Literature DB >> 26461487

Redefining the Acetabular Component Safe Zone for Posterior Approach Total Hip Arthroplasty.

Jonathan R Danoff1, Jacob T Bobman1, Gregory Cunn1, Taylor Murtaugh1, Prakash Gorroochurn1, Jeffrey A Geller1, William Macaulay1.   

Abstract

BACKGROUND: Acetabular component orientation influences joint stability in total hip arthroplasty (THA). The purpose of this study was to evaluate the effect of cup orientation and other variables on hip dislocation risk and to define a posterior approach specific safe zone.
METHODS: A cohort of 1289 posterior approach primary THA cases was prospectively followed and component position measured radiographically.
RESULTS: Cup malposition, with respect to the Lewinnek safe zone, was an independent risk factor for dislocation (OR1.88). Modifying the anteversion safe zone limits to 10-25° strongly predicted increased dislocation risk (OR2.69). No dislocations occurred within a zone defined by a circle centered at 41.4° abduction and 17.1° anteversion, radius 4.3°.
CONCLUSION: Utilizing a posterior approach specific safe zone of 10-25° anteversion and 30-50° abduction may minimize THA dislocations. LEVEL OF EVIDENCE: Level III.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  acetabulum; cup orientation; dislocation; safe zone; total hip arthroplasty

Mesh:

Year:  2015        PMID: 26461487     DOI: 10.1016/j.arth.2015.09.010

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  23 in total

1.  Can an Augmented Reality Headset Improve Accuracy of Acetabular Cup Orientation in Simulated THA? A Randomized Trial.

Authors:  Kartik Logishetty; Luke Western; Ruairidh Morgan; Farhad Iranpour; Justin P Cobb; Edouard Auvinet
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

Review 2.  [Hip dislocation after revision arthroplasty : Risk assessment and treatment strategies].

Authors:  P M Prodinger; J Schauwecker; H Mühlhofer; N Harrasser; F Pohlig; C Suren; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

3.  Plan in 2-D, execute in 3-D: an augmented reality solution for cup placement in total hip arthroplasty.

Authors:  Javad Fotouhi; Clayton P Alexander; Mathias Unberath; Giacomo Taylor; Sing Chun Lee; Bernhard Fuerst; Alex Johnson; Greg Osgood; Russell H Taylor; Harpal Khanuja; Mehran Armand; Nassir Navab
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-04

4.  The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.

Authors:  William S Murphy; Ho Hyun Yun; Brett Hayden; Jens H Kowal; Stephen B Murphy
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

5.  Transfusion Rates in Total Hip Arthroplasty Are lower in Patients with Direct Anterior Approach.

Authors:  George A Komnos; Jorge Manrique; Carol Foltz; Mitchell R Klement; Camilo Restrepo; Javad Parvizi
Journal:  Arch Bone Jt Surg       Date:  2021-11

Review 6.  Acetabular cup position and risk of dislocation in primary total hip arthroplasty.

Authors:  Kurt G Seagrave; Anders Troelsen; Henrik Malchau; Henrik Husted; Kirill Gromov
Journal:  Acta Orthop       Date:  2016-11-23       Impact factor: 3.717

7.  Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles.

Authors:  T E Snijders; T P C Schlösser; S M van Gaalen; R M Castelein; H Weinans; A de Gast
Journal:  JB JS Open Access       Date:  2018-07-12

8.  A Geometric Model to Determine Patient-Specific Cup Anteversion Based on Pelvic Motion in Total Hip Arthroplasty.

Authors:  E Grant Sutter; Samuel S Wellman; Michael P Bolognesi; Thorsten M Seyler
Journal:  Adv Orthop       Date:  2019-05-02

9.  A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty.

Authors:  Ryo Mitsutake; Hiromasa Tanino; Yasuhiro Nishida; Masaru Higa; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2020-02-19       Impact factor: 2.362

10.  An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position.

Authors:  Tomonori Tetsunaga; Kazuki Yamada; Tomoko Tetsunaga; Tomoaki Sanki; Yoshi Kawamura; Toshifumi Ozaki
Journal:  J Orthop Surg Res       Date:  2020-04-15       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.