Literature DB >> 26422307

Online post-column solvent assisted and direct solvent-assisted electrospray ionization for chiral analysis of propranolol enantiomers in plasma samples.

Hatem Elmongy1, Hytham Ahmed2, Abdel-Aziz Wahbi3, Hirsh Koyi4, Mohamed Abdel-Rehim5.   

Abstract

An Online post-column solvent-assisted ionization (OPSAI) method was developed for enhancing the ionization of the beta-blocker propranolol utilizing normal phase LC-MS/MS. Solvent-assisted electrospray ionization (SAESI) was studied by the introduction of the assistant solvents A: 0.5% Formic acid in Isopropanolol, B: 0.5% Formic acid in Isopropanolol-Water (1:1), and C: 0.5% Formic acid in water into the electrospray ionization chamber using a spray needle. Analyte molecules can be directly ionized by the aid of the assistant solvent spray. Both methods were applied to the chiral separation of propranolol enantiomers using normal phase analysis on cellulose-based chiral column. Interestingly, both methods are easy to handle and offer a wide range of assistant solvents that can be used in order to gain the optimum ionization of the analyte molecules. The both methods considerably improved the analyte signal and the peak area greatly increased. The propranolol average signal-to-noise (S/N) ratio was enhanced from 26±1 and 42±1 to 2341±61 and 1725±29 for R-propranolol and S-propranolol, respectively, when the post-column solvent method (OPSAI) was used with isopropanol-assistant solvent (A). While in case of solvent-assisted electrospray ionization method (SAESI) signal was enhanced from 26±1 and 42±1 to 2223±72 and 2155±58 for R-propranolol and S-propranolol, respectively, with water as an assistant solvent. The limit of detection was 10ng/mL and the method was linear in the range 50-2000ng/mL. The NPLC-MS method was applied for the determination of propranolol enantiomers in human plasma after microextraction by packed C18 sorbent.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chiral separation; Electrospray ionization; Normal phase LC; Propranolol Enantiomers; Tandem mass spectrometry

Mesh:

Substances:

Year:  2015        PMID: 26422307     DOI: 10.1016/j.chroma.2015.09.051

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  On-chip mass spectrometric analysis in non-polar solvents by liquid beam infrared matrix-assisted laser dispersion/ionization.

Authors:  Raphael D Urban; Tillmann G Fischer; Ales Charvat; Konstantin Wink; Benjamin Krafft; Stefan Ohla; Kirsten Zeitler; Bernd Abel; Detlev Belder
Journal:  Anal Bioanal Chem       Date:  2021-01-21       Impact factor: 4.142

2.  Lithium fluoride recovery from cathode material of spent lithium-ion battery.

Authors:  Ying Zheng; Wei Song; Wen-Ting Mo; Lai Zhou; Jian-Wen Liu
Journal:  RSC Adv       Date:  2018-02-28       Impact factor: 3.361

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.