Literature DB >> 26447725

Different Intraorbital Implant Situations and Ocular Prosthetic Rehabilitation.

Himanshi Aggarwal1, Pradeep Kumar1, Prashanti Eachempati2, Habib A Alvi1.   

Abstract

Enucleation is the removal of the entire globe of the eye and a portion of the optic nerve, while evisceration involves the removal of the contents of the globe leaving the sclera, extraocular muscles, and optic nerve. Following enucleation or evisceration, intraorbital implants are routinely placed to enhance the prosthetic outcome in addition to restoring the lost orbital volume. Current practice employs intraorbital implants made of nonporous silicone, hydroxyapatite, or porous polyethylene. Intraorbital implant selection and placement, being a highly demanding procedure in terms of knowledge, skill, and expertise, may be associated with a multiplicity of technical and surgical errors. Complications are usually minimal with these implants, but they do occur. The literature reveals many articles related to intraorbital implants, their benefits, and complications; however, the literature regarding the effect of various intraorbital implant situations on the subsequent prosthetic rehabilitation is markedly scarce. Moreover, the need for interdisciplinary surgical and prosthetic interventions required for successful rehabilitation in cases of compromised implant situations has been underemphasized. Hence, this review aimed to evaluate the effect of different intraorbital implant situations on ocular rehabilitation and the required interdisciplinary surgical and prosthetic treatment approach for rehabilitation of enucleated/eviscerated sockets with compromised implant situations, to provide a critical appraisal, and to present a simplified management strategy.
© 2015 by the American College of Prosthodontists.

Entities:  

Keywords:  Enucleation; evisceration; intraorbital implant; ocular prosthesis

Mesh:

Substances:

Year:  2015        PMID: 26447725     DOI: 10.1111/jopr.12369

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  2 in total

1.  Study of conjunctival flora in anophthalmic patients: influence on the comfort of the socket.

Authors:  Alvaro Toribio; Teresa Marrodán; Isabel Fernández-Natal; Honorina Martínez-Blanco; Leandro Rodríguez-Aparicio; Miguel Á Ferrero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-06-10       Impact factor: 3.117

2.  Rehabilitation of an ocular defect with intraorbital implant and custom-made prosthesis using digital photography and gridded spectacle.

Authors:  Dolanchanpa Dasgupta; Kaustubh Das; Rajwinder Singh
Journal:  J Indian Prosthodont Soc       Date:  2019 Jul-Sep
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.