Literature DB >> 26418753

Biocompatibility of common polyimides with human endothelial cells for a cardiovascular microsensor.

Peter Starr1,2, C Mauli Agrawal2, Steven Bailey1,2.   

Abstract

The cardiovasculature is an emerging niche for polyimide microdevices, yet the biocompatibility of polyimides with human endothelial cells has not been reported in the literature. In this study, we have evaluated an experimental polyimide-based pressure sensor for biological safety to determine its suitability for intravascular operation by using an in vitro model of human endothelium, following ISO 10993-5 protocols for extract tests and direct contact tests. First, SV-HCEC cells were incubated with extracts derived from common microfabrication polyimides utilized in the transducer (PMDA-ODA, BPDA-PPD, and a proprietary thermoplastic adhesive), and then labeled with selective probes to evaluate the effect of the polyimides on mitochondria and cell viability. Flow cytometry analysis showed that incubation of SV-HCECs with polyimide extracts resulted in no significant change in mitochondrial membrane potential (detected by JC-1) or apoptotic (annexin V) and necrotic (propidium iodide) cell death, when compared to incubation with extracts of high-density polyethylene (HDPE) and untreated cells used as negative controls. Second, primary human endothelial cells were incubated in direct contact with the completed sensor and then labeled with selective probes for live-dead analysis (calcein-AM, ethidium homodimer-1). Endothelial cells showed no loss of viability when compared to negative controls. Combined, the studies show no significant change in early markers of stress or more strict markers of viability in endothelial cells treated with the polyimides tested. We conclude that these common microfabrication polyimides and the derived sensor are not cytotoxic to human endothelial cells, the primary cell type that cardiovascular sensors will contact in vivo.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  biocompatibility; cardiovascular; microfabrication; polyimides; sensor

Mesh:

Substances:

Year:  2015        PMID: 26418753     DOI: 10.1002/jbm.a.35578

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  6 in total

1.  The preparation of heparin-like hyperbranched polyimides and their antithrombogenic, antibacterial applications.

Authors:  Qing Li; Jing Li; Guangfu Liao; Zushun Xu
Journal:  J Mater Sci Mater Med       Date:  2018-07-28       Impact factor: 3.896

2.  First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity-Part 1: Biocompatibility Testing.

Authors:  Aura Kullmann; Debra Kridner; Steve Mertens; Mark Christianson; Dave Rosa; Camilo A Diaz-Botia
Journal:  Front Neurosci       Date:  2022-04-29       Impact factor: 5.152

Review 3.  Microfabrication for Drug Delivery.

Authors:  Brendan Koch; Ilaria Rubino; Fu-Shi Quan; Bongyoung Yoo; Hyo-Jick Choi
Journal:  Materials (Basel)       Date:  2016-08-01       Impact factor: 3.623

4.  Multichannel optrodes for photonic stimulation.

Authors:  Yingyue Xu; Nan Xia; Michelle Lim; Xiaodong Tan; Minh Ha Tran; Erin Boulger; Fei Peng; Hunter Young; Christoph Rau; Alexander Rack; Claus-Peter Richter
Journal:  Neurophotonics       Date:  2018-10-23       Impact factor: 3.593

Review 5.  Biocompatibility of Polyimides: A Mini-Review.

Authors:  Catalin P Constantin; Magdalena Aflori; Radu F Damian; Radu D Rusu
Journal:  Materials (Basel)       Date:  2019-09-27       Impact factor: 3.623

Review 6.  Near-infrared stimulation of the auditory nerve: A decade of progress toward an optical cochlear implant.

Authors:  Philip D Littlefield; Claus-Peter Richter
Journal:  Laryngoscope Investig Otolaryngol       Date:  2021-03-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.