Literature DB >> 26415199

Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System.

Dangdang Shao, Chenbin Liu, Francis Tsow, Yuting Yang, Zijian Du, Rafael Iriya, Hui Yu, Nongjian Tao.   

Abstract

We present a noncontact method to monitor blood oxygen saturation (SpO2). The method uses a CMOS camera with a trigger control to allow recording of photoplethysmography (PPG) signals alternatively at two particular wavelengths, and determines the SpO2 from the measured ratios of the pulsatile to the nonpulsatile components of the PPG signals at these wavelengths. The signal-to-noise ratio (SNR) of the SpO2 value depends on the choice of the wavelengths. We found that the combination of orange (λ = 611 nm) and near infrared (λ = 880 nm) provides the best SNR for the noncontact video-based detection method. This combination is different from that used in traditional contact-based SpO 2 measurement since the PPG signal strengths and camera quantum efficiencies at these wavelengths are more amenable to SpO2 measurement using a noncontact method. We also conducted a small pilot study to validate the noncontact method over an SpO2 range of 83%-98%. This study results are consistent with those measured using a reference contact SpO2 device ( r = 0.936, ). The presented method is particularly suitable for tracking one's health and wellness at home under free-living conditions, and for those who cannot use traditional contact-based PPG devices.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26415199     DOI: 10.1109/TBME.2015.2481896

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  17 in total

1.  Motion robust remote photoplethysmography in CIELab color space.

Authors:  Yuting Yang; Chenbin Liu; Hui Yu; Dangdang Shao; Francis Tsow; Nongjian Tao
Journal:  J Biomed Opt       Date:  2016-11-01       Impact factor: 3.170

2.  Moving Electrons Purposefully through Single Molecules and Nanostructures: A Tribute to the Science of Professor Nongjian Tao (1963-2020).

Authors:  Erica S Forzani; Huixin He; Joshua Hihath; Stuart Lindsay; Reginald M Penner; Shaopeng Wang; Bingqian Xu
Journal:  ACS Nano       Date:  2020-09-17       Impact factor: 15.881

3.  Developing a Wireless, High Precision and Processing Speed Pulse Monitoring Headset Using Photoplethysmography.

Authors:  Yunhui Jiang; Jian Tang; Xiaoliang Wang; Chao Shen
Journal:  IEEE J Transl Eng Health Med       Date:  2017-10-20       Impact factor: 3.316

4.  Simultaneous Monitoring of Ballistocardiogram and Photoplethysmogram Using a Camera.

Authors:  Dangdang Shao; Francis Tsow; Chenbin Liu; Yuting Yang; Nongjian Tao
Journal:  IEEE Trans Biomed Eng       Date:  2016-06-29       Impact factor: 4.538

5.  New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

Authors:  Mark van Gastel; Sander Stuijk; Gerard de Haan
Journal:  Sci Rep       Date:  2016-12-07       Impact factor: 4.379

6.  Combination of near-infrared and thermal imaging techniques for the remote and simultaneous measurements of breathing and heart rates under sleep situation.

Authors:  Menghan Hu; Guangtao Zhai; Duo Li; Yezhao Fan; Huiyu Duan; Wenhan Zhu; Xiaokang Yang
Journal:  PLoS One       Date:  2018-01-05       Impact factor: 3.240

7.  A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine.

Authors:  Paul C-P Chao; Pei-Yu Chiang; Yung-Hua Kao; Tse-Yi Tu; Chih-Yu Yang; Der-Cherng Tarng; Chin-Long Wey
Journal:  Sensors (Basel)       Date:  2018-11-09       Impact factor: 3.576

8.  The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare.

Authors:  Hyun Jae Baek; JaeWook Shin; Jaegeol Cho
Journal:  J Healthc Eng       Date:  2018-10-21       Impact factor: 2.682

9.  Psycho-Physiological Effects of a Peony-Viewing Program on Middle-Aged and Elderly Individuals at Different Phenological Stages.

Authors:  Ren-Lin Zhao; Gang Zhang; Xi Wang; Bo-Tong Zhang; Li-Na Guo; Li-Xin Niu; Yan-Long Zhang
Journal:  Int J Environ Res Public Health       Date:  2019-02-02       Impact factor: 3.390

10.  Calibration of Contactless Pulse Oximetry.

Authors:  Wim Verkruysse; Marek Bartula; Erik Bresch; Mukul Rocque; Mohammed Meftah; Ihor Kirenko
Journal:  Anesth Analg       Date:  2017-01       Impact factor: 5.108

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.