situation it might be efficient; pre-oxidation of cells will prevent process disturbances in drinking water treatment plants due to presence of cyanobacteria cells. The natural organic matters in water influence the dose of oxidant agent.
OzonationOzonation is effective for removal of all cells and both geosmin and MIB.
ChlorinationChloraminationChlorine dioxidePotassium permanganateHydrogen peroxideNot effective for oxidation of geosmin and MIB. Direct oxidation of cyanobacterial cells would cause release of cell-bound T&O compounds which needed to be removed.
UV RadiationInduce cell membrane damage and T&O compounds release. However oxidation occurs at impractically high doses or in the presence of a catalyst.
Advanced oxidation processes (AOP)UV-H2O2 or UV-O3 advanced oxidation processes which lead to generation of OH are very effective for removal of these T&O compounds. However, processes by products, for example H2O2 residual, have to be removed from water.
Adsorption – Powder Activated Carbon (PAC)Has no documented impact on cell viability or their removal. Efficient for removal of dissolved T&O compounds. The type of PAC, dose of PAC, water quality (including pH and NOM), type of present compounds, and intra/extra cellular ratio plays an important role in their removal by PAC.
Adsorption – Granular Activated Carbon (GAC)Physical removal of cyanobacteria cells during filtration and simultaneous removal of cell-bound compounds within intact cells. Very effective for adsorption of dissolved compounds based on the type of GAC. However, GAC adsorption of release compounds displays a limited lifetime depending on the compound and the water quality.
Biological filtrationOnce the biofilm is established and the process is functioning at the optimum, it can be very effective for the removal of intact cells and T&O compounds. However, factors affecting the removal such as biofilm mass and composition, acclimation periods, temperature and water quality cannot be easily controlled.

Conclusion

The results of this study demonstrate that H2O2 quenching for the operational period of 6 months has no significant impact on GAC capacity to remove geosmin and MIB from water. Furthermore, type of T&O compounds, concentration of compounds, ratio of intra/extracellular compound, producer species present and duration of bloom season, GAC type, EBCT, and other operational practices are the factors that influence GAC capacity to remove the studied T&O compounds. During the trial period, all filtration media developed significant biomass. However, there was no evidence of the onset of biological degradation of the cyanobacterial metabolites for any of the GAC types. Measurement of biofilm activity was a limiting factor within this study. Formation and maintenance of an active biofilm is a challenge during the operation of biologically active water treatment processes. The development of rapid methods to monitor the biofilm formation and level of activity would provide the utilities with the essential operational information. The impact of biofilm formation on GAC and its capacity for the removal of H2O2 and T&O compounds require further investigation. These results demonstrate the benefits of multibarrier treatment approaches for the removal of emerging cyanobacterial harmful metabolites. However, further investigation would be required to investigate the efficiency of the studied treatment processes for the removal of these metabolites within the context of climate change scenarios, significantly higher cell numbers, frequent bloom events, higher metabolites concentrations, and varying intra/extracellular ratio.
  27 in total

1.  Detection and estimation of potentially toxic cyanobacteria in raw water at the drinking water treatment plant by in vivo fluorescence method.

Authors:  Jakub Gregor; Blahoslav Marsálek; Helena Sípková
Journal:  Water Res       Date:  2006-10-02       Impact factor: 11.236

Review 2.  Biochemical and ecological control of geosmin and 2-methylisoborneol in source waters.

Authors:  Friedrich Jüttner; Susan B Watson
Journal:  Appl Environ Microbiol       Date:  2007-03-30       Impact factor: 4.792

Review 3.  Controlling harmful cyanobacterial blooms in a world experiencing anthropogenic and climatic-induced change.

Authors:  Hans W Paerl; Nathan S Hall; Elizabeth S Calandrino
Journal:  Sci Total Environ       Date:  2011-02-23       Impact factor: 7.963

4.  Vulnerability of Quebec drinking-water treatment plants to cyanotoxins in a climate change context.

Authors:  Annie Carrière; Michèle Prévost; Arash Zamyadi; Pierre Chevalier; Benoit Barbeau
Journal:  J Water Health       Date:  2009-12-04       Impact factor: 1.744

5.  Seasonal occurrence and degradation of 2-methylisoborneol in water supply reservoirs.

Authors:  Paul Westerhoff; M Rodriguez-Hernandez; Larry Baker; Milton Sommerfeld
Journal:  Water Res       Date:  2005-12       Impact factor: 11.236

6.  The effect of UV/H2O2 treatment on biofilm formation potential.

Authors:  D H Metz; K Reynolds; M Meyer; D D Dionysiou
Journal:  Water Res       Date:  2010-09-17       Impact factor: 11.236

Review 7.  Treatment of taste and odor causing compounds 2-methyl isoborneol and geosmin in drinking water: a critical review.

Authors:  Rangesh Srinivasan; George A Sorial
Journal:  J Environ Sci (China)       Date:  2011       Impact factor: 5.565

8.  Influence of surface modification on catalytic activity of activated carbon toward decomposition of hydrogen peroxide and 2-chlorophenol.

Authors:  Hsu-Hui Huang; Ming-Chun Lu; Jong-Nan Chen; Cheng-Te Lee
Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng       Date:  2003-07       Impact factor: 2.269

9.  Catalytic decomposition of hydrogen peroxide and 4-chlorophenol in the presence of modified activated carbons.

Authors:  Hsu-Hui Huang; Ming-Chun Lu; Jong-Nan Chen; Cheng-Te Lee
Journal:  Chemosphere       Date:  2003-06       Impact factor: 7.086

10.  Species-dependence of cyanobacteria removal efficiency by different drinking water treatment processes.

Authors:  Arash Zamyadi; Sarah Dorner; Sébastien Sauvé; Donald Ellis; Anouka Bolduc; Christian Bastien; Michèle Prévost
Journal:  Water Res       Date:  2013-02-28       Impact factor: 11.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.