Literature DB >> 26450831

Identification of overlengthening after replacement of the radial head with a bipolar prosthesis.

K Wegmann1,2, J Lamsfuss3, C Ries3,4, W F Neiss5, J Franklin6, L P Müller3,4, K J Burkhart7.   

Abstract

INTRODUCTION: Overlengthening of the radial column leads to insufficient functionality and increased capitellar wear. Methods to detect or prevent overlengthening have been described for monopolar prostheses. The aim of this study was to evaluate whether one such method described by Athwal et al. is also applicable for a bipolar prosthesis.
MATERIALS AND METHODS: The radial heads of six fresh frozen upper extremities were resected. A bipolar radial head prosthesis was implanted in each, and the effects of sequential overlengthening on the alignment of the radiocapitellar and ulnohumeral joint line were recorded by fluoroscopic images. Digital image analysis and estimation of overlengthening followed according to the method described by Athwal et al.
RESULTS: Statistical analysis of the estimated and actual differences between the native state and bipolar replacement of the radial head with stepwise overlengthening of 1.5, 3, 4.5, and 6 mm showed a specificity of 86 % but consistently underestimated the amount of overlengthening with a sensitivity of only 61 %. DISCUSSION: The method described by Athwal et al. for the identification of overlengthening by a monopolar prosthesis was not found to be reliable for ruling out or quantifying overlengthening of the tested bipolar prosthesis. However, the use of the method to detect (rule in) overlengthening may be acceptable in certain circumstances. A reliable method for postoperative quantification of overlengthening by bipolar prostheses has still to be found.

Entities:  

Keywords:  Bipolar prosthesis; Forearm rotation; Overlengthening; Prosthetic replacement; Radial head; Ulnohumeral joint

Mesh:

Year:  2015        PMID: 26450831     DOI: 10.1007/s00402-015-2333-4

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  [Radial head arthropolasty in unreconstructable comminuted fractures of the radial head: Long-term results and factors influencing the outcome].

Authors:  Ulf-Wilhelm Bökeler; Felix Kraft; Robert Schappacher; Verena Weisenberger; Anna Herlan; Ulrich C Liener
Journal:  Unfallchirurg       Date:  2022-01-25       Impact factor: 1.000

2.  Fracture Pattern Influences Radial Head Replacement Size Determination Among Experienced Elbow Surgeons.

Authors:  Davide Cucchi; Francesco Luceri; Andrea Celli; Alessandra Menon; Raul Barco; Kilian Wegmann; Pietro Randelli; Denise Eygendaal; Paolo Arrigoni
Journal:  Indian J Orthop       Date:  2020-03-18       Impact factor: 1.251

Review 3.  [The proximal radioulnar joint in consideration of the distal radioulnar joint].

Authors:  J Oppermann; K J Burkhart; S Löw; L P Müller
Journal:  Orthopade       Date:  2018-08       Impact factor: 1.087

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.