J Cohn1, D Moaveni2, J Sznol3, J Ranasinghe2. 1. University of Miami Miller School of Medicine, Jackson Memorial Hospital, Miami, FL, USA. Electronic address: jhochman@med.miami.edu. 2. University of Miami Miller School of Medicine, Jackson Memorial Hospital, Miami, FL, USA. 3. University of Miami Public Health Sciences, Miami, FL, USA.
Abstract
BACKGROUND: A continuous spinal catheter is a reliable alternative to standard neuraxial techniques in obstetric anesthesia. Despite the potential advantages of intrathecal catheters, they remain underutilized due to fear of infection, nerve damage or post-dural puncture headache. In our tertiary care center, intrathecal catheters are either placed intentionally in high-risk obstetric patients or following inadvertent dural puncture using a 19-gauge macrocatheter passed through a 17-gauge epidural needle. METHODS: A retrospective review of 761 intrathecal catheters placed from 2001 to 2012 was conducted. An institutional obstetric anesthesia database was used to identify patients with intrathecal catheters. Medical records were reviewed for procedural details and complications. RESULTS: There were no serious complications, including meningitis, epidural or spinal abscess, hematoma, arachnoiditis, or cauda equina syndrome, associated with intrathecal catheters. The failure rates were 2.8% (3/108) for intentional placements and 6.1% (40/653) for placements following accidental dural puncture. The incidence of post-dural puncture headache was 41% (312/761) and the epidural blood patch rate was 31% (97/312). CONCLUSIONS: This review demonstrates that intrathecal catheters are dependable and an option for labor analgesia and surgical anesthesia for cesarean delivery. Serious long-lasting complications are rare.
BACKGROUND: A continuous spinal catheter is a reliable alternative to standard neuraxial techniques in obstetric anesthesia. Despite the potential advantages of intrathecal catheters, they remain underutilized due to fear of infection, nerve damage or post-dural puncture headache. In our tertiary care center, intrathecal catheters are either placed intentionally in high-risk obstetric patients or following inadvertent dural puncture using a 19-gauge macrocatheter passed through a 17-gauge epidural needle. METHODS: A retrospective review of 761 intrathecal catheters placed from 2001 to 2012 was conducted. An institutional obstetric anesthesia database was used to identify patients with intrathecal catheters. Medical records were reviewed for procedural details and complications. RESULTS: There were no serious complications, including meningitis, epidural or spinal abscess, hematoma, arachnoiditis, or cauda equina syndrome, associated with intrathecal catheters. The failure rates were 2.8% (3/108) for intentional placements and 6.1% (40/653) for placements following accidental dural puncture. The incidence of post-dural puncture headache was 41% (312/761) and the epidural blood patch rate was 31% (97/312). CONCLUSIONS: This review demonstrates that intrathecal catheters are dependable and an option for labor analgesia and surgical anesthesia for cesarean delivery. Serious long-lasting complications are rare.
Authors: Veerandra Koyyalamudi; Gurleen Sidhu; Elyse M Cornett; Viet Nguyen; Carmen Labrie-Brown; Charles J Fox; Alan D Kaye Journal: Curr Pain Headache Rep Date: 2016-02
Authors: Carol S Palackdkharry; Stephanie Wottrich; Erin Dienes; Mohamad Bydon; Michael P Steinmetz; Vincent C Traynelis Journal: PLoS One Date: 2022-09-30 Impact factor: 3.752
Authors: Fábio Farias de Aragão; Pedro Wanderley de Aragão; Carlos Alberto Martins; Karlla Fernanda Custódia Silva Leal; Alexandro Ferraz Tobias Journal: Braz J Anesthesiol Date: 2019-02-15