Weijun Kong1, Xiaofei Zhang2, Honghong Shen2, Zhen Ou-Yang3, Meihua Yang4.
Abstract
A sensitive, reproducible and accurate gas chromatography-electron capture detection (GC-ECD) method was developed for simultaneous determination of T-2 and HT-2 toxins in Chinese herbal medicines (CHMs) and related products after immunoaffinity column (IAC) clean-up and pre-column derivatization with N-heptafluoro-butyryl imidazole (HFBI). Then, gas chromatography-spectrometry spectrometer (GC-MS) was applied to confirm the positive results and interfering peaks. The limits of detection (LODs) for T-2 and HT-2 toxins were 1.88 and 0.47ng/g, and the recoveries for different CHMs ranged from 89.2% to 99.1% with relative standard deviation (RSD) <6.0% for T-2 and from 85.9% to 99.0% with RSD <8.8% for HT-2 toxin, respectively. The validated method was successfully applied for the determination of T-2 and HT-2 toxins in 89 Chinese herbal medicines and 10 related products from various sources, where it was found that T-2 and HT-2 toxins were not detected in any of the tested samples. These results were reliable by confirmation using GC-MS. Some unknown peaks were interfering peaks not the target toxins. CrownEntities:
Keywords: Chinese herbal medicine; GC-ECD; GC–MS; Method validation; T-2 and HT-2 toxins
Mesh:
Substances:
Year: 2011 PMID: 26434334 DOI: 10.1016/j.foodchem.2011.10.073
Source DB: PubMed Journal: Food Chem ISSN: 0308-8146 Impact factor: 7.514