Fei Wang1, Sheng Liu, Le Qiu, Ben Ma, Jian Wang, Yong-Jie Wang, April Peszel, Xu-Lin Chen.
Abstract
Severe burn and infection to hands always involves the deep structures, such as tendons, joints, and bones. These wounds cannot be closed immediately and therefore creates a high risk for complication. We presented 9 cases with deep dermal burns to the dorsal of the hand (6 electrical burns and 3 thermal crush injuries) with wound infections in 2 cases. The vacuum-assisted closure system was used continuously until the flap reconstruction was performed. A random pattern and superthin abdominal wall skin flap-like glove was designed. The flap was transferred to the defected portion of the dorsum of the hand and resected from the abdominal wall about 3 weeks later. The flaps in 8 of the patients treated by this technique survived completely and partial necrosis of the distal flap occurred in 1 patient. The defect resolved after operative treatment and the function of the hands and fingers were successfully salvaged. All patients resulted in having a satisfactory aesthetic outcome with no or minor discomfort at the abdominal donor area. Integration of the vacuum-assisted closure system and the superthin abdominal wall glove-like flap reconstruction appeared to be successful and should be considered in patients with severely burned hands.Entities:
Mesh:
Year: 2015 PMID: 26418768 DOI: 10.1097/SAP.0000000000000602