Literature DB >> 26435183

Performance of local optimization in single-plane fluoroscopic analysis for total knee arthroplasty.

A H Prins1, B L Kaptein2, B C Stoel3, D J P Lahaye4, E R Valstar5.   

Abstract

Fluoroscopy-derived joint kinematics plays an important role in the evaluation of knee prostheses. Fluoroscopic analysis requires estimation of the 3D prosthesis pose from its 2D silhouette in the fluoroscopic image, by optimizing a dissimilarity measure. Currently, extensive user-interaction is needed, which makes analysis labor-intensive and operator-dependent. The aim of this study was to review five optimization methods for 3D pose estimation and to assess their performance in finding the correct solution. Two derivative-free optimizers (DHSAnn and IIPM) and three gradient-based optimizers (LevMar, DoNLP2 and IpOpt) were evaluated. For the latter three optimizers two different implementations were evaluated: one with a numerically approximated gradient and one with an analytically derived gradient for computational efficiency. On phantom data, all methods were able to find the 3D pose within 1mm and 1° in more than 85% of cases. IpOpt had the highest success-rate: 97%. On clinical data, the success rates were higher than 85% for the in-plane positions, but not for the rotations. IpOpt was the most expensive method and the application of an analytically derived gradients accelerated the gradient-based methods by a factor 3-4 without any differences in success rate. In conclusion, 85% of the frames can be analyzed automatically in clinical data and only 15% of the frames require manual supervision. The optimal success-rate on phantom data (97% with IpOpt) on phantom data indicates that even less supervision may become feasible.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Fluoroscopic analysis; Optimization; Pose estimation; Shape matching

Mesh:

Year:  2015        PMID: 26435183     DOI: 10.1016/j.jbiomech.2015.09.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  1 in total

1.  Influence of the Anterolateral Ligament on Knee Laxity: A Biomechanical Cadaveric Study Measuring Knee Kinematics in 6 Degrees of Freedom Using Dynamic Radiostereometric Analysis.

Authors:  Emil Toft Nielsen; Kasper Stentz-Olesen; Sepp de Raedt; Peter Bo Jørgensen; Ole Gade Sørensen; Bart Kaptein; Michael Skipper Andersen; Maiken Stilling
Journal:  Orthop J Sports Med       Date:  2018-08-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.