Literature DB >> 26415205

Flexible Bioimpedance Sensor for Label-Free Detection of Cell Viability and Biomass.

Renny Edwin Fernandez, Elise Lebiga, Anil Koklu, Ahmet Can Sabuncu, Ali Beskok.   

Abstract

We introduce a flexible microfluidic bioimpedance sensor that is capable of detecting biomass and cell viability variations in a cell suspension. The sensor is developed on indium tin oxide (ITO) coated polyethylene terephthalate (PET) substrate and is devoid of gold, silicon, PDMS, or glass. In conjugation with a custom built PCB read-out module, the impedance characteristics of a cell suspension can be measured within one minute of sample introduction using liquid volumes less than 5 μL. The portable sensor system occupies very little bench space and has the potential to be developed as a disposable electrical bioimpedance probe for rapid detection of dielectric variations in a biological suspension. The sensor is designed to generate a differential impedance spectra exclusive to a cell suspension with a dual-electrode-pair system. The potential of the sensor to discriminate between live and heat treated Saccharomyces cerevisiae is demonstrated in this study. The disposable sensor along with the distance variation technique is touted to be an inexpensive alternative to some of the existing online disposable biomass detection probes and electrochemical sensors.

Entities:  

Mesh:

Year:  2015        PMID: 26415205     DOI: 10.1109/TNB.2015.2451594

Source DB:  PubMed          Journal:  IEEE Trans Nanobioscience        ISSN: 1536-1241            Impact factor:   2.935


  4 in total

1.  Dielectrophoresis assisted loading and unloading of microwells for impedance spectroscopy.

Authors:  Amin Mansoorifar; Anil Koklu; Ahmet C Sabuncu; Ali Beskok
Journal:  Electrophoresis       Date:  2017-03-21       Impact factor: 3.535

Review 2.  The design, fabrication, and applications of flexible biosensing devices.

Authors:  Meng Xu; Dora Obodo; Vamsi K Yadavalli
Journal:  Biosens Bioelectron       Date:  2018-10-13       Impact factor: 10.618

3.  Disposable aptamer-sensor aided by magnetic nanoparticle enrichment for detection of salivary cortisol variations in obstructive sleep apnea patients.

Authors:  Renny Edwin Fernandez; Yogeswaran Umasankar; Pandiaraj Manickam; Jeffrey C Nickel; Laura R Iwasaki; Burt K Kawamoto; Kristen C Todoki; JoAnna M Scott; Shekhar Bhansali
Journal:  Sci Rep       Date:  2017-12-21       Impact factor: 4.379

4.  Smart Bioimpedance Spectroscopy Device for Body Composition Estimation.

Authors:  David Naranjo-Hernández; Javier Reina-Tosina; Laura M Roa; Gerardo Barbarov-Rostán; Nuria Aresté-Fosalba; Alfonso Lara-Ruiz; Pilar Cejudo-Ramos; Francisco Ortega-Ruiz
Journal:  Sensors (Basel)       Date:  2019-12-21       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.