Literature DB >> 26454269

EYE LENS DOSIMETRY FOR FLUOROSCOPICALLY GUIDED CLINICAL PROCEDURES: PRACTICAL APPROACHES TO PROTECTION AND DOSE MONITORING.

Colin J Martin1.   

Abstract

Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Mesh:

Year:  2015        PMID: 26454269     DOI: 10.1093/rpd/ncv431

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

Review 1.  What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?

Authors:  Koichi Chida
Journal:  Radiol Phys Technol       Date:  2022-05-24

Review 2.  Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures.

Authors:  Masaaki Akahane; Naoki Yoshioka; Shigeru Kiryu
Journal:  Interv Radiol (Higashimatsuyama)       Date:  2022-07-01

3.  Managing occupational doses with smartphones in interventional radiology.

Authors:  Roberto M Sánchez; Daniel Fernández; Eliseo Vañó; José M Fernández
Journal:  Med Phys       Date:  2021-08-17       Impact factor: 4.506

4.  On the scenario of passive dosimeters in personnel monitoring: Relevance to diagnostic radiology and fluoroscopy-based interventional cardiology.

Authors:  A S Pradhan; J I Lee; J L Kim
Journal:  J Med Phys       Date:  2016 Apr-Jun

5.  Radiation Protection in Interventional Radiology/Cardiology-Is State-of-the-Art Equipment Used?

Authors:  Christiane Behr-Meenen; Heiner von Boetticher; Jan Felix Kersten; Albert Nienhaus
Journal:  Int J Environ Res Public Health       Date:  2021-12-13       Impact factor: 3.390

  5 in total