Literature DB >> 26459224

Quasi-non-linear deformation modeling of a human liver based on artificial and experimental data.

Firat Dogan1, M Serdar Celebi2.   

Abstract

BACKGROUND: Researchers working on error-prevention theories have shown that the use of replica models within simulation systems has improved operating skills, resulting in better patient outcomes.
METHODS: This study aims to provide material test data specifically for a human liver to validate the accuracy of viscoelastic soft tissue models. This allows the validation of virtual surgery simulators by comparison with physical test data obtained from material tests on a viscoelastic silicone gel pad.
RESULTS: The results proved that stress behavior and relaxation curves of Aquaflex® experiment and FEM simulation are close if average liver response and respective material parameters and model are used.
CONCLUSIONS: The precise representation of manipulated tissues used in virtual surgery trainers involves the accurate characterization of mechanical properties of the tissue. Consequently, successful implementations of these mechanical properties in a mathematical model of the deforming organ are of major importance.
Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  deformable models; indentation experiment; material coefficients; nonlinear simulations; real-time simulation; soft tissue; viscoelasticity

Mesh:

Substances:

Year:  2015        PMID: 26459224     DOI: 10.1002/rcs.1704

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  5 in total

1.  Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh Samples Under Varying Scan Parameters.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu; Kamal M F Itani
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06       Impact factor: 2.725

2.  Impact of High-Intensity Ultrasound on Strength of Surgical Mesh When Treating Biofilm Infections.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu; Kamal M F Itani
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-14       Impact factor: 2.725

3.  Scan Parameter Optimization for Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-18       Impact factor: 2.725

4.  Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh Samples Under Varying Pulse Durations.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu; Kamal M F Itani
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-06-22       Impact factor: 2.725

5.  On the flexible needle insertion into the human liver.

Authors:  Veturia Chiroiu; Nicoleta Nedelcu; Doina Pisla; Ligia Munteanu; Cristian Rugină
Journal:  Sci Rep       Date:  2021-05-13       Impact factor: 4.379

  5 in total