Literature DB >> 26412004

Fracture resistance of monolithic zirconia crowns with different occlusal thicknesses in implant prostheses.

Ting-Hsun Lan1, Pao-Hsin Liu2, Mitch M C Chou3, Huey-Er Lee4.   

Abstract

STATEMENT OF PROBLEM: The use of monolithic zirconia crowns in implant prostheses is increasing, especially when the interdental space is insufficient. However, fractures have been reported in clinical practice.
PURPOSE: The purpose of this study was to determine the minimal thickness of a complete zirconia crown used for an implant prosthesis in the posterior dental region.
MATERIAL AND METHODS: Fifty complete zirconia crowns were produced using a computer-aided design/computer-aided manufacturing technique. In each group, 5 crowns of varying thicknesses (0.4, 0.5, 0.6, 0.7, and 0.8 mm) were subjected to cycles of vertical and 10-degree oblique compressive loading at 5 Hz and 300 N in a servohydraulic testing machine. Five finite element models comprising 5 different occlusal thicknesses (0.4, 0.5, 0.6, 0.7, and 0.8 mm) were simulated at 2 loading angles (0 and 10 degrees) and 3 loading forces (300, 500, and 800 N). Data were statistically analyzed, and fracture patterns were observed with a scanning electron microscope.
RESULTS: Cyclic loading tests revealed that the fracture resistance of the specimens was positively associated with prosthesis thickness (P<.01). Low von Mises stress values were obtained for prostheses with a minimal thickness of 0.7 mm under varying loading directions and forces.
CONCLUSIONS: Zirconia prostheses with a minimal thickness of 0.7 mm had a high fracture resistance and the lowest stress values. Therefore, dentists and laboratory technicians should carefully choose the optimum thickness of zirconia prostheses.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26412004     DOI: 10.1016/j.prosdent.2015.06.021

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

Review 1.  Current status on lithium disilicate and zirconia: a narrative review.

Authors:  Fernando Zarone; Maria Irene Di Mauro; Pietro Ausiello; Gennaro Ruggiero; Roberto Sorrentino
Journal:  BMC Oral Health       Date:  2019-07-04       Impact factor: 2.757

2.  3D FEA Study On Implant Threading Role on Selection of Implant and Crown Materials.

Authors:  Ahmad Mohamad Wazeh; Mohamed I El-Anwar; Rami M Galal Atia; Rana Mohammed Mahjari; Sara Abdulelah Linga; Linah Mujeeb Alhaq Al-Pakistani; Salah Abdulazim Yousief
Journal:  Open Access Maced J Med Sci       Date:  2018-09-11

3.  Patient Satisfaction with Implant-Supported Monolithic and Partially Veneered Zirconia Restorations.

Authors:  Paolo De Angelis; Giulio Gasparini; Edoardo Rella; Silvio De Angelis; Cristina Grippaudo; Antonio D'Addona; Paolo Francesco Manicone
Journal:  Biomed Res Int       Date:  2021-02-06       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.