Literature DB >> 26454455

Ultra-sensitive immunosensor for detection of hepatitis B surface antigen using multi-functionalized gold nanoparticles.

M Shourian1, H Ghourchian2, M Boutorabi3.   

Abstract

The signal amplification for analytical purposes has considerable potential in detecting trace levels of analytes for clinical, security or environmental applications. In the present report a strategy based on a sandwich type immunoassay system was designed for the detection of hepatitis B surface antigen which exploits the specific affinity interaction between streptavidin and biotin recognition systems. The method involves the specific coupling of multi-functionalized gold nanoparticles (bearing biotin and luminol molecules) to the streptavidin modified by secondary antibody. The chemiluminescent signal is produced by the gold nanoparticles in the presence of HAuCl4 as catalyst and hydrogen peroxide as oxidant. The immunosensor was able to detect hepatitis B surface antigen in the linear concentration range from 1.7 to 1920 pg mL(-1) and the detection limit of 0.358 pg mL(-1), at signal/noise = 3.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biotin; Chemiluminescence; Gold nanoparticles; Hepatitis B surface antigen; Immunoassay; Streptavidin

Mesh:

Substances:

Year:  2015        PMID: 26454455     DOI: 10.1016/j.aca.2015.07.013

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  7 in total

Review 1.  Diagnosis of hepatitis via nanomaterial-based electrochemical, optical or piezoelectrical biosensors: a review on recent advancements.

Authors:  Soodabeh Hassanpour; Behzad Baradaran; Miguel de la Guardia; Amir Baghbanzadeh; Jafar Mosafer; Maryam Hejazi; Ahad Mokhtarzadeh; Mohammad Hasanzadeh
Journal:  Mikrochim Acta       Date:  2018-12-01       Impact factor: 5.833

2.  Conjugation of VEGFR1/R2-targeting peptide with gold nanoparticles to enhance antiangiogenic and antitumoral activity.

Authors:  Pegah Zanjanchi; S Mohsen Asghari; Hassan Mohabatkar; Mostafa Shourian; Mehdi Shafiee Ardestani
Journal:  J Nanobiotechnology       Date:  2022-01-04       Impact factor: 10.435

3.  Naked-Eye Detection of Hepatitis B Surface Antigen Using Gold Nanoparticles Aggregation and Catalase-Functionalized Polystyrene Nanospheres.

Authors:  Rubing Chen; Yongqin Hu; Meizhu Chen; Jia An; Ying Lyu; Yufei Liu; Dongling Li
Journal:  ACS Omega       Date:  2021-03-30

4.  Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor.

Authors:  Balal Khalilzadeh; Nasrin Shadjou; Hadi Afsharan; Morteza Eskandani; Hojjatollah Nozad Charoudeh; Mohammad-Reza Rashidi
Journal:  Bioimpacts       Date:  2016-09-30

Review 5.  Applicability of Metal Nanoparticles in the Detection and Monitoring of Hepatitis B Virus Infection.

Authors:  Maxim Shevtsov; Lili Zhao; Ulrike Protzer; Maarten A A van de Klundert
Journal:  Viruses       Date:  2017-07-21       Impact factor: 5.048

Review 6.  Nanomaterial application in bio/sensors for the detection of infectious diseases.

Authors:  Elham Sheikhzadeh; Valerio Beni; Mohammed Zourob
Journal:  Talanta       Date:  2020-12-17       Impact factor: 6.057

Review 7.  The Applications of Gold Nanoparticle-Initialed Chemiluminescence in Biomedical Detection.

Authors:  Zezhong Liu; Furong Zhao; Shandian Gao; Junjun Shao; Huiyun Chang
Journal:  Nanoscale Res Lett       Date:  2016-10-18       Impact factor: 4.703

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.