Literature DB >> 2644808

Flow cytometric indirect immunofluorescence assay with high sensitivity and specificity for detection of antibodies to human immunodeficiency virus (HIV).

J M Sligh1, S T Roodman, C C Tsai.   

Abstract

A flow cytometric immunofluorescence assay (FIFA) was developed to detect antibodies to human immunodeficiency virus (HIV) using live cell indirect immunofluorescence and analysis by flow cytometry. A panel of 107 sera, previously tested for anti-HIV antibody with the Abbott Enzyme-Linked Immunosorbent Assay test and Western blot (WB), was rescreened by FIFA. Antibodies were tested on HIV-infected and uninfected H9 cells in the FIFA. Although ELISA results indicated seven false positive results by comparison with the WB, 46 of 46 FIFA positive results tested WB positive and 61 of 61 FIFA negative results were WB negative. The results of FIFA showed 100% sensitivity and 100% specificity compared with WB. This rapid, quantitative, relatively easy assay makes FIFA an alternate confirmatory test for the presence of HIV antibodies.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2644808     DOI: 10.1093/ajcp/91.2.210

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  6 in total

Review 1.  Uses of flow cytometry in virology.

Authors:  J J McSharry
Journal:  Clin Microbiol Rev       Date:  1994-10       Impact factor: 26.132

Review 2.  Applications of flow cytometry to clinical microbiology.

Authors:  A Alvarez-Barrientos; J Arroyo; R Cantón; C Nombela; M Sánchez-Pérez
Journal:  Clin Microbiol Rev       Date:  2000-04       Impact factor: 26.132

3.  Antibody to native human immunodeficiency virus type 1 envelope glycoproteins induced by IIIB and MN recombinant gp120 vaccines. The NIAID AIDS Vaccine Evaluation Group.

Authors:  G J Gorse; G B Patel; F K Newman; R B Belshe; P W Berman; T J Gregory; T J Matthews
Journal:  Clin Diagn Lab Immunol       Date:  1996-07

4.  Advantages of a human immunodeficiency virus type 1 (HIV-1) persistently infected HeLa T4+ cell line for HIV-1 indirect immunofluorescence serology.

Authors:  B Forghani; J W Hurst; C S Chan
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

5.  Detection of binding antibodies to native and recombinant human immunodeficiency virus type 1 envelope glycoproteins following recombinant gp160 immunization measured by flow cytometry and enzyme immunoassays. The AIDS Vaccine Clinical Trials Network.

Authors:  G J Gorse; S E Frey; F K Newman; R B Belshe
Journal:  J Clin Microbiol       Date:  1992-10       Impact factor: 5.948

6.  Flow cytometric immunofluorescence assay for detection of antibodies to human immunodeficiency virus type 1 using insoluble precursor forms of recombinant polyproteins as carriers and antigens.

Authors:  Y W Hu; P Birch; E Balaskas; A Zeibdawi; V Scalia; S A Thériault-Valin; P Gill; M T Aye
Journal:  J Clin Microbiol       Date:  1996-06       Impact factor: 5.948

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.