Direct determination of chromium in infant formulas employing high-resolution continuum source electrothermal atomic absorption spectrometry and solid sample analysis.

Arlene S Silva1, Geovani C Brandao1, Geraldo D Matos2, Sergio L C Ferreira3.   

Abstract

The present work proposed an analytical method for the direct determination of chromium in infant formulas employing the high-resolution continuum source electrothermal atomic absorption spectrometry combined with the solid sample analysis (SS-HR-CS ET AAS). Sample masses up to 2.0mg were directly weighted on a solid sampling platform and introduced into the graphite tube. In order to minimize the formation of carbonaceous residues and to improve the contact of the modifier solution with the solid sample, a volume of 10 µL of a solution containing 6% (v/v) H2O2, 20% (v/v) ethanol and 1% (v/v) HNO3 was added. The pyrolysis and atomization temperatures established were 1600 and 2400 °C, respectively, using magnesium as chemical modifier. The calibration technique was evaluated by comparing the slopes of calibration curves established using aqueous and solid standards. This test revealed that chromium can be determined employing the external calibration technique using aqueous standards. Under these conditions, the method developed allows the direct determination of chromium with limit of quantification of 11.5 ng g(-1), precision expressed as relative standard deviation (RSD) in the range of 4.0-17.9% (n=3) and a characteristic mass of 1.2 pg of chromium. The accuracy was confirmed by analysis of a certified reference material of tomato leaves furnished by National Institute of Standards and Technology. The method proposed was applied for the determination of chromium in five different infant formula samples. The chromium content found varied in the range of 33.9-58.1 ng g(-1) (n=3). These samples were also analyzed employing ICP-MS. A statistical test demonstrated that there is no significant difference between the results found by two methods. The chromium concentrations achieved are lower than the maximum limit permissible for chromium in foods by Brazilian Legislation.
Copyright © 2015. Published by Elsevier B.V.

Entities:  

Keywords:  Chromium determination; Direct solid sampling; High-resolution continuum source electrothermal atomic absorption spectrometry; Infant formulas

Mesh:

Substances:

Year:  2015        PMID: 26452789     DOI: 10.1016/j.talanta.2015.05.046

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A nanocomposite probe consisting of carbon quantum dots and phosphotungstic acid for fluorometric determination of chromate(VI) with improved selectivity.

Authors:  Yushan Liu; Zhijun Chen; Wei Li; Chunhui Ma; Peng Wu; Xueyun Wu; Shujun Li; Shouxin Liu
Journal:  Mikrochim Acta       Date:  2018-09-20       Impact factor: 5.833

2.  Nitrogen, phosphorus and sulfur tri-doped carbon dots are specific and sensitive fluorescent probes for determination of chromium(VI) in water samples and in living cells.

Authors:  Shan Huang; Erli Yang; Jiandong Yao; Xu Chu; Yi Liu; Qi Xiao
Journal:  Mikrochim Acta       Date:  2019-11-27       Impact factor: 5.833

3.  Synthesis of intrinsic dual-emission type N,S-doped carbon dots for ratiometric fluorescence detection of Cr (VI) and application in cellular imaging.

Authors:  Xiping Mei; Dongxiu Wang; Songbai Wang; Junfen Li; Chuan Dong
Journal:  Anal Bioanal Chem       Date:  2022-08-18       Impact factor: 4.478

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.