Literature DB >> 26444336

Graphitic carbon nitrides modified hollow fiber solid phase microextraction for extraction and determination of uric acid in urine and serum coupled with gas chromatography-mass spectrometry.

Ying-pei Sun1, Juan Chen2, Huan-yang Qi3, Yan-ping Shi4.   

Abstract

An elevated uric acid (UA) in urine or serum can affect renal function and blood pressure, which is an indicator of gout, cardiovascular and renal diseases, hypertension, etc. In this work, a new type of mixed matrix membrane (MMM), based on graphitic carbon nitrides (g-CNs) and hollow fiber (HF), was prepared and combined with solid phase microextraction (SPME) mode to determine UA in urine and serum followed by gas chromatography-mass spectrometry (GC/MS). The porous g-CNs were dispersed in ammonia, and then the exfoliated g-CNs nanosheets were held in the pores of HF by capillary forces and sonification. The prepared g-CNs modified HF (g-CNs-HF) was immersed in biofluid directly to extract UA with SPME mode and the solvent-free mode is convenient for further derivatization and analysis. To achieve the highest extraction efficiency (EF), main extraction and derivatization parameters, such as g-CNs-HF immobilizing time, sonification power and time of extraction, derivatization and desorption time, were optimized. Under the optimum extraction conditions, a favorable linearity of UA was obtained in the range 0.1-200μgmL(-1) with correlation coefficients higher than 0.9990, and the average recoveries at three spiked levels of UA in urine and serum ranged from 80.7% to 121.6%, from 84.7% to 101.1%, respectively. The obtained results demonstrated the developed g-CNs-HF-SPME is a simple, rapid, cost-effective, solvent-free method for the analysis of UA in biofluid.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Gas chromatography-mass spectrometry (GC/MS); Graphitic carbon nitrides (g-CNs); Hollow fiber (HF); Solid phase microextraction (SPME); Uric acid (UA)

Mesh:

Substances:

Year:  2015        PMID: 26444336     DOI: 10.1016/j.jchromb.2015.09.025

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  2 in total

1.  Silver Nanoparticle-Functionalised Nitrogen-Doped Carbon Quantum Dots for the Highly Efficient Determination of Uric Acid.

Authors:  Qianchun Zhang; Shuxin Du; Fengling Tian; Xixi Long; Siqi Xie; Shan Tang; Linchun Bao
Journal:  Molecules       Date:  2022-07-19       Impact factor: 4.927

2.  CVD graphene as an electrochemical sensing platform for simultaneous detection of biomolecules.

Authors:  Xiaodan Wang; Delan Gao; Mingji Li; Hongji Li; Cuiping Li; Xiaoguo Wu; Baohe Yang
Journal:  Sci Rep       Date:  2017-08-01       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.