Marko A Popovic1,2, Nicholas Carnevale3, Balazs Rozsa4,5, Dejan Zecevic1,6. 1. Department of Cellular and Molecular Physiology, Yale University School of Medicine, New Haven, Connecticut 06510, USA. 2. Institute for Multidisciplinary Research, Belgrade University, Belgrade 11030, Serbia. 3. Department of Neurobiology, Yale University School of Medicine, New Haven, Connecticut 06510, USA. 4. Institute of Experimental Medicine of the Hungarian Academy of Sciences, Budapest H-1083, Hungary. 5. The Faculty of Information Technology, Pázmány Péter University, Budapest H-1083, Hungary. 6. Kavli Institute for Neuroscience, Yale University School of Medicine, New Haven, Connecticut 06510, USA.
Abstract
Thousands of dendritic spines on individual neurons process information and mediate plasticity by generating electrical input signals using a sophisticated assembly of transmitter receptors and voltage-sensitive ion channel molecules. Our understanding, however, of the electrical behaviour of spines is limited because it has not been possible to record input signals from these structures with adequate sensitivity and spatiotemporal resolution. Current interpretation of indirect data and speculations based on theoretical considerations are inconclusive. Here we use an electrochromic voltage-sensitive dye which acts as a transmembrane optical voltmeter with a linear scale to directly monitor electrical signals from individual spines on thin basal dendrites. The results show that synapses on these spines are not electrically isolated by the spine neck to a significant extent. Electrically, they behave as if they are located directly on dendrites.
Thousands of dendritic spines on individual neurons process information and mediate plasticity by generating electrical input signals using a sophisticated assembly of transmitter receptors and voltage-sensitive ion channel molecules. Our understanding, however, of the electrical behaviour of spines is limited because it has not been possible to record input signals from these structures with adequate sensitivity and spatiotemporal resolution. Current interpretation of indirect data and speculations based on theoretical considerations are inconclusive. Here we use an electrochromic voltage-sensitive dye which acts as a transmembrane optical voltmeter with a linear scale to directly monitor electrical signals from individual spines on thin basal dendrites. The results show that synapses on these spines are not electrically isolated by the spine neck to a significant extent. Electrically, they behave as if they are located directly on dendrites.
Spines are small (∼1 μm) membrane protrusions from
dendrites which receive most of the excitatory synaptic inputs in the mammalian brain.
They are of critical importance because they utilize a complex assembly of transmitter
receptors and voltage-sensitive ion channel molecules1 to process
electrical input signals and to mediate synaptic plasticity that may underlie learning
and memory2. There is, however, no direct information on the electrical
behaviour of spines because it has not been possible, for technical reasons, to measure
the generation and spread of input signals from the spine to the dendrite. Theoretical
considerations show that the main determining factor for the electrical role of
dendritic spines is the electrical resistance of the spine neck
(Rneck) relative to the input impedance of the parent dendrite
(Zdendrite)34567. Obtaining direct evidence
on these variables requires a method for monitoring subthreshold membrane potential
responses simultaneously from the spine head and the parent dendrite as well as a
technique for a selective activation of individual excitatory synapses on the spine
head. Methods for selective activation of individual synapses have been developed using
iontophoresis from sharp microelectrodes8 and later improved by
two-photon uncaging of glutamate91011. However, recording of
subthreshold synaptic responses at the spatial scale of individual spines with the
sensitivity and temporal resolution adequate for quantitative analysis has been a major
challenge. A notable attempt to optically monitor subthreshold signals from individual
spines12 was based on the realization that electrochromic
voltage-sensitive dyes13 might be utilized to achieve that goal. However,
due to low sensitivity of the recording method that study could not provide conclusive
evidence.Here, we used an advanced version of electrochromic voltage-sensitive dye technique14 which allowed us to directly measure subthreshold excitatory
postsynaptic potential (EPSP) signals from individual spines and quantify electrical
resistance of the spine neck. The EPSP signals were evoked by selective activation of
individual synapses of layer 5 cortical pyramidal neurons of the mouse using focal
glutamate release. The results demonstrated that synapses on spines of thin basal
dendrites are not electrically isolated by the spine neck to a significant extent. Thus,
in our measurements, spines with a variety of morphological features behaved the same in
terms of electrical signalling. The optical approach described here lights the way to
future studies of how particular combinations of transmitter receptors and
voltage-sensitive ion channels in different spines15 act in concert to
shape the integration of chemical input signals at the site of origin.
Results
Sensitivity of optical recording
A critical concern of this study was the sensitivity of optical recordings in
terms of the signal-to-noise ratio (S/N) at the required
spatiotemporal resolution. The best existing sensitivity which allowed optical
monitoring of back-propagating action potentials (bAP) from dendritic
spines14 was insufficient because EPSP signals would be
5–10 fold smaller in amplitude. The required improvement in
sensitivity was accomplished by further increase in the excitation light
intensity using a laser at the wavelength that has the best signal, by
minimizing photodynamic damage by restricting the excitation light to a small
area (18 μm × 18 μm), and
by briefly lowering oxygen concentration in the extracellular solution during
optical recording (Methods). The sensitivity of optical recording under these
conditions is illustrated in Fig. 1. An image of a
cortical layer 5 pyramidal neuron situated in the superficial layer of the slice
(<30 μm from the surface) and labelled with the
voltage-sensitive dye was projected onto a charge-coupled device camera (CCD)
for voltage imaging at high magnification so that individual spines could be
clearly resolved (Fig. 1b). We selected spines that were
isolated from their neighbours both in x–y and in
z dimension; the selection was biased against spines with small heads
because these were characterized with poor signal-to-noise ratio. The range of
distances from the soma along the basal dendrite was
30–120 μm. In a representative experiment shown
in Fig. 1, a subthreshold depolarizing transient followed
by an action potential were evoked by two current pulses delivered from a
somatic patch electrode while optical signals were acquired at a frame rate of
2 kHz from a small segment of a basal dendrite with several spines.
Both the subthreshold membrane potential signal and the action potential signal
can be clearly resolved in optical recordings from the three spine heads and the
parent dendrite with modest signal averaging (temporal average of 16 trials;
Fig. 1c). As a rule, the amplitudes of optical signals
related to the same electrical event are different when recorded from different
neuronal compartments reflecting differences in recording sensitivity due to
variability in the surface-to-volume ratio16. Thus, it is
necessary to calibrate optical signals on an absolute scale (in mV) to compare
signal amplitudes. This was accomplished by normalizing the subthreshold signals
to an optical signal from a bAP1216 which has a known declining
amplitude along basal dendrites, as previously determined by patch-pipette
recordings1217. The subthreshold and AP optical signals can
also be calibrated using long hyperpolarizing pulses delivered to the soma1218, which attenuate relatively little as they propagate along
dendrites1719. Both methods of calibration have to be
regarded as an approximation due to a known individual variability between
neurons and possible inaccuracies in patch-pipette recordings from thin
dendrites20. However, we determined that the margin of
calibration error is sufficiently small that it does not influence the
conclusions of our study (see below). Throughout this study, we used bAP signals
as calibration standards because they are substantially shorter compared with
steady state hyperpolarizing steps and, thus, less susceptible to slow noise,
dye bleaching effects and photodynamic damage. We experimentally confirmed the
result previously reported by Palmer and Stuart12 showing that
both methods of calibration produce the same results (Supplementary Fig. 1, Methods). In the
experiment shown in Fig. 1, the size of the AP measured
with an electrode in the soma was 110 mV which corresponds to an
average value of 80±10 mV bAP in the basal dendrite at a
distance of ∼50 μm from the cell body17 where the spine was located; in all experiments, the bAP
amplitude at a distance corresponding to spine position on the basal dendrite
was used as a calibration standard. The subthreshold electrical signals that
were initiated in the soma are expected to be identical in the three spines and
the parent dendrite within the ∼10-μm long dendritic segment
shown in Fig. 1. This is because both theory and
experiments demonstrated that electrical signals do not attenuate as they
propagate from the dendrite into the spines41214. Calibrated
subthreshold signals were indeed identical within a fraction of a millivolt as
shown in Fig. 1d.
Figure 1
Sensitivity of recording.
(a) Voltage-sensitive dye fluorescence image of a neuron; confocal,
z-stack projection. Bright rectangle: illuminated recording
region. (b) High magnification single frame image focused on the
spine inside the red circle obtained with the CCD for voltage imaging.
(c) Subthreshold and AP optical signals from colour-coded
multiple locations (temporal average of 16 trials; spatial average of pixels
within coloured outlines). Black traces: somatic patch electrode recording
(upper trace); transmembrane current pulses (lower trace). (d)
Optical signals calibrated in terms of membrane potential using bAP signal
as calibration standard. The amplitude resolution was improved by additional
temporal averaging (the thickness of the grey line is 1 mV;
average of 80 trials). The differences in after-depolarization recorded from
different locations are not reproducible and likely reflect interaction
between slow noise and the exponential subtraction routine used to
compensate for dye bleaching. The recording sensitivity shown in c
was routinely achieved in all measurements (n=29).
Linearity and photodynamic damage
Correct interpretation of optical recordings of membrane potential transients
depends on two basic requirements: (a) light intensity has to be linearly
proportional to membrane potential over the range of signal amplitudes; (b) to
allow signal averaging, the electrical response under study has to be stable
throughout the experiment indicating the absence of photodynamic damage. We
confirmed that both requirements were met (Fig. 2,
Methods).
Figure 2
Linearity and photodynamic damage.
(a) Superimposed electrical and optical recordings of an evoked bAP.
Dye signal (green trace) from dendritic area outlined by green line is
linearly related to membrane potential recorded with patch electrode (black
trace). (b) The 1st and the 50th 20 ms optical recording
trial of the evoked bAP signals from basal dendrite (spatial average of
pixels within green outline). Photodynamic damage is small or absent. The
small difference in AP size and shape is a common result of preparation
rundown. (c) Single frame voltage-sensitive dye fluorescence image of
a spine in recording position. Red dot: uncaging location. (d)
Individual (grey) and average (black) responses of the first (1–4)
and the last (8–12) eEPSP signals evoked by repetitive two-photon
uncaging of glutamate as recorded by a somatic patch electrode. (e)
Optical recordings of the same eEPSP signals from the outlined area (green
line) on the parent dendrite at the base of the spine. Optical signals
(green line) are average of four trials. Photodynamic damage is not
detectable. Linearity and absence of photodynamic damage has been confirmed
in all experiments (n=29).
Spatial resolution
Another critical parameter is the spatial resolution that can be achieved in
wide-field epifluorescence microscopy mode, which has to be adequate to allow
recording of spine and dendrite signals separately. To maximize spatial
resolution, all measurements were made from spiny basal dendrites in the
superficial layer of the slice (Methods). However, because signal contamination
due to light scattering depends not only on recording depth but also on other
structural and geometrical factors, the extent of light scattering was
determined in every experiment. The amount of light scattered from the spine
head to the dendrite was estimated by comparing bAP signals from the spine head
and from an unstained area equivalent in size to the parent dendrite and at the
same distance from the spine (Fig. 3a,b). The amount of
light scattered from the dendrite to the spine head was estimated by comparing
recordings from the spine head and from an analogous location at the same
distance from the dendrite which contained no stained structures (Fig. 3a,b). The summary result from 29 spines analysed in this study
(Fig. 3c) indicates that the amount of light scattered
from the spine to the dendrite was negligible (3±0.3%;
median 3%, range 0.2–6%) as expected from the
ratio of membrane surface areas. The amount of light scattered from the dendrite
to the spine was 10±0.9% (median 9.7%; range
1–20%). It is possible to estimate whether this amount of
scattering will cause significant change in the EPSP signal recorded from the
spine head. If one makes an assumption that the amplitude of the true EPSP
related fractional signal (ΔF/F) from the spine head is
equal to 1 and the one from the dendrite is equal to 0.5 (a hypothetical
attenuation across the spine neck of 50%), the recorded optical
signal will be composed of 90% of the light carrying the fractional
signal from the spine head equal to 1 and 10% of the light carrying
the fractional signal from the dendrite equal to 0.5. The recorded composite
fractional signal will be 0.95, a 5% error from the true EPSP
amplitude of 1 in this example. Even for the extreme (unrealistic) attenuation
of EPSP amplitude across the spine neck of 99%, the upper bound for
the error would be <10%. It will be shown below that, in our
measurements, the actual error due to light scattering has to be much less than
5% and, thus, negligible. This is because the recorded amplitudes of
the EPSP signals, even assuming an error of 10%, indicated that the
attenuation across the spine neck is ∼10%, considerably less
than a hypothetical value of 50% used above.
Figure 3
Light scattering.
(a) Optical signals related to an evoked bAP from a stubby spine head
and from an unstained area receiving scattered light. Signals are from areas
outlined by corresponding colour lines. The ratio of the spine signal
amplitude (red trace) and the amplitude of the signal from an area without
spine (blue trace) is a measure of the amount of light scattering from the
dendrite to the spine. The ratio of the spine signal amplitude (red trace)
and the amplitude of the signal from an unstained area (green trace) at the
distance from the spine head equal to the distance of the parent dendrite is
a measure of the amount of light scattering from the spine to the dendrite.
(b) Same test for a long neck mushroom spine. (c) Scatter
plots and mean values for scattered light contribution to dendritic and
spine head signals; summary data from n=29 experiments.
Standard errors of the mean are smaller than red symbols.
Selective activation of individual spines
The analysis of EPSP signals from spines requires selective activation of
individual synapses to eliminate uncertainties about the source of the signal. A
reliable selective activation of one spine/synapse using physiological synaptic
stimulation is not presently realizable. While it is possible, although
difficult, to insure a reliable repetitive activation of only one individual
presynaptic axons, one cannot assume that no more than one synapse is
activated12. It is known that practically every presynaptic
axon makes more than one functional contact (synapse) with any postsynaptic
neuron. Thus, even a minimal stimulation of one presynaptic axon will result, as
a rule, in activation of multiple synapses1221.To insure that no more than one spine is activated we initially took advantage of
micro-iontophoresis of glutamate onto individual spines from a high-resistance
sharp electrode as developed in cell culture8. We extended this
method to brain slices and confirmed the previously demonstrated spatiotemporal
resolution (Fig. 4, Methods). However, micro-iontophoresis
suffers from inherently low success rate (∼5%) in experiments
that required multiple and reproducible activation of synapses because
high-resistance electrodes are notoriously unstable. Thus, in later experiments,
we used photolysis of caged glutamate in a diffraction-limited volume based on
two-photon light absorption. The firmly established91022
diffraction-limited spatial resolution of two-photon glutamate uncaging was
verified in our measurements (Supplementary Fig. 2, Methods). Glutamate release using both
iontophoresis and two-photon uncaging was standardized to evoke EPSPs in the
soma in the range of 0.2–0.8 mV. These values correspond
well to somatic recordings of physiological unitary EPSPs under optically
confirmed activation of one individual spine on a neuron21.
Figure 4
Spatiotemporal resolution of glutamate release.
(a) A typical release profile with sub micrometre resolution of
iontophoresis of a fluorescent dye with molecular weight similar to
glutamate. (b) Light intensity as a function of distance from the tip
of the sharp electrode. (c,d) An excitatory postsynaptic
current of 15 pA recorded from the soma following focal glutamate
iontophoresis onto an individual spine head. Repeated iontophoresis produced
consistent responses; compare single trial and average of nine trials.
Glutamate selectively activated the synapse on the spine head; placing the
electrode at the same distance from the dendrite but away from the spine
head resulted in no measurable response. This control measurements were
carried out in n=19 experiments. (e) Fluorescence
image of a spine positioned in close proximity
(∼0.5 μm) to the uncaging site. (f)
Synaptic current response to iontophoretic release of glutamate (green
trace) adjusted to approximate the amplitude and time course of a
spontaneous miniature EPSC (black trace). (g) Synaptic current
response to two-photon uncaging of glutamate (red trace) adjusted to
approximate the amplitude and time course of a spontaneous miniature EPSCs
(black trace). The average 10–90% rise time and full
width at half height (FWHH) of the spontaneous EPSC recorded in the soma
were 1.2±0.1 ms and 5.9±0.4 ms,
respectively (n=8). Corresponding values for
uncaging-evoked responses were 2.1±0.2 ms and
6.1±0.3 (n=10) while EPSC evoked by
iontophoresis where characterized with rise time of
2.9±0.2 ms and FWHH of 12±0.6 ms
(n=19).
Electrical coupling across the spine neck
To characterize electrical coupling across the spine neck we monitored evoked
subthreshold signals (eEPSP) following brief focal application of glutamate. A
representative experiment utilizing micro-iontophoresis is shown in Fig. 5a–e. The tip of the sharp electrode was
positioned in close proximity to a spatially isolated spine (Fig.
5a–c) and the iontophoretic current was adjusted so that
the eEPSP in the soma (Fig. 5d) was in the range of
unitary synaptic events (0.2–0.8 mV). The eEPSP signal was
recorded optically from the spine head and from the parent dendrite followed by
the recording of the bAP signals from the same locations (Fig.
5d). The EPSP signals were calibrated in mV using the bAP signal as a
calibration standard (scaled signals in Fig. 5e). The
significance of possible errors in calibrating optical signals is discussed
below. From the measured eEPSPspine, eEPSPdendrite and
Isynapse (recorded separately under voltage clamp in
response to a standard glutamate release adjusted to evoke EPSPs in the soma
corresponding to somatic recordings of physiological unitary EPSPs) we
calculated Rneck and Zdendrite (Fig. 5k–m) according to the equations in Fig. 5o applied to the equivalent electrical circuit shown
in Supplementary Fig. 3b. The
equations in Fig. 5o are derived as time integrals of
Ohm's law applied to a voltage divider representing a spine attached
to a dendrite (Supplementary Fig.
3c). This approach integrated synaptic current
(Isynapse) over time to arrive at the recorded synaptic
charge transfer (Qclamp) which was subsequently corrected for
the error caused by incomplete space clamp. Integrating synaptic current to
estimate transferred charge minimizes somatic voltage clamp error23. The significance of this error is discussed below. In the experiment shown
in Fig. 5a–e, Rneck and
Zdendrite, calculated from measured parameters, were 15
and 197 MΩ, respectively. Figure
5f–j shows an example of a similar experiment utilizing
two-photon uncaging of glutamate. Again, it is clear that the eEPSP signals in
the spine head and in the parent dendrite (Fig. 5i) are
similar indicating that Rneck is negligible compared with
Zdendrite. In this experiment Rneck and
Zdendrite, calculated from the measured parameters, were
29 and 371 MΩ, respectively. Figure 6
illustrates three additional measurements utilizing two-photon uncaging. The
scatter plots of data from n=29/24/22 (spines/cells/animals)
experiments showed the mean values of
Rneck=27±6 MΩ and
Zdendrite=275±27 MΩ.
Figure 5
Quantification of
R
neck
and
Z
dendrite
from two representative experimental measurements.
(a) Low-magnification fluorescence image of a basal dendrite labelled
with a voltage-sensitive dye; z-stack of confocal images. Arrow:
recorded spine. (b) High magnification confocal image of the same
spine. Tip of iontophoretic electrode (labelled with the fluorescent dye) in
the immediate vicinity of spine head. (c) Single frame image of a
spine in recording position obtained with CCD for voltage imaging.
(d) Traces on left: eEPSP recordings from spine head (red) and parent
dendrite (green). Average of 16 trials. Bottom black traces: somatic
electrode recording and the uncaging command pulse. Traces on right: bAP
signals from same locations. Average of nine trials. (e) Left traces:
superimposed eEPSP signals from spine head and parent dendrite calibrated in
terms of membrane potential. Right traces: bAP signals corrected for
recording sensitivity difference. (f–j) Two-photon
uncaging of glutamate. Same information as shown in
a–e. Red dot in h: position and
approximate size of uncaging light spot. The eEPSP and bAP recordings are
average of 8 and 4 trials, respectively. (k) Synaptic current in
response to standard focal application of glutamate. Grey area: time
integral of synaptic current. (l) Superimposed eEPSP signals from
spine head (red) and parent dendrite (green) calibrated in mV. (m)
Time integral of synaptic current. (n) Time integral of voltage drop
across spine neck. (o) Equations for Rneck and
Zdendrite calculation.
Vdendrite—local dendritic membrane potential;
Vspine—membrane potential of the spine head;
Isynapse—synaptic current;
Rneck—electrical resistance of spine neck;
Zdendrite—impedance of parent dendrite;
Qclamp—total recorded charge transfer;
Ks-d: distance-dependent adjustment factor for the
correction of the somatic voltage clamp error based on experimentally
determined dendro-somatic attenuation of synaptic charge transfer23.
Figure 6
Attenuation ratio
eEPSPspine/eEPSPdendrite.
(a) The attenuation ratio is directly determined by the ratio of
resistances as shown by the equation at the top. Three representative
examples of the comparison of eEPSPspine (red) and
eEPSPdendrite (green) evoked by two-photon uncaging of
glutamate. In each panel, two fluorescent images are shown on left. Upper:
z-stack of confocal images. Lower: single frame image of a spine
in recording position. Red dot: uncaging location. Lower black traces:
somatic patch electrode recordings and timing of uncaging pulse. From top to
bottom: averages of 24, 16 and 4 trials. (b) Scatter plot of
individual values and the mean Rneck. (c) Scatter
plot of individual values and the mean Zdendrite.
(d) Scatter plot of individual values and the mean ratios
Rneck/Zdendrite (left scale) and
eEPSPspine/eEPSPdendrite (right scale).
N=29 in all cases. In c and d s.e.m. is
smaller than the red data mark. () Iontophoresis. () 2P uncaging.
Quantification accuracy
How accurate is our quantification of Rneck and
Zdendrite? There are four possible sources of errors that
need to be considered: (a) sampling frequency, (b) the S/Nratio,
(c) calibration of optical signals in terms of membrane potential and (d)
voltage-clamp measurement of unitary synaptic current/transferred charge. The
sampling frequency (frame rate) was limited by the available S/N
to 2 kHz. The duration of the upstroke of the EPSP
(threshold-to-peak) as recorded electrically by others at a sampling rate of
50 KHz is in the range of 1–2 ms (refs 17, 23, 24, 25). In our study, the average
10–90% rise time of optically recorded eEPSPs was
1.2±0.1 ms while the full width at the half height was
5.9±0.4 ms; n=29. Our sampling rate of
2 kHz, although lower than the formally required Nyquist rate, was
sufficient for the accurate reconstruction of EPSP waveform because aliasing
(sampling artefact which can result in the omission of additional peaks in
between data points) can be safely excluded on the basis of additional
information available from independent measurements; the general shape of the
EPSP is known from dendritic electrical recordings25. These
electrical data correspond well with our optical recordings from the parent
dendrite.At the sampling rate of 2 kHz, optical recordings were averaged over
4–16 trials (and rarely up to 25 trials) to reach the
S/N of ∼4. The mean S/N in recordings
from n=29 spines was 4.3±0.3
(mean±s.e.m.). Due to the larger membrane area, the sensitivity of
recordings from the parent dendrites at the base of the spine was significantly
higher with the S/N=9.4±2.3. We assumed that
the high sensitivity recordings from the parent dendrite are an accurate measure
of the true waveform of the eEPSP both in the parent dendrite and in the spine
head because the waveform is expected to be practically identical in both
compartments. The membrane area of the spine neck and its effective capacitance
is extremely small rendering RC filtering across the
∼1 μm long spine neck cable negligible. In
addition, regarding the S/N, the calculation of the
Rneck and Zdendrite is based on the time
integral of EPSP signals from spines and dendrites. As illustrated in Fig. 5m,n, integration of the EPSP voltage trace over time
acts as a powerful low-pass filter which practically eliminated random
high-frequency noise. Thus, we conclude that the quantification of
Rneck and Zdendrite was based on
adequate sensitivity and sampling rate.There are unavoidable inaccuracies in calibrating optical signals in terms of
membrane potential. However, it is possible to determine calibration error
limits and establish whether the results and conclusions of the study could be
significantly affected. The amplitude of the bAP signals measured electrically
from basal dendrites1217 varied from ∼100 mV
at a distance of about 30 μm down to
∼45 mV at a distance of about 120 μm
from the soma. Within this range, at any given distance, individual values may
vary around the exponential fit to the data by ∼20 mV (ref.
17). Additionally, there are uncertainties
about the precision of electrical measurements from thin dendrites which are
often ignored. The accuracy of electrical measurements using high-resistance
patch electrodes (∼100 MΩ) depends steeply on
series resistance and capacitance compensation (which are never perfect).
Moreover, patch electrodes introduce additional capacitive load on the dendrite
resulting from the capacitance of the pipette that cannot be compensated for
(ref. 20). These factors would lead to
underestimation of the extent of AP backpropagation. Indeed, voltage-imaging
studies showed that the amplitude of bAPs in distal basal dendrite might be
larger than what was indicated by electrode measurements26. To
take into account these uncertainties, we calibrated EPSP signals for all spines
(regardless of the distance from the soma) using both the low-end of the bAP
amplitude range (45 mV) and the high-end value of 100 mV.
The results showed that the mean Rneck values based on low-
and high-end bAP amplitudes were 22.5 ±4.8 MΩ
and 43.7±9.7 MΩ, respectively. This result sets
the upper and lower limits for Rneck values indicating that
possible errors in calibrating optical signals are too small to influence the
conclusions from this study. The mean value of
26.7±6.3 MΩ, obtained by adjusting bAP amplitude
as a function of distance from the soma according to the exponential fit to
individual data1217 appears to be the most accurate estimate
that can be currently obtained.Due to incomplete space clamp, the somatic voltage clamp does not report accurate
synaptic currents or transferred charge. To minimize these errors, we used the
correction factors taken directly from Fig. 3a of Williams
and Mitchell23. That figure reports the experimentally determined
dendro-somatic attenuation of transferred synaptic charge as a function of
distance of the synapse from the recording site (cell body) expressed as a
fraction of recovered charge. In every experiment, we used the value of this
fraction at the corresponding distance (as determined from the confocal image of
the cell) as the correction factor (Ks-d). The range of
distances in our experiments was 30–120 μm
(Methods) corresponding to a fraction of recovered charge in the range of
75–95%. However, the direct measurements of dendro-somatic
attenuation by Williams and Mitchell23 were carried out from
primary apical dendrites. Thus, our calculations of the synaptic currents are
likely to be underestimates because apical dendritic trunksare characterized by
larger diameter and, hence, lower axial resistance compared with basal
dendrites. For this reason the charge loss is expected to be larger in basal
dendrites. We conclude that our results set the lower limit for current
amplitudes at the site of origin which translates into upper bound for
calculated spine neck resistance.It is important to recognize that, in addition to being small, the errors in
calibrating optical signals as well as in estimating current amplitudes have no
effect on the ratio of resistances because both resistances are equally
affected. This is of particular significance because, from the functional point
of view, the absolute values of the Rneck and
Zdendriteare less important than the ratio of resistances
which directly determines the attenuation ratio
eEPSPspine/eEPSPdendrite (AR) (Fig.
6a; Supplementary Fig.
3). The AR, in turn, determines the effect of a synapse on the membrane
potential of a neuron (synaptic weight). It follows from these considerations
that AR can be measured directly from optical recordings without any assumptions
and with accuracy limited only by the S/N. The scatter plot of the
data from 29 experiments indicated mean value for
AR=1.10±0.02 (Fig. 6d). In other
words, on average, eEPSPs in the spine head are attenuated as they propagate
across the spine neck by ∼10% with a significant proportion
of spines (∼60%) showing lower attenuation.
The role of voltage-sensitive channels in spines
The conceptual model used for Rneck calculation (Supplementary Fig. 3) is valid only if
voltage-sensitive channels in the parent dendrite do not contribute
significantly to eEPSPdendrite amplitude. We used a pharmacological
test to measure this contribution (which is currently unsettled122728). The eEPSP amplitudes were measured under control
conditions and in the presence of a cocktail of pharmacological agents that
selectively block NMDA receptors as well as Na2+ and
Ca2+ voltage-sensitive channels (Fig.
7, Methods). In these measurements, it was sufficient to monitor
eEPSP signals from a small section (∼20 μm in
length; Fig. 7) of the dendrite at the base of the spine.
These signals provide accurate information about changes in the synaptic current
and eEPSP amplitude while the recording from the relatively large dendritic
membrane area relaxes the requirement for signal averaging. The summary result
from n=7/6/6 experiments (spines/cells/animals) showed that
the pharmacological block of voltage-sensitive channels did not reduce the
amplitude of the eEPSP
(eEPSPcontrol/eEPSPblockers=1.006±0.05;
P<0.01; Student's t-test). These data argue
that the contribution of voltage-sensitive channels to unitary eEPSPs was not
significant.
Figure 7
A representative example of the effect of channel blockers on eEPSP
amplitude.
Left panel: fluorescence image of a section of basal dendrite with one spine
in focus; uncaging location indicated by red dot. Right panel: top traces:
optical recordings of the eEPSPdendrite signals from outlined
dendritic area (green) evoked under control conditions and in the presence
of a cocktail of channel blockers (1 μM TTX,
100 μM AP-5, 10 μM nimodipine,
100 μM NiCl2). Average of 4 trials. No
effect of channel blockers detected. Middle traces: somatic electrode
recordings of eEPSP. Bottom traces: timing of the uncaging pulse.
Computational modelling
To establish how our experimental results correspond to widely accepted
electrical behaviour of dendritic cables we constructed a multicompartmental
model of a layer 5 pyramidal neuron with typical passive dendritic cable
properties (Methods) and experimentally determined dendritic diameters from live
neurons (Supplementary Fig. 4). The
model predicts the amplitude and the time course of EPSPspine,
EPSPdendrite and
AR=1+Rneck/Zdendrite
(refs 3, 4, 5, 6) for a given
Isynapse, according to Ohm's law and
Kirchhoff's current law for spines at different locations (Fig. 8; Supplementary
Fig. 3). In a series of simulations, the position of a typical spine
(neck length 1 μm; diameter
0.17 μm)7 attached to a parent dendrite
was moved across the entire dendritic arbour. The EPSPspine,
EPSPdendrite, Zdendrite and AR were calculated
for every location after the spine was activated with a conductance change
synapse model adjusted to mimic a unitary EPSC21. The
colour-coded display of the results illustrates spatial distribution of the four
parameters mentioned above (Fig. 8b). Because the
calculated Zdendrite was much larger than
Rneck in most parts of the dendritic tree (a fact that is
not universally appreciated29), the AR was close to unity
(between 1 and 1.1) in these distal regions (Fig. 8b,
right-most model result). For a typical basal dendrite the model predicted a
ratio of 1.5, 1.3 and <1.1 at distances of 20, 30 and
>60 μm from the soma. This modelling prediction
corresponds well to the range of recorded values shown in Fig.
6d. The exception from this rule was the proximal primary dendritic
trunk characterized by large diameter and a very low
Zdendrite, comparable to the value of Rneck
of the standard spine (∼30 MΩ). The AR in these
proximal regions varied between 1.5 and 3 indicating that the EPSP in these
spines was up to 3 times larger than in the dendrites at the base of the spine.
However, larger attenuation in these spines is based on low
Zdendrite, not on large Rneck. Thus, the
overall input impedance of a proximal spine
(Zspine=Rneck+Zdendrite)
is low and, consequently, the peak amplitude of EPSPs produced in these spines
is expected to be low. Patch-clamp recordings from basal dendrites confirmed
this expectation (Nevian et al.17). Notably, these
proximal dendritic compartments are largely devoid of spines30.
Another consequence of much larger Zdendrite relative to
Rneck over most of the dendritic tree was that the spatial
distribution of EPSPspine amplitudes was highly non-uniform and
similar to the spatial distribution of both Zdendrite and
EPSPdendrite amplitudes (Fig. 8b, left
three model results). This result shows that, in the model,
Zdendrite is the main determinant of the EPSP amplitude in
both compartments (spine and dendrite) while the effect of
Rneck is small and limited to proximal parts of the
primary apical dendrite. Our experimental measurements are in full agreement
with these modelling predictions.
Figure 8
Numerical simulation.
(a) Activated synapse on a spine attached to a basal dendrite
120 μm from the soma generated EPSP signal of
10 mV in the spine head, 9.3 mV in the parent
dendrite, and 0.3 mV in the soma. The best fit of the size and
shape of the EPSP signal corresponded to
Rneck=40.5 MΩ and
Zdendrite=564 MΩ.
(b) A series of simulations with EPSPspine and
EPSPdendrite computed for a standard spine attached to all
dendritic compartments (one at a time). Colour-coded display: spatial
distributions of Zdendrite, EPSPspine, and
EPSPdendrite are similar while AR was close to unity for the
majority of synapses in the dendritic tree.
Discussion
On the conceptual level, a key question that has not been answered is whether the
hypothetical electrical isolation of synapses on spine heads caused by a narrow
spine neck is responsible for specific functions which are not supported by synapses
on dendrites. Current interpretations of indirect morphological evidence73132, optical recordings of diffusional exchange across the spine
neck732333435, optical recordings of membrane potential
and [Ca2+] signals6123236, and modelling studies45628 have not
provided a consistent and unifying description of the electrical behaviour of
spines.We utilized a technique based on an electrochromic voltage-sensitive dye which can be
thought of as a transmembrane optical voltmeter with a linear scale capable of
monitoring simultaneously electrical signals from individual spines and parent
dendrites. Our study provides direct evidence that the resistance of the neck in
spines on thin basal dendrites is too low to electrically isolate synapses on spine
heads to an extent that would have functional consequences. In other words, in
strictly electrical terms, the experimental data argue that synapses on spines of
thin basal dendrites behave as if they are located directly on dendrites. We also
found that the contribution of voltage-sensitive channels to unitary eEPSPs was not
significant in these spines. Interestingly, a recent study demonstrated that this
conclusion cannot be extrapolated to a specific class of spines found on granule
cells of the olfactory bulb28. A fundamental implication of our
findings is that spines on thin basal dendrites are characterized by uniform
electrical behaviour regardless of considerable short-term and long-term variations
in their morphology73129.The average value of Rneck determined in our experiments
(∼30 MΩ) is in full agreement with pioneering35 as well as several subsequent estimates from measurements of
diffusional equilibration across the spine neck in the majority
(∼95%) of spines under physiological conditions7323334. A recent estimate of the spine neck resistance, based on
supra-resolution (STED) morphological data and diffusional equilibration
measurements using fluorescence recovery after photobleaching (FRAP) technique,
indicated Rneck value centred around 56 MΩ
(ref. 7). Allowing for the uncertainties about the true
values for both the resistivity of the intracellular medium and the diffusion
coefficients, that estimate of Rneck is in good agreement with our
measurements. Additional strong evidence in support of low Rneck
is a striking lack of correlation between spine neck lengths (varying within a wide
range of 0–10 μm) and the EPSP rise time and
associated Ca2+ signal in the spine head, as recently
reported for exceptionally long spines on granule cells of the olfactory bulb28. Similar study based on morphological STED data and diffusional FRAP
measurements from spines of CA1 pyramidal neurons reported the same lack of
correlation between spine dimensions (neck length and diameter) on one hand and
evoked EPSPs in the soma and Ca2+ transient in the spine
head on the other hand32. These results are in agreement with the
main implication of our study that electrical behaviour of spines is independent of
their morphology. The reported lack of correlation is expected if
Rneck varies with neck dimensions and diffusional resistance
(as governed by elementary principles of chemical diffusion and electrical current
flow) but stays within a range of values that are much smaller relative to
Zdendrite (except in proximal thick dendrites characterized by
low Zdendrite). The agreement between our voltage-imaging results
and prior diffusional measurements is critical because, due to the close analogy
between diffusional and electrotonic coupling across the spine neck, it is difficult
to argue against strong implications of diffusional measurements for the upper bound
of the possible electrical resistance of the spine neck. In this context, it should
be emphasized that there is strong evidence for a small percentage of spines
(∼5%) that show high diffusional isolation of the spine head73334. These exceptional spines are currently not well
understood.The only, to our knowledge, prior voltage-sensitive dye study of subthreshold signals
from dendritic spines12 reported that it was difficult to detect
spine voltage responses in the majority of spines while a relatively small subset of
spines (∼18%) were characterized by responses that ranged from 0
to 25 mV. In a larger subset of spines (82%) no clear
responses could be detected, a result consistent with low spine neck resistance. The
comparison of this study with our data is difficult due to several technical
limitations. First, the study of Palmer and Stuart12 did not
selectively activate individual synapses on spines. Therefore, it was not possible
to arrive at accurate information on the spine neck resistance or the attenuation of
the EPSP across the spine neck. As stated in their paper, their extracellular
stimulation activated multiple synaptic inputs resulting in an average somatic EPSP
of ∼5 mV. A somatic EPSP of this magnitude corresponds to
activation of 6–25 synapses624 generating background
depolarization from inputs other that the activated spine. This background
depolarization of unknown amplitude will spread instantaneously from the parent
dendrite into the spine head without any voltage loss making it impossible to know
isolated spine response. In this situation the result of the described subtraction
of the response in the parent dendrite from the spine response is undefined.
Additionally, Palmer and Stuart12 selected a small subset of spine
recordings with the largest observed responses to estimate, in a computer model,
that the upper bound for the spine neck resistance was
∼500 MΩ. They went on to show, in a model, that even an
extreme resistance of 500 MΩ is not expected to cause
significant synaptic saturation which would modify the somatic EPSP. Thus, similar
to our results, their estimates ruled out significant electrical isolation of
synapses on dendritic spines.There is a discrepancy between our voltage-imaging measurements and the
interpretations of indirect evidence from several experimental studies based on
optical recording of intracellularcalcium concentration changes6293637 which had suggested high electrical isolation of synapses
by the spine neck. High electrical isolation of synapses on spines, in turn, had
been hypothesized to reduce location-dependent variability of local EPSP amplitude
and kinetics and to standardize synaptic activation of NMDA receptors and
voltage-gated channels thereby promoting nonlinear dendritic processing and
associated forms of plasticity and storage562938. The recent
study of Harnett et al.6 based on calcium imaging indicated
Rneck of ∼500 MΩ, an order of
magnitude higher than our estimate. It should be emphasized that the pattern of the
colour-coded spatial distribution of Zdendrite and AR reported in
that study (Fig. 3 in Harnett et al.6)
is similar to our modelling result. This similarity is expected because any model
based on a constant spine neck resistance and variable dendritic input impedance
will result in a spatial pattern of AR which follows the classical spatial
distribution of local dendritic input impedance. This outcome is independent of the
absolute value of the Rneck. At the moment, there is no clear
explanation for the discrepancy in estimating Rneck. Calcium
concentration changes are indirect, slow, and highly nonlinear indicator of
transmembrane voltage changes. Additionally, the nonlinear relationship between
calcium signals and transmembrane voltage is unstable due to high sensitivity of the
state of calcium channels to the history of the resting membrane potential. Thus, it
is important to verify the conclusions of studies based on calcium imaging by a more
direct approach especially because these conclusions dramatically contradict
diffusional resistance measurements as well as the predictions from classical
biophysical modelling of dendritic cables. As stated above, an additional strong
argument against high spine neck resistance are the two most recent studies based on
Ca2+ measurements that failed to find significant
correlation between the dimensions of the spine neck and uncaging-evoked EPSPs and
Ca2+ transients2832.To summarize, direct measurements of Rneck and
Zdendrite reported here argue against high
Rneck for the spines on thin basal dendrites and against all
of the hypothetical functional implications of the electrical isolation of synapses
on these spines. It remains to be investigated whether spines on other parts of the
dendritic arbour and in other neuronal types behave in the same manner. The optical
approach described here provides a path for these future studies. More generally, we
predict that the voltage-imaging approach will be instrumental in facilitating the
answer to the central question in spine physiology: what is the mechanism by which
complex ensembles of specific transmitter receptors and voltage-sensitive ion
channels localized to spine heads act in concert to shape the plastic integration of
repetitive chemical input signals carried out by dendritic spines.
Methods
Slices, patch-clamp recording and intracellular application of
dyes
All surgical and experimental procedures were performed in accordance with Public
Health Service Policy on Humane Care and Use of Laboratory Animals and approved
by Yale University Institutional Animal Care and Use Committee. Experiments were
carried out on somatosensory cortex slices from 18 to 30-day-old mice of either
sex. In about 50% of the experiments we used wild-type mice (Swiss
Webster (CFW), Harlan Laboratories, Indianapolis); the remainder of the data
were obtained using a transgenic mouse line (Gene symbol: Crym) characterized by
EGFP positive pyramidal neurons in cortical layers 5 and 6. Crymmice were
obtained from the GENSAT Project at The Rockefeller University. No difference in
results from these two groups was detected. The mice were decapitated following
deep sodium pentobarbital
(50 mg kg−1) anaesthesia, the
brain was quickly removed, and 300 μm thick coronal
cortical slices were cut in ice-cold solution using a custom made rotary slicer
with circular blade (Specialty Blades Inc., Staunton, VA, USA). Slices were
incubated at 37 ° C for ∼30 min and then
maintained at room temperature (23–25 ° C). The
standard extracellular solution used during recording contained (in mM): 125
NaCl, 25 NaHCO3, 20 glucose, 2.5 KCl, 1.25
NaH2PO4, 2 CaCl2 and 1 MgCl2, pH
7.4 when bubbled with a 5% CO2 gas mixture balanced with
either 95% O2 or 95% N2 during short
periods (∼5 min) of optical recordings. The transient hypoxic
conditions dramatically reduced the sensitivity of neurons to photodynamic
damage with no detectable effect on the physiological conditions of nerve cells
supplied with phosphocreatine and ATP from the patch electrode3940. Somatic whole-cell recordings in current clamp or
voltage-clamp mode were made with 4–6 MΩ patch
pipettes using a Multiclamp 700B amplifier (Axon Instruments Inc., Union City,
CA, USA). Voltage-clamp recordings were made with series resistance compensation
set at 70%. Synaptic currents recorded were corrected for inadequate
space clamp using information from direct measurements of somatic voltage-clamp
errors23. The pipette solution contained (in mM): 120
K-gluconate, 3 KCl, 7 NaCl, 4 Mg-ATP, 0.3 Na-GTP, 20 HEPES and 14
tris-phosphocreatin (pH 7.3, adjusted with KOH) and 0.8 mM of the
voltage-sensitive dye JPW3028 (ref. 13). The
pharmacological agents were obtained from Tocris (TTX, Nimodipine, DL-AP5). The
somatic whole-cell recording data were not corrected for liquid junction
potential. In experiments using wild-type mice, an attempt was made to identify
layer 5 pyramidal cells with intact dendrites in one plane of focus close to the
surface of the slice (to minimize light scattering) using infrared differential
interference contrast (DIC) video microscopy. This approach is inefficient
because thin dendrites cannot be well resolved under DIC. Thus, even after
substantial experience, more than 50% of neurons loaded with the dye
were subsequently found to be badly chosen (dendrites cut or not running
parallel to the plane of focus). Selection of neurons with intact dendrites
positioned close to the surface of the slice
(<30 μm) was greatly facilitated using the Crym
transgenic mouse line expressing EGFP in a subset of layer 5 pyramidal neurons.
EGFP labelling allowed us to select appropriate neurons before dye loading by
visually inspecting a slice under 488 nm excitation of EGFP
fluorescence using spinning disk confocal microscopy mode at 5–20
frames per second (CSU-10 Yokogawa confocal scanner; Solamere Tech., Salt Lake
City, UT). Dendrites of individual nerve cells were readily visible under
fluorescence. EGFP fluorescence did not interfere with
voltage-sensitive dye signals due to the non-overlapping
emission spectra of these two fluorophores. In agreement with previous results
on cerebellar Purkinje cells41, neurons with EGFP fluorescence
had no detectable changes in electrical behaviour. The recordings were carried
out from spines on superficial basal dendrites at different distances from the
soma (range 30–120 μm). Labelling of pyramidal
neurons with the voltage-sensitive dye was carried out by free diffusion from a
somatic patch electrode in the whole-cell configuration. We used the most
successful voltage probe for intracellular application, JPW3028, a close
analogue of JPW1114 (ref. 42) with similar voltage
sensitivity available from Invitrogen as D6923. The electrode tips were first
filled with dye-free solution by applying negative pressure and then back filled
with the solution containing the voltage probe (0.8 mM). The patch
electrode was detached from the neuron by forming an outside-out patch after
staining was accomplished, as determined by measuring resting fluorescence
intensity from the soma. The optimal amount of staining was a compromise between
high level of fluorescence and the damage that can be caused by prolonged
dialysis of a neuron from the patch pipette. Following the staining period, the
preparation was typically incubated for an additional
1.5–2 h at room temperature to allow the voltage-sensitive
dye to spread into dendritic processes. Before optical recording, the cell was
re-patched to obtain electrical recording using an electrode filled with
dye-free intracellular solution
Optical recording
The recording setup was built around a stationary upright microscope
(AxioExaminer D1 with zoom tube (0.5–4 × ), Carl Zeiss
Microscopy LLC or Olympus BX51; Olympus Inc., USA) equipped with three camera
ports with a standard, high spatial resolution CCD camera for infrared DIC video
microscopy (CCD-300-RC, Dage-MTI, Michigan City, IN, USA), a fast data
acquisition camera with relatively low spatial resolution (80 × 80
pixels) and exceptionally low read noise (NeuroCCD-SM, RedShirtImaging LLC,
Decatur, GA, USA), and a high spatial resolution CCD camera (1,392 ×
1,024 pixels; Pixelfly-qe, PCO Imaging, Kelheim, Germany) mounted on a spinning
disc confocal scanner (Yokogawa CSU-10). The spinning disc scanner was used to
collect z-stacks of confocal images for detailed morphological
reconstruction of dendritic spines. For two-photon glutamate uncaging, an
additional dichroic mirror and IR blocking filter allowed introduction of
720 nm light (see below). Optical recording was carried out in the
wide-field epi-fluorescence microscopy mode because the superior spatial
resolution of confocal and two-photon fluorescence microscopy techniques are
difficult to utilize in Vm-imaging. Due to high fractional shot noise related to
the small number of emitted photons434445, these methods have
a poor S/N. The fluorescent image of the stained neuron was
projected by a water immersion objective onto the fast data acquisition CCD
positioned in the primary image plane. We used either a × 63/1.0
numerical aperture (NA), Carl Zeiss objective with a × 1.6 zoom tube
or a × 100/1.0 NA Olympus objective without zoom tube. A laser was
used as a source for excitation light in place of a conventional Xenon arc lamp
to increase the sensitivity of Vm-imaging by providing a monochromatic
excitation light at the red wing of the absorption spectrum to maximize Vm
sensitivity of the dye184346. In addition, the laser allowed
us to increase the intensity of the excitation light beyond the level that can
be achieved by an arc lamp. We used a 500 mW diode-pumped, continuous
wave laser emitting at 532 nm (MLL532, Changchun New Industries
Optoelectronics Tech. Co., Ltd., Changchun, China). The laser beam was coupled
to the microscope via a light guide and a single-port epifluorescence condenser
(TILL Photonics GmbH, Gräfelfing, Germany). Excitation light was
reflected to the preparation by a dichroic mirror (560 nm) and the
fluorescence light was filtered by a band pass emission filter (FF01-720;
720 nm blocking edge BrightLine, Semrock). A CCD frame (80
× 80 pixels) corresponded to a field of 18 ×
18 μm in the object plane.
Two-photon uncaging of glutamate
The voltage imaging setup was integrated with an ultra-fast pulsed
titanium-sapphire laser tuned to 720 nm for glutamate uncaging
(Chameleon Ultra, Coherent Inc.). The expanded beam of the laser was directed to
the scan mirror and passed to the back opening of the objective through a
dichroic mirror (FF705, Semrock) which reflected the voltage-sensitive dye
fluorescence to a CCD camera. The light intensity of the laser was controlled by
a Pockells cell (Model 350-80, Conoptics Inc.). The diffraction limited
720 nm stationary light spot was positioned in the centre of the
field of view. We found that commonly used MNI caged glutamate was possible to
use in combination with voltage-imaging if applied in high concentration
(∼20 mM) from an extracellular glass pipette. However, the
720 nm light intensities required for adequate release of glutamate
often resulted in significant bleaching of the membrane bound voltage-sensitive
dye in the spine head contaminating the eEPSP signal. Bath applied DNI-glutamateTFA (5 mM) provided by Femtonics KFT (Budapest, Hungary) has
∼7 times higher two-photon uncaging efficiency11 and was
more favourable to use. There were no differences in the results obtained with
the two compounds both in terms of spatial selectivity and the obtained current
responses. The spine head was positioned close
(∼0.5 μm) to the stationary uncaging site in the
centre of the field of view using a motorised movable top plate
(x–y resolution 0.02 μm,
Scientifica, UK) and an uncaging light pulse (∼10 mW,
0.45–0.5 ms) was applied. By fine tuning the intensity of
the uncaging light pulse, it was possible to closely approximate the amplitude
and the time course of miniature EPSCs.
Data analysis
Subthreshold eEPSP signals were recorded typically for 40 ms at a
frame rate of 2 kHz. AP signals were recorded for 10 ms at
5 kHz at near physiological temperature of
32–34 C° or at 2 kHz at room temperature
kept at 25–27 °C. Analysis and display of data were
carried out using the NeuroPlex programme (RedShirtImaging) written in IDL
(Exelis Visual Information Solutions, Boulder, CO) and custom Visual Basic
routines. Under low light conditions, background fluorescence becomes a
significant determinant of ΔF/F signal size. Raw data
were first corrected for this effect by subtracting the average background
fluorescence intensity determined from an unstained area on the slice.
Subsequently, signal alignment software was used to correct for temporal jitter
in AP initiation as well as for possible small movements of the preparation
during averaging47. In the temporal domain, AP signals were
aligned by cross-correlation of the electrically recorded APs in each trial to
the reference signal acquired at the start of averaging. In the spatial domain,
camera images were aligned in two dimensions offline by image cross-correlation
to compensate for possible small lateral movements of the preparation47. Correct focus of the image in the z-dimension was
verified before each individual trial; small adjustments were often necessary.
The spatially and temporally aligned signals were averaged and slow changes in
light intensity due to bleaching of the dye were corrected by dividing the data
by an appropriate dual exponential function derived from the recording trials
with no stimulation48. Dual exponential fitting requires an
algorithm for least-squares estimation of nonlinear parameters. We used the
Levenberg–Marquardt algorithm. The waveform of the AP signal was
reconstructed from a set of data points using Cubic Spline Interpolation, a
piecewise continuous curve passing through each data point47.
Subthreshold optical signals were calibrated on an absolute scale (in mV) by
normalizing to an optical signal from a bAP which has a known declining
amplitude along basal dendrites, as previously determined by patch-pipette
recordings1217. We experimentally confirmed (Supplementary Fig. 1) the previously reported
result1218 showing that this methods of calibration produce
the same results as normalizing signals to optical recordings corresponding to
long hyperpolarizing pulses delivered to the soma which attenuate relatively
little as they propagate along dendrites121719.The spine model, constructed with NEURON simulator49, represented
the spine as a cylinder (head) attached to the distal end of another cylinder
(neck) (equivalent electrical circuit in Supplementary Fig. 3). Anatomical properties of spines (neck diameter
0.18 μm; neck length 1 μm) were
adjusted to match the data from recent supra-resolution microscopy measurements
from living spines in brain slices73150. Resting potential
was −70 mV unless otherwise noted, and numerical
integration used NEURON's default implicit Euler method, with
dt 0.025 ms. In all simulations the spine head and neck
were treated as a single compartment which was quite sufficient for spatial
accuracy given the range of anatomical and biophysical properties that was
explored. The model parameters are based on ref. 12
with cytoplasmic resistivity (Ra)
100 Ω cm, specific membrane capacitance
(Cm)
1 μf cm−2 and
membrane leak conductance (g_pas)
1/20,000 S cm−2. To generate
synaptic current, we attached a biexponential conductance change synapse model
to the spine head with parameters τ1
0.2 ms, τ2 3 ms, peak
conductance 0.291 nS, reversal potential 0 mV to
approximate the experimentally determined current amplitude and time course
corresponding to a unitary EPSP amplitude in the soma in the range
0.2–0.8 mV (refs 21, 51, 52). Dendritic
diameters of the reconstructed layer 5 pyramidal neuron from the somatosensory
cortex were determined using confocal microscopy of live nerve cells labelled
with the dye used for voltage imaging (JPW3028). As this lipophilic dye
partitions into the membrane lipid bilayer, it was possible to accurately
determine dendritic diameters down to the diffraction limit of resolution
(∼0.3 μm) by recording the profile of light
intensity across dendritic branches (Supplementary Fig. 4). Accurate measurements of dendritic diameters
are critical because electrical role of spines is a function of the ratio of
spine neck resistance (Rneck) and dendritic input impedance
(Zdendrite). Because Zdendrite is a
steep function of diameter, errors in Zdendrite estimates can
lead to misinterpretation of both experimental and modelling results.
Morphologies of mouse neocortical pyramidal cells were obtained from
NeuroMorpho.org, specifically cell 070502-exp2-zB from the Krieger archive. The
models used in these simulations omitted the axon. Source code for these models
will be made available from ModelDB https://senselab.med.yale.edu/modeldb/.
Additional information
How to cite this article: Popovic, M. A. et al. Electrical behaviour of
dendritic spines as revealed by voltage imaging. Nat. Commun. 6:8436 doi:
10.1038/ncomms9436 (2015).
Authors: Balázs Chiovini; Gergely F Turi; Gergely Katona; Attila Kaszás; Dénes Pálfi; Pál Maák; Gergely Szalay; Mátyás Forián Szabó; Gábor Szabó; Zoltán Szadai; Szabolcs Káli; Balázs Rózsa Journal: Neuron Date: 2014-05-21 Impact factor: 17.173
Authors: Srinivas Kantevari; Stefan Passlick; Hyung-Bae Kwon; Matthew T Richers; Bernardo L Sabatini; Graham C R Ellis-Davies Journal: Chembiochem Date: 2016-04-09 Impact factor: 3.164
Authors: Simon R Schultz; Caroline S Copeland; Amanda J Foust; Peter Quicke; Renaud Schuck Journal: Proc IEEE Inst Electr Electron Eng Date: 2016-09-28 Impact factor: 10.961
Authors: Masoud Sepehri Rad; Yunsook Choi; Lawrence B Cohen; Bradley J Baker; Sheng Zhong; Douglas A Storace; Oliver R Braubach Journal: Biophys J Date: 2017-11-01 Impact factor: 4.033
Authors: Krishna Jayant; Jan J Hirtz; Ilan Jen-La Plante; David M Tsai; Wieteke D A M De Boer; Alexa Semonche; Darcy S Peterka; Jonathan S Owen; Ozgur Sahin; Kenneth L Shepard; Rafael Yuste Journal: Nat Nanotechnol Date: 2016-12-12 Impact factor: 39.213