Literature DB >> 2642398

Characteristics of flow-mediated brachial artery vasodilation in human subjects.

L I Sinoway1, C Hendrickson, W R Davidson, S Prophet, R Zelis.   

Abstract

In an effort to determine whether arterial conductance vessels dilate in response to increased blood flow stimuli, brachial artery area (cm2) and diameter (cm) were derived by simultaneous measurement of forearm blood flow (ml/min.100 ml) and brachial artery blood flow velocity (cm/sec) following the release of arterial occlusion. Measurements were made at rest and at the time of maximal flow after the release of graded periods of forearm arterial occlusion (20 seconds to 10 minutes). These studies showed a graded large vessel dilation following occlusions of up to 1 minute (baseline diameter, 0.33 +/- 0.01; after 1 minute occlusion, 0.45 +/- 0.02 cm; p less than 0.05) after which time diameter plateaued (after 10 minutes of occlusion, 0.48 +/- 0.02 cm). In addition, the time course of diameter and flow changes after 3 minutes of arterial occlusion were examined. Flow was maximal at 5 seconds but diameter was maximal at 15-30 seconds after release. Furthermore, the half time for the return of diameter to baseline was longer than that for blood flow. We also measured the diameter after forearm heating (42 degrees C) and noted a substantial increase in diameter (before heating, 0.32 +/- 0.01; after heating, 0.39 +/- 0.02 cm; p less than 0.05). Finally, we applied pressure to the venous side of arteriovenous fistulae in five hemodialysis patients. This maneuver was associated with large reductions in forearm blood flow (baseline flow, 63.3 +/- 10.6; venous compression flow, 36.0 +/- 4.4 ml/min.100 ml; p less than 0.05) and a decrease in brachial artery size (baseline diameter, 0.63 +/- 0.07; venous compression diameter, 0.58 +/- 0.06 cm; p less than 0.05). We conclude that 1) the human brachial artery size changes in response to changes in blood flow, and 2) the maximal dilation occurs after maximal flow is noted. Although alternate explanations are possible for each of our observations, our results are most consistent with a flow-mediated, localized vasodilating process.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  1989        PMID: 2642398     DOI: 10.1161/01.res.64.1.32

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  17 in total

Review 1.  Venous occlusion plethysmography in cardiovascular research: methodology and clinical applications.

Authors:  I B Wilkinson; D J Webb
Journal:  Br J Clin Pharmacol       Date:  2001-12       Impact factor: 4.335

Review 2.  Assessment of flow-mediated dilation in humans: a methodological and physiological guideline.

Authors:  Dick H J Thijssen; Mark A Black; Kyra E Pyke; Jaume Padilla; Greg Atkinson; Ryan A Harris; Beth Parker; Michael E Widlansky; Michael E Tschakovsky; Daniel J Green
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-10-15       Impact factor: 4.733

Review 3.  Vascular Adaptation to Exercise in Humans: Role of Hemodynamic Stimuli.

Authors:  Daniel J Green; Maria T E Hopman; Jaume Padilla; M Harold Laughlin; Dick H J Thijssen
Journal:  Physiol Rev       Date:  2017-04       Impact factor: 37.312

4.  The effect of oral antioxidants on brachial artery flow-mediated dilation following 5 and 10 min of ischemia.

Authors:  Ryan A Harris; Steven K Nishiyama; D Walter Wray; Vince Tedjasaputra; Damian M Bailey; Russell S Richardson
Journal:  Eur J Appl Physiol       Date:  2009-08-11       Impact factor: 3.078

5.  A real-time device for converting Doppler ultrasound audio signals into fluid flow velocity.

Authors:  Michael D Herr; Cynthia S Hogeman; Dennis W Koch; Anandi Krishnan; Afsana Momen; Urs A Leuenberger
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-02-19       Impact factor: 4.733

6.  Pulse wave amplitude is associated with brachial artery diameter: implications for gender differences in microvascular function.

Authors:  Kevin S Heffernan; Richard H Karas; Paula J Mooney; Ayan R Patel; Jeffrey T Kuvin
Journal:  Vasc Med       Date:  2009-12-21       Impact factor: 3.239

7.  Non-invasive measurement of endothelial function: effect on brachial artery dilatation of graded endothelial dependent and independent stimuli.

Authors:  P Leeson; S Thorne; A Donald; M Mullen; P Clarkson; J Deanfield
Journal:  Heart       Date:  1997-07       Impact factor: 5.994

8.  Transient stop-flow arm arterial-venous equilibrium pressure measurement: determination of precision of the technique.

Authors:  Hollmann D Aya; Andrew Rhodes; Nick Fletcher; R Michael Grounds; Maurizio Cecconi
Journal:  J Clin Monit Comput       Date:  2015-03-07       Impact factor: 2.502

9.  Chronic transfusion therapy improves but does not normalize systemic and pulmonary vasculopathy in sickle cell disease.

Authors:  Jon A Detterich; Roberta M Kato; Miklos Rabai; Herbert J Meiselman; Thomas D Coates; John C Wood
Journal:  Blood       Date:  2015-06-02       Impact factor: 22.113

Review 10.  Effects of Exercise on Vascular Function, Structure, and Health in Humans.

Authors:  Daniel J Green; Kurt J Smith
Journal:  Cold Spring Harb Perspect Med       Date:  2018-04-02       Impact factor: 6.915

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.